AMT Airframe Written Test (FAA) Exam Questions and Answers 100% Pass 5 (9001) - Smoke detection instruments are classified by their method of - C- detection. 1 (8997) - In what area of an aircraft would you find a carbon monoxide detector? - B- Cockpit and/or cabin. 2 (8998) - What occurs when a visual smoke detector is activated? - B- A lamp within the indicator illuminates automatically 3 (8999) - The types of fire-extinguishing agents for aircraft interior fires are - A- water, carbon dioxide, dry chemical, and halogenated hydrocarbons 4 (9000) - When air samples contain carbon monoxide, portable carbon monoxide detectors containing yellow silica gel will turn which color? - B- Green. 6 (9002) - Smoke detectors which use a measurement of light transmissibility in the air are called - B- photoelectrical devices. 2100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 7 (9003) - A contaminated carbon monoxide portable test unit would be returned to service by - B- installing a new indicating element. 8 (9004) - Which fire-detection system measures temperature rise compared to a reference temperature? - C- Thermocouple. 9 (9005) - A carbon dioxide (CO(2)) hand-held fire extinguisher may be used on an electrical fire if the - A- horn is nonmetallic. 10 (9006) - The proper fire-extinguishing agent to use on an aircraft brake fire is - C- dry powder chemical. 11 (9007) - Smoke in the cargo and/or baggage compartment of an aircraft is commonly detected by which instrument? - B- Photoelectric cell. 12 (9008) - Light refraction smoke detectors are activated when the detector - B- senses light reflected from smoke particles passing through a chamber 13 (9009) - Why does the Fenwal fire-detection system use spot detectors wired parallel between two separate circuits? - C- A short may exist in either circuit without causing a false fire warning. 14 (9010) - A fire-extinguisher container can be checked to determine its charge by - B- weighing the container and its contents. 15 (9011) - What is the color code for fire-extinguisher lines? - A- Brown. 3100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 16 (9012) - The most common cause of false fire warnings in continuous-loop fire- detection systems is - C- dents, kinks, or crushed sensor sections. 17 (9013) - A thermocouple in a fire-detection system causes the warning system to operate because - A- it generates a small current when heated. 18 (9014) - The thermocouple fire-warning system is activated by a - C- rate-of- temperature rise. 19 (9015) - When used in fire-detection systems having a single indicator light, thermal switches are wired in - A- parallel with each other and in series with the light. 20 (9016) - Built-in aircraft fire-extinguishing systems are ordinarily charged with - B- halogenated hydrocarbons and nitrogen 21 (9017) - In reference to aircraft fire-extinguishing systems,(1) during removal or installation, the terminals of discharge cartridges should be grounded or shorted.(2) before connecting cartridge terminals to the electrical system, the syst

Show more Read less
Institution
FAA
Course
FAA











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FAA
Course
FAA

Document information

Uploaded on
March 9, 2025
Number of pages
141
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

AMT Airframe Written Test (FAA)
Exam Questions and Answers 100%
Pass


5 (9001) - Smoke detection instruments are classified by their method of - ✔✔C-

detection.


1 (8997) - In what area of an aircraft would you find a carbon monoxide detector? -

✔✔B- Cockpit and/or cabin.


2 (8998) - What occurs when a visual smoke detector is activated? - ✔✔B- A lamp within

the indicator illuminates automatically


3 (8999) - The types of fire-extinguishing agents for aircraft interior fires are - ✔✔A-

water, carbon dioxide, dry chemical, and halogenated hydrocarbons


4 (9000) - When air samples contain carbon monoxide, portable carbon monoxide

detectors containing yellow silica gel will turn which color? - ✔✔B- Green.


6 (9002) - Smoke detectors which use a measurement of light transmissibility in the air

are called - ✔✔B- photoelectrical devices.


100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 1

,7 (9003) - A contaminated carbon monoxide portable test unit would be returned to

service by - ✔✔B- installing a new indicating element.


8 (9004) - Which fire-detection system measures temperature rise compared to a

reference temperature? - ✔✔C- Thermocouple.


9 (9005) - A carbon dioxide (CO(2)) hand-held fire extinguisher may be used on an

electrical fire if the - ✔✔A- horn is nonmetallic.


10 (9006) - The proper fire-extinguishing agent to use on an aircraft brake fire is - ✔✔C-

dry powder chemical.


11 (9007) - Smoke in the cargo and/or baggage compartment of an aircraft is commonly

detected by which instrument? - ✔✔B- Photoelectric cell.


12 (9008) - Light refraction smoke detectors are activated when the detector - ✔✔B-

senses light reflected from smoke particles passing through a chamber


13 (9009) - Why does the Fenwal fire-detection system use spot detectors wired parallel

between two separate circuits? - ✔✔C- A short may exist in either circuit without

causing a false fire warning.


14 (9010) - A fire-extinguisher container can be checked to determine its charge by -

✔✔B- weighing the container and its contents.


15 (9011) - What is the color code for fire-extinguisher lines? - ✔✔A- Brown.




100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 2

,16 (9012) - The most common cause of false fire warnings in continuous-loop fire-

detection systems is - ✔✔C- dents, kinks, or crushed sensor sections.


17 (9013) - A thermocouple in a fire-detection system causes the warning system to

operate because - ✔✔A- it generates a small current when heated.


18 (9014) - The thermocouple fire-warning system is activated by a - ✔✔C- rate-of-

temperature rise.


19 (9015) - When used in fire-detection systems having a single indicator light, thermal

switches are wired in - ✔✔A- parallel with each other and in series with the light.


20 (9016) - Built-in aircraft fire-extinguishing systems are ordinarily charged with -

✔✔B- halogenated hydrocarbons and nitrogen


21 (9017) - In reference to aircraft fire-extinguishing systems,(1) during removal or

installation, the terminals of discharge cartridges should be grounded or shorted.(2)

before connecting cartridge terminals to the electrical system, the system should be

checked with a voltmeter to see that no voltage exists at the terminal

connections.Regarding the above statements, - ✔✔B- both No. 1 and No. 2 are true.


22 (9018) - What method is used to detect the thermal discharge of a built-in fire-

extinguisher system? - ✔✔B- A rupture of the red plastic disk in the thermal discharge

line.




100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 3

, 23 (9019) - The thermal switches of a bimetallic thermal-switch type fire-detection

(single-loop) system are heat-sensitive units that complete circuits at a certain

temperature. They are connected in - ✔✔B- parallel with each other, but in series with

the indicator lights.


24 (9020) - (Refer to Figure 21.) Using the chart, determine the temperature range for a

fire-extinguishing agent storage container with a pressure of 330 PSIG. (Consider 330

PSIG for both minimum and maximum pressure.) - ✔✔C- 45 to 73°F.


25 (9021) - (Refer to Figure 21.) Determine what pressure is acceptable for a fire

extinguisher when the surrounding area temperature is 33°F. (Rounded to the nearest

whole number.) - ✔✔A- 215 to 302 PSIG.


26 (9022) - On a periodic check of fire-extinguisher containers, the pressure was not

between minimum and maximum limits. What procedure should be followed? - ✔✔B-

Replace the extinguisher container.


27 (9023) - In some fire-extinguishing systems, evidence that the system has been

intentionally discharged is indicated by the absence of a - ✔✔C- yellow disk on the side

of the fuselage.


28 (9024) - If a fire extinguisher cartridge is removed from a discharge valve, it should

be - ✔✔B- used only on the original discharge valve assembly.




100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 4

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1088
Member since
2 year
Number of followers
482
Documents
33020
Last sold
1 day ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

236 reviews

5
95
4
38
3
54
2
20
1
29

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions