100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ASNT RT I Exam Questions And Answers 2025 Update

Rating
-
Sold
-
Pages
8
Grade
A+
Uploaded on
09-03-2025
Written in
2024/2025

©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM. 1 ASNT RT I Exam Questions And Answers 2025 Update. Although there may be other reasons for using calcium tungstate screens in industrial radiography, they are most usually used to: - AnswerDecrease exposure time In film radiography, pentrameters are usually placed: - Answeron the source side of the test object The penetrating ability of an x-ray beam is governed by: - AnswerKilovoltage Co-60 used in nondestructive testing emits: - AnswerGamma rays A densitometer is an instrument for measuring: - Answerfilm density Three liquids which are essential to process an exposed film properly are: - AnswerDeveloper, fixer and water The two most common causes for excessively high-density radiographs are: - Answeroverexposure and underdevelopment the time required for one-half of the atoms in a particular sample of radioactive material to disintegrate is called: - Answera half- life What does the term R/h refer to when speaking of intensity? - AnswerRoentgens per hour The ability to detect a small discontinuity or flaw is called: - Answerradiographic sensitivity Movement, geometry, and screen contact are three factors that affect radiographic: - Answerunsharpness The difference between the densities of two areas of a radiograph is called: - Answerradiographic contrast The most widely used unit of measurement for measuring the rate at which the output of a gamma ray source decays is the: - Answercurie ©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM. 2 Exposure to x-rays or gamma rays will have what effect on the body? - AnswerIt may have a cumulative effect which must be considered Which dose would be dangerous, if not fatal, if applied to the entire body in a short period of time? A. 1.5 - 15R B. 25 - 70R C. 200 - 800R D. All of the above doses would most likely be fatal - AnswerC. 200 - 800 R When doing gamma ray radiography with high- intensity emitters, the sources are best handled: - Answerby remote handling equipment If a film is placed in a developer solution and allowed to develop without any agitation: - AnswerThere will be a tendency for areas to affect each other The selection of the proper type of film to be used for the x-ray examination of a particular part depends on: - Answerthe thickness of the part, the material of the specimen, the voltage range of the available x-ray machine A Co-60 source has a half life of: - Answer5.3 Years x-ray tube current is controlled by: - Answerthe current passing through the filament The voltage and waveform applied to the x-ray tube by a high- voltage transformer primarily determines the: - Answerpenetrating ability lead foil in direct contact with x-ray film: - AnswerIntensifies the primary radiation more than the scatter radiation Fluorescent intensifying screens are usually mounted in pairs in rigid holders called: - AnswerCassettes Radiographic sensitivity, in the context of the minimum detectable flaw size, depends on: - Answergraininess of the film, the unsharpness of the flaw image in the film and the contrast the flaw image on the film In order to decrease geometric unsharpness: - AnswerRadiation should proceed from as small a focal spot as other considerations will allow As the Kilovoltage applied to the x-ray tube is raised: - Answerx-rays of shorter wavelength and more penetrating pow

Show more Read less
Institution
ASNT RT I
Course
ASNT RT I









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ASNT RT I
Course
ASNT RT I

Document information

Uploaded on
March 9, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM.




ASNT RT I Exam Questions And Answers
2025 Update.


Although there may be other reasons for using calcium tungstate screens in industrial
radiography, they are most usually used to: - Answer✔Decrease exposure time

In film radiography, pentrameters are usually placed: - Answer✔on the source side of the test
object

The penetrating ability of an x-ray beam is governed by: - Answer✔Kilovoltage

Co-60 used in nondestructive testing emits: - Answer✔Gamma rays

A densitometer is an instrument for measuring: - Answer✔film density

Three liquids which are essential to process an exposed film properly are: - Answer✔Developer,
fixer and water
The two most common causes for excessively high-density radiographs are: -
Answer✔overexposure and underdevelopment
the time required for one-half of the atoms in a particular sample of radioactive material to
disintegrate is called: - Answer✔a half- life

What does the term R/h refer to when speaking of intensity? - Answer✔Roentgens per hour

The ability to detect a small discontinuity or flaw is called: - Answer✔radiographic sensitivity
Movement, geometry, and screen contact are three factors that affect radiographic: -
Answer✔unsharpness
The difference between the densities of two areas of a radiograph is called: -
Answer✔radiographic contrast
The most widely used unit of measurement for measuring the rate at which the output of a
gamma ray source decays is the: - Answer✔curie



1

, ©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 8:10PM.


Exposure to x-rays or gamma rays will have what effect on the body? - Answer✔It may have a
cumulative effect which must be considered
Which dose would be dangerous, if not fatal, if applied to the entire body in a short period of
time?
A. 1.5 - 15R
B. 25 - 70R
C. 200 - 800R

D. All of the above doses would most likely be fatal - Answer✔C. 200 - 800 R
When doing gamma ray radiography with high- intensity emitters, the sources are best
handled: - Answer✔by remote handling equipment
If a film is placed in a developer solution and allowed to develop without any agitation: -
Answer✔There will be a tendency for areas to affect each other
The selection of the proper type of film to be used for the x-ray examination of a particular part
depends on: - Answer✔the thickness of the part, the material of the specimen, the voltage
range of the available x-ray machine

A Co-60 source has a half life of: - Answer✔5.3 Years

x-ray tube current is controlled by: - Answer✔the current passing through the filament
The voltage and waveform applied to the x-ray tube by a high- voltage transformer primarily
determines the: - Answer✔penetrating ability

lead foil in direct contact with x-ray film: - Answer✔Intensifies the primary radiation more than
the scatter radiation
Fluorescent intensifying screens are usually mounted in pairs in rigid holders called: -
Answer✔Cassettes
Radiographic sensitivity, in the context of the minimum detectable flaw size, depends on: -
Answer✔graininess of the film, the unsharpness of the flaw image in the film and the contrast
the flaw image on the film

In order to decrease geometric unsharpness: - Answer✔Radiation should proceed from as small
a focal spot as other considerations will allow

As the Kilovoltage applied to the x-ray tube is raised: - Answer✔x-rays of shorter wavelength
and more penetrating power are produced



2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay Kaplan University
View profile
Follow You need to be logged in order to follow users or courses
Sold
356
Member since
1 year
Number of followers
80
Documents
18669
Last sold
2 days ago
Scholar\'s Sanctuary.

Explore a Vast Collection of Finely Made Learning Materials.

3.7

68 reviews

5
32
4
8
3
13
2
6
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions