2024/2025

NEC 2017 Questions and Answers 100% Solved How many volt-amperes are calculated per 1ft of show window? A) 50 B) 100 C) 150, or D) 200 Correct Answ_D) 200 220.14(G)(2) Metal enclosures for over current devices in damp or wet locations, shall be mounted so that there is at least a ________in. air gap between the wall and the other support surface. A) 1/8 B) 1/4 C) 3/8, or D) 1/2. Correct Answ_B) 1/4 240.32, 312.2

Show more Read less
Institution
NEC ...
Course
NEC ...

Content preview

NEC 2017 Questions and Answers 100%
Solved

How many volt-amperes are calculated per 1ft of show window?


A) 50 B) 100 C) 150, or D) 200 Correct Answ_D) 200 220.14(G)(2)




Metal enclosures for over current devices in damp or wet locations, shall be mounted so that

there is at least a ________in. air gap between the wall and the other support surface.


A) 1/8 B) 1/4 C) 3/8, or D) 1/2. Correct Answ_B) 1/4 240.32, 312.2




A lamp holder is supplied by a circuit over 20 amps. What type of lamp holder is permitted?


A) Medium base B) Light duty C) Heavy duty, or D) Extra heavy duty. Correct Answ_C)

Heavy duty 210.21(A)




General lighting loads by occupancy dwelling units require a minimum of ______ volt-amperes

per sq. ft.


A) 3 B) 4 C) 5 or D) 8 Correct Answ_A) 3 volt amperes Table 220.12

,Surge arresters are grounded at the arrester grounding terminal. If the arrester ground conductor

is ran in a metal enclosure, the grounding conductor MUST be bonded at ______end(s) of the

enclosure.


A) one B) the supply C) the load D) both Correct Answ_D) Both 280.25




How many receptacle outlets are required above a show window that is 18ft wide?


A) 2 B) 3 C)4 or D) none of the above Correct Answ_A) 2 210.62




Concrete encased grounding electrodes shall have a minimum length of _______ft and minimum

diameter of ________in.


A) 10ft and 1/2 inch B) 15ft and 5/8 inch C) 20ft and 1/2 inch, or D) 25ft and 5/8 in. Correct

Answ_C) 20 feet and 1/2 inch diameter. 250.52(A)(3)(1)




A grounding electrode shall be installed so ______ft in contact with soil. (Earth)


A) 6 B) 8 C) 10 or D) 15 Correct Answ_8 ft 250.53(G)




What is the maximum combined length of FMC, FMT, and LFMC in the same ground-fault

current path.


A) 4ft B) 5ft C) 6ft D) 10ft Correct Answ_250.118(5)(C)

, Appliance outlets (such as electric dryers) shall be installed within _____ft of intended appliance

location.


A) 2 B) 6 C) 8 or D)10 Correct Answ_B) 6 210.50(C)




Overhead service drops shall NOT have conductors smaller than?


A) #8 Copper B) #4 Aluminium C) #6 Copper, or D) #4 Copper Correct Answ_A) 8AWG

copper 230.23(B)




A 10ft section of ______ is not considered a grounding conductor.


A) AC Cable B) Cable tray C) FMC D) Auxiliary gutter Correct Answ_C) FMC

250.118(5)(C)




Service entrance conductors in a raceway beneath a building, under at least _____ inches of

concrete is considered to be "outside" the building.


A) 2 B) 4 C) 8 D) 12 Correct Answ_A) 2 230.6(1)




The two small appliance branch circuits in dwellings need to be calculated at _______volt

amperes. (Watts)

Written for

Institution
NEC ...
Course
NEC ...

Document information

Uploaded on
March 29, 2025
Number of pages
23
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
ARVEX

Also available in package deal

Thumbnail
Package deal
NEC EXAM PACK WITH COMPLETE SOLUTIONS
-
3 2025
$ 41.47 More info

Get to know the seller

Seller avatar
ARVEX stuvia
View profile
Follow You need to be logged in order to follow users or courses
Sold
7
Member since
10 months
Number of followers
0
Documents
2867
Last sold
2 months ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions