Exam Questions and Answers 100%
Pass
5 (9001) - Smoke detection instruments are classified by their method of - ✔✔C-
detection.
1 (8997) - In what area of an aircraft would you find a carbon monoxide detector? -
✔✔B- Cockpit and/or cabin.
2 (8998) - What occurs when a visual smoke detector is activated? - ✔✔B- A lamp within
the indicator illuminates automatically
3 (8999) - The types of fire-extinguishing agents for aircraft interior fires are - ✔✔A-
water, carbon dioxide, dry chemical, and halogenated hydrocarbons
4 (9000) - When air samples contain carbon monoxide, portable carbon monoxide
detectors containing yellow silica gel will turn which color? - ✔✔B- Green.
6 (9002) - Smoke detectors which use a measurement of light transmissibility in the air
are called - ✔✔B- photoelectrical devices.
100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 1
,7 (9003) - A contaminated carbon monoxide portable test unit would be returned to
service by - ✔✔B- installing a new indicating element.
8 (9004) - Which fire-detection system measures temperature rise compared to a
reference temperature? - ✔✔C- Thermocouple.
9 (9005) - A carbon dioxide (CO(2)) hand-held fire extinguisher may be used on an
electrical fire if the - ✔✔A- horn is nonmetallic.
10 (9006) - The proper fire-extinguishing agent to use on an aircraft brake fire is - ✔✔C-
dry powder chemical.
11 (9007) - Smoke in the cargo and/or baggage compartment of an aircraft is commonly
detected by which instrument? - ✔✔B- Photoelectric cell.
12 (9008) - Light refraction smoke detectors are activated when the detector - ✔✔B-
senses light reflected from smoke particles passing through a chamber
13 (9009) - Why does the Fenwal fire-detection system use spot detectors wired parallel
between two separate circuits? - ✔✔C- A short may exist in either circuit without
causing a false fire warning.
14 (9010) - A fire-extinguisher container can be checked to determine its charge by -
✔✔B- weighing the container and its contents.
15 (9011) - What is the color code for fire-extinguisher lines? - ✔✔A- Brown.
100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 2
,16 (9012) - The most common cause of false fire warnings in continuous-loop fire-
detection systems is - ✔✔C- dents, kinks, or crushed sensor sections.
17 (9013) - A thermocouple in a fire-detection system causes the warning system to
operate because - ✔✔A- it generates a small current when heated.
18 (9014) - The thermocouple fire-warning system is activated by a - ✔✔C- rate-of-
temperature rise.
19 (9015) - When used in fire-detection systems having a single indicator light, thermal
switches are wired in - ✔✔A- parallel with each other and in series with the light.
20 (9016) - Built-in aircraft fire-extinguishing systems are ordinarily charged with -
✔✔B- halogenated hydrocarbons and nitrogen
21 (9017) - In reference to aircraft fire-extinguishing systems,(1) during removal or
installation, the terminals of discharge cartridges should be grounded or shorted.(2)
before connecting cartridge terminals to the electrical system, the system should be
checked with a voltmeter to see that no voltage exists at the terminal
connections.Regarding the above statements, - ✔✔B- both No. 1 and No. 2 are true.
22 (9018) - What method is used to detect the thermal discharge of a built-in fire-
extinguisher system? - ✔✔B- A rupture of the red plastic disk in the thermal discharge
line.
100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 3
, 23 (9019) - The thermal switches of a bimetallic thermal-switch type fire-detection
(single-loop) system are heat-sensitive units that complete circuits at a certain
temperature. They are connected in - ✔✔B- parallel with each other, but in series with
the indicator lights.
24 (9020) - (Refer to Figure 21.) Using the chart, determine the temperature range for a
fire-extinguishing agent storage container with a pressure of 330 PSIG. (Consider 330
PSIG for both minimum and maximum pressure.) - ✔✔C- 45 to 73°F.
25 (9021) - (Refer to Figure 21.) Determine what pressure is acceptable for a fire
extinguisher when the surrounding area temperature is 33°F. (Rounded to the nearest
whole number.) - ✔✔A- 215 to 302 PSIG.
26 (9022) - On a periodic check of fire-extinguisher containers, the pressure was not
between minimum and maximum limits. What procedure should be followed? - ✔✔B-
Replace the extinguisher container.
27 (9023) - In some fire-extinguishing systems, evidence that the system has been
intentionally discharged is indicated by the absence of a - ✔✔C- yellow disk on the side
of the fuselage.
28 (9024) - If a fire extinguisher cartridge is removed from a discharge valve, it should
be - ✔✔B- used only on the original discharge valve assembly.
100% Pass Guarantee Katelyn Whitman, All Rights Reserved © 2025 4