J-STD-001 SOLDERING PRACTICES
MODULE 1 AND 2 TEST QUESTIONS AND
CORRECT DETAILED ANSWERS 100%
CORRECT | NEW 2025
Recertification of Certified IPC Specialists _____. - ANSWER✅ May be
administered by any currently certified Master IPC Trainer or Certified IPC Trainer
Which of the following IPC product classifications would include products where
continued performance and extended life is required, and for which uninterrupted
service is desired but not critical and typically the end-use environment would not
cause failures? - ANSWER✅ Class 2- Dedicated Service Electronic Products
All IPC certification programs for MIT, CIT, and CIS require recertification after
what period of time? - ANSWER✅ 2 years
Illumination at the surface of workstations should be at least_____. - ANSWER✅
1000 lm/m²
All instructors, operators and all inspection personnel __________ be proficient in
the tasks to be performed. - ANSWER✅ Shall
A solder connection that exhibits poor wetting and that is characterized by a
grayish porous appearance defines? - ANSWER✅ Cold solder connection
, The word "shall" in this document invokes a requirement for manufacturers of
________ of product, and failure to comply with the requirement is a
noncompliance to this standard. - ANSWER✅ all classes
Certified IPC Specialist Training programs will train, test and certify in the correct
application of the criteria for which class(es) of products? - ANSWER✅ All 3
product classes
One of the goals of the IPC training programs is to _____. - ANSWER✅ Provide an
understanding of accept/reject criteria.
The recommended practices for handling electronic assemblies state that there
must not be any eating, drinking or ________ in the work area. - ANSWER✅ Use
of tobacco products.
A CIS candidate may challenge any of the workmanship skills training programs by
_____. - ANSWER✅ Completing the same requirements of those taking the
classroom course.
Any violation of minimum electrical clearance would be considered __________
condition for all three classes? - ANSWER✅ a Defect
Certified IPC Trainers are authorized to grant Certified IPC Specialist's a single
extension of certification up to _____days. - ANSWER✅ 90
The magnification power inspection range for a soldered connection with a land
width of 0.35mm is_____. - ANSWER✅ 7.5X to 10X
MODULE 1 AND 2 TEST QUESTIONS AND
CORRECT DETAILED ANSWERS 100%
CORRECT | NEW 2025
Recertification of Certified IPC Specialists _____. - ANSWER✅ May be
administered by any currently certified Master IPC Trainer or Certified IPC Trainer
Which of the following IPC product classifications would include products where
continued performance and extended life is required, and for which uninterrupted
service is desired but not critical and typically the end-use environment would not
cause failures? - ANSWER✅ Class 2- Dedicated Service Electronic Products
All IPC certification programs for MIT, CIT, and CIS require recertification after
what period of time? - ANSWER✅ 2 years
Illumination at the surface of workstations should be at least_____. - ANSWER✅
1000 lm/m²
All instructors, operators and all inspection personnel __________ be proficient in
the tasks to be performed. - ANSWER✅ Shall
A solder connection that exhibits poor wetting and that is characterized by a
grayish porous appearance defines? - ANSWER✅ Cold solder connection
, The word "shall" in this document invokes a requirement for manufacturers of
________ of product, and failure to comply with the requirement is a
noncompliance to this standard. - ANSWER✅ all classes
Certified IPC Specialist Training programs will train, test and certify in the correct
application of the criteria for which class(es) of products? - ANSWER✅ All 3
product classes
One of the goals of the IPC training programs is to _____. - ANSWER✅ Provide an
understanding of accept/reject criteria.
The recommended practices for handling electronic assemblies state that there
must not be any eating, drinking or ________ in the work area. - ANSWER✅ Use
of tobacco products.
A CIS candidate may challenge any of the workmanship skills training programs by
_____. - ANSWER✅ Completing the same requirements of those taking the
classroom course.
Any violation of minimum electrical clearance would be considered __________
condition for all three classes? - ANSWER✅ a Defect
Certified IPC Trainers are authorized to grant Certified IPC Specialist's a single
extension of certification up to _____days. - ANSWER✅ 90
The magnification power inspection range for a soldered connection with a land
width of 0.35mm is_____. - ANSWER✅ 7.5X to 10X