Minnesota Special Boiler License EXAM 2025/2026 COMPLETE QUESTIONS WITH CORRECT DETAILED ANSWERS || 100% GUARANTEED PASS &lt;LATEST VERSION&gt; 1. High Pressure Boiler - ANSWER Above 15psi steam & 160psi water pressure 2. After blowing down column and glass the water should return how? - ANSWER Quickly 3. When entering a steam boiler room what is the first thing an operator should do? - ANSWER Check water level 4. What type of safety valve is required - ANSWER A.S.M.E. approved direct spring loaded 5. When operating a boiler what is most important? - ANSWER Safety 6. When draining a boiler how should you cool it? - ANSWER Slowly 7. How does a low water cut off protect a boiler? - ANSWER Shuts off fuel in case of low water 8. State of MN requires boilers to be inspected how often? - ANSWER Depends if it is steam or hot water. 9. How long do you vent a boiler before starting fires? - ANSWER 4 air exchanges 10. What is the rapid burning of fuel and oxygen resulting in heat? - ANSWER Combustion 11. What is the purpose of bottom blowdowns besides removing sludge? - ANSWER To drain the boiler 12. What turns a hot water boiler on based on water temperature? - ANSWER An aquastat 13. Steam boilers under 200 horsepower must have low water cutoff tested how often? - ANSWER When in operation and on low fire 14. What is an indication of a gauge glass not working properly? - ANSWER No movement in the water glass 15. When comparing a hot water boiler to a steam boiler, what does a hot water boiler have that a steam boiler does not? - ANSWER Circulating pump, expansion tank, and an aquastat 16. What is the device that will shut the boiler down in case of low water? - ANSWER Low water cutoff 17. What must be displayed in a boiler room? - ANSWER Current license and log book 18. According to national board code, safety valves are to be tested how often? - ANSWER 90 days 19. What device removes air and condensate? - ANSWER Steam trap 20. What must be done after a hot water boiler has been drained, cleaned and refilled? - ANSWER Remove air 21. What can a special engineer operate? - ANSWER In charge of 50 horsepower. Shift operator 100 horsepower high or low pressure 22. What are the three main types of boilers? - ANSWER Fire tube, water tube, cast iron sectional 23. How much experience is required for a special license? - ANSWER No experience 24. At a minimum, what is required in a log book? - ANSWER Who, what and when 25. When in operation a 40 horsepower boiler may be left unattended for how long? - ANSWER 24 hours 26. What method of testing low water cut off most accurately simulates low water? - ANSWER Shutting off the feed pump and feeder valve supply and blowing down low water cutoff 27. How do we know if we are using and approved safety valve for a steam boiler or a safety relief valve for a hot water boiler? - ANSWER A spring loaded direct acting safety valve or safety relief valve. 28. Before testing a low water fuel cut-out what must be done? - ANSWER The burner must be on. 29. Heat can be transferred in how many ways? - ANSWER Three. 30. Aqua stats work by sensing: - ANSWER Temperature. 31. Name the different ways heat can be transferred and give a definition of each way. - ANSWER Radiation, Conduction, Convection 32. How many types of boilers are there? - ANSWER Three: Fire tube, Water tube, Cast iron sectional 33. What type of boiler can be made larger? - ANSWER Cast Iron sectional 34. What type of boiler has the water surrounding the tubes? - ANSWER Fire tube

Show more Read less
Institution
Minnesota Special Boiler License
Course
Minnesota Special Boiler License











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Minnesota Special Boiler License
Course
Minnesota Special Boiler License

Document information

Uploaded on
March 14, 2025
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Minnesota Special Boiler License
EXAM 2025/2026 COMPLETE QUESTIONS
WITH CORRECT DETAILED ANSWERS ||
100% GUARANTEED PASS
<LATEST VERSION>



1. High Pressure Boiler - ANSWER ✓ Above 15psi steam & 160psi water
pressure

2. After blowing down column and glass the water should return how? -
ANSWER ✓ Quickly

3. When entering a steam boiler room what is the first thing an operator should
do? - ANSWER ✓ Check water level

4. What type of safety valve is required - ANSWER ✓ A.S.M.E. approved
direct spring loaded

5. When operating a boiler what is most important? - ANSWER ✓ Safety

6. When draining a boiler how should you cool it? - ANSWER ✓ Slowly

7. How does a low water cut off protect a boiler? - ANSWER ✓ Shuts off fuel
in case of low water

8. State of MN requires boilers to be inspected how often? - ANSWER ✓
Depends if it is steam or hot water.

9. How long do you vent a boiler before starting fires? - ANSWER ✓ 4 air
exchanges

,10.What is the rapid burning of fuel and oxygen resulting in heat? - ANSWER
✓ Combustion

11.What is the purpose of bottom blowdowns besides removing sludge? -
ANSWER ✓ To drain the boiler

12.What turns a hot water boiler on based on water temperature? - ANSWER ✓
An aquastat

13.Steam boilers under 200 horsepower must have low water cutoff tested how
often? - ANSWER ✓ When in operation and on low fire

14.What is an indication of a gauge glass not working properly? - ANSWER ✓
No movement in the water glass

15.When comparing a hot water boiler to a steam boiler, what does a hot water
boiler have that a steam boiler does not? - ANSWER ✓ Circulating pump,
expansion tank, and an aquastat

16.What is the device that will shut the boiler down in case of low water? -
ANSWER ✓ Low water cutoff

17.What must be displayed in a boiler room? - ANSWER ✓ Current license and
log book

18.According to national board code, safety valves are to be tested how often? -
ANSWER ✓ 90 days

19.What device removes air and condensate? - ANSWER ✓ Steam trap

20.What must be done after a hot water boiler has been drained, cleaned and
refilled? - ANSWER ✓ Remove air

21.What can a special engineer operate? - ANSWER ✓ In charge of 50
horsepower. Shift operator 100 horsepower high or low pressure

,22.What are the three main types of boilers? - ANSWER ✓ Fire tube, water
tube, cast iron sectional

23.How much experience is required for a special license? - ANSWER ✓ No
experience

24.At a minimum, what is required in a log book? - ANSWER ✓ Who, what
and when

25.When in operation a 40 horsepower boiler may be left unattended for how
long? - ANSWER ✓ 24 hours

26.What method of testing low water cut off most accurately simulates low
water? - ANSWER ✓ Shutting off the feed pump and feeder valve supply
and blowing down low water cutoff

27.How do we know if we are using and approved safety valve for a steam
boiler or a safety relief valve for a hot water boiler? - ANSWER ✓ A spring
loaded direct acting safety valve or safety relief valve.

28.Before testing a low water fuel cut-out what must be done? - ANSWER ✓
The burner must be on.

29.Heat can be transferred in how many ways? - ANSWER ✓ Three.

30.Aqua stats work by sensing: - ANSWER ✓ Temperature.

31.Name the different ways heat can be transferred and give a definition of each
way. - ANSWER ✓ Radiation, Conduction, Convection

32.How many types of boilers are there? - ANSWER ✓ Three: Fire tube, Water
tube, Cast iron sectional

33.What type of boiler can be made larger? - ANSWER ✓ Cast Iron sectional

34.What type of boiler has the water surrounding the tubes? - ANSWER ✓ Fire
tube

, 35.What type of boiler has the water running through the tubes? - ANSWER ✓
Water tube

36.Boiler room log books area state of Minnesota requirement for ever boiler
room, what are some of the things you should be writing down in the book?
- ANSWER ✓ The log entry should start out with today's date NEXT what
you did you do in the boiler room NEXT sign your name

37.What is condensate? - ANSWER ✓ Condensed steam

38.A firing cycle consists of events that safely controls the burning of a fuel.
What even occur first? - ANSWER ✓ Safety controls must be in the circuit.

39.After blowing down the water column and gauge glass you are looking for
the: - ANSWER ✓ Water reentering the gauge glass to rise promptly.

40.Give an example of cold water start for a hot water boiler. - ANSWER ✓
XXX

41.Two low water fuel cut-outs are required when the BTU input of the burner
exceeds: - ANSWER ✓ 750,000

42.A boiler equipped with the two low water fuel cut-outs must have
_______________ on the secondary low water fuel cut-out. - ANSWER ✓
A manual reset.

43.A boiler with a new burner OR a new boiler room must have: - ANSWER ✓
A kill switch by each door leaving the boiler room.

44.The low water fuel cut off should be tested: - ANSWER ✓ At least once a
day when the boiler is in operation.

45.What is the purpose of a check valve used in a feed water line going to a
steam boiler? - ANSWER ✓ To restrict the flow in one direction only.

46.Where would you expect to locate pyrometer? - ANSWER ✓ In the exhaust
gases leaving the boiler

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfBenjamin Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
450
Member since
1 year
Number of followers
14
Documents
3108
Last sold
1 hour ago
EXCELLENT ACHIEVERS LIBRARY

As a professional tutor, I provide exceptional assistance with homework, quizzes, and exams across various subjects, including Psychology, Nursing, Biological Sciences, Business, Engineering, Human Resource Management, and Mathematics. I am dedicated to offering high-quality support and ensuring that all work meets scholarly standards. To enhance the effectiveness of our services, I work with a team of experienced tutors to create comprehensive and effective revision materials. Together, we are committed to helping students achieve excellent grades through our collaborative efforts and expertise.

Read more Read less
3.8

83 reviews

5
37
4
12
3
24
2
4
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions