100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

INSTRUMENTAL ANALYSIS ACS EXAMINATION SCRIPT 2025/2026 QUESTIONS AND ANSWERS GUARANTEE A+

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
13-03-2025
Written in
2024/2025

how to find the detection limit for method? - 3.3*SD(blank)/calibration sensitivity voltage in a series - Vt = Vc + Vb + Va Voltage in a parallel circuit - 1/Veff = 1/Va + 1/Vb Capacitance in a series - 1/Ceff = 1/Ca + 1/Cb capacitance equals - Q/V if a spectrum is the result of a single scan while another is the result of multiple scans, how man individual spectra were summed to increase S/N from 4.2 to 43? a) formula? b) answer - a) (S/N)a = sqrt(n) (S/N)b b) 105 what type of noise can be reduced by decreasing the temperature of a measurement - thermal noise

Show more Read less
Institution
INSTRUMENTAL ANALYSIS
Course
INSTRUMENTAL ANALYSIS










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
INSTRUMENTAL ANALYSIS
Course
INSTRUMENTAL ANALYSIS

Document information

Uploaded on
March 13, 2025
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

INSTRUMENTAL ANALYSIS ACS EXAMINATION SCRIPT 2025/2026
QUESTIONS AND ANSWERS GUARANTEE A+
✔✔how to find the detection limit for method? - ✔✔3.3*SD(blank)/calibration sensitivity

✔✔voltage in a series - ✔✔Vt = Vc + Vb + Va

✔✔Voltage in a parallel circuit - ✔✔1/Veff = 1/Va + 1/Vb

✔✔Capacitance in a series - ✔✔1/Ceff = 1/Ca + 1/Cb

✔✔capacitance equals - ✔✔Q/V

✔✔if a spectrum is the result of a single scan while another is the result of multiple
scans, how man individual spectra were summed to increase S/N from 4.2 to 43?
a) formula?
b) answer - ✔✔a) (S/N)a = sqrt(n) (S/N)b
b) 105

✔✔what type of noise can be reduced by decreasing the temperature of a
measurement - ✔✔thermal noise

✔✔what type of noise can be reduced by decreasing the frequency used for the
measurement - ✔✔flicker noise

✔✔what type of noise can be reduced by decreasing the bandwidth of the
measurement - ✔✔environmental noise

✔✔What would be an appropriate source and detector to determine the emission lines
for lithium from 200 to 780 nm? - ✔✔flame and photo multiplier tube (PMT)

✔✔you've been asked to measure the UV absorbance of a sample containing poly
cyclic aromatic hydrocarbons, a byproduct of the incomplete combustion of organic
matter. What would be an appropriate material for the sample container? - ✔✔fused
silica or quartz

✔✔which of the following changes will result in a decreased effective bandwidth?
a) increasing the number of blazes in the monochromatic grating
b) switching from a short-pass filter to a long-pass filter
c) increasing sample concentration
d) decreasing the amount of stray light - ✔✔a

,✔✔what would be the distance between blazes for a grating where the first order
diffraction line for 600 nm light is reflected at 10 degrees and the angle of incidence light
is 45 degrees?
a) formula
b) answer - ✔✔a) n(wavelength) = distance*(sin(i)+sin(r))
b) 680 nm

✔✔which of the following would be considered a discontinuous wavelength selector?
a) quartz prism
b) Czerny-Turner Grating (monochormator)
c)interference filter
d)glass prism - ✔✔c

✔✔which characteristics are desirable for a radiation transducer?
a) high sensitivity to short wavelength light
b) low S/N ratio
c) consistent high output when not illuminated
d) constant response over large wavelength range
e) all of the above - ✔✔d

✔✔what is the appropriate process for atomization for AAS and AES? (3 steps) -
✔✔desolvation, vaporization, atomization

✔✔the doppler effect is one reason for line broadening in atomic spectroscopy. What is
the effect on a measured signal? - ✔✔movement of excited atoms toward the detector
causes a shortening in the wavelength of the emitted light

✔✔it is better to select an excitation source for AAS with ____bandwidth - ✔✔smaller

✔✔what is the general layout for AES? - ✔✔sample --> source --> wavelength selector -
-> detector

✔✔a)name the electrical signals that are considered analog?
b) how is the information encoded in an analog signal? - ✔✔a) current, voltage, charge,
and power
b) an analog signal is a signal where the amplitude of the signal changes with time, so
the information is encoded either through the amplitude or frequency of the signal (and
the signal can be wavelength, magnetic field strength, T,etc)

✔✔what is a figure of merit? - ✔✔it is a numerical value characterizing the quantitative
instrument performance and include precision, bias, sensitivity, detection limit, dynamic
range and selectivity

, ✔✔How long would it take to discharge a 0.015 microF capacitor to 1% of its full charge
through a resistance of 10 mega Ohms?
a) formula
b) answer - ✔✔a) vc= Vc e^(-t/RC)
b) t = 0.69 seconds

✔✔select the type of ionization technique used in MS that would result in significant
fragmentation
a) MALDI
b) electron impact
c) high performance
d) chemical ionization - ✔✔c

✔✔which is true for chemical ionization?
a) considered a "hard ionization" technique
b) analyte reacts with electron beam
c) compared to other ionization techniques, less fragmentation occurs
d)compared to other ionization techniques, results in the most repeatable small
fragments - ✔✔c

✔✔true or false
formation of ions in electrospray occurs by spraying the sample through a capillary,
where it is exposed to a high voltage source, then charged sample undergoes
desolvation. Once the Rayleigh limit is achieved, coulombic repulsions overcome any
surface tension of the liquid resulting in small, multiply charged species - ✔✔true

✔✔which of the following detectors would be appropriate for measuring the Raman
Spectra for samples irradiated with 455 nm light?
a)thermocouple
b)bolometer
c)photographic plate
d)charge-coupled device array (CCD) - ✔✔D

✔✔which of the following detectors would be appropriate for measuring the IR spectra?
a) CCD array
b) photographic plate
c) photomultiplier tube
d) pyroelectric detector - ✔✔d

✔✔which of the following sources would be appropriate excitation source for collecting
IR spectra?
a) hollow cathode tube
b) nernst glower
c) Xenon lamp

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
176
Member since
1 year
Number of followers
6
Documents
22568
Last sold
3 days ago
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3.6

32 reviews

5
13
4
6
3
7
2
0
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions