HVAC (GAS HEAT) MASTER TEST EXAM
QUESTIONS WITH CORRECT ANSWERS
The maximum allowable concentration of continuous 24hr exposure of Carbon
monoxide according to ASHRAE is about ___________ - Answer-0.009 ppm

When burning natural gas, the air adjustment is generally made to secure as
__________ a flame as possible - Answer-Blue

___________ on pipes and pipe fittings should be located by spreading a soap solution
over the surface - Answer-Gas Leaks

Which of the following gas is the main constituent in Natural gas - Answer-Methane

A yellow flame indicates dependence entirely on ______ air for combustion - Answer-
Secondary

The primary air is admitted at a ratio of about _______ parts primary air to 1 part gas for
natural gas - Answer-10

During incomplete combustion which of the following is produced - Answer-CO

Propane is ______ than air - Answer-Heavier

Natural gas has a specific gravity of _____ - Answer-0.6

Which fittings should NOT be used for the main gas line - Answer-Aluminum tubing

OSHA standards prohibit worker exposure to Carbon monoxide not more than _____
PPM air averaged during an 8 hour period - Answer-50

Install the main manual gas shutoff valve on the riser at least _______ above the floor
level - Answer-4 ft

The Bunsen burner flame is practically _________ - Answer-Nonluminous

The burner tube of an ________ is commonly a straight, adjustable venturi that extends
horizontally from the unit - Answer-Inshot Gas Burner

A ___________ is used to ensure the maintenance of constant lowdraft conditions in
the combustion chamber with a resultant stability of air supply - Answer-Draft Hood

LPG has a heating capacity of approximately _______ Btu per cubic foot - Answer-2500

, What is Required for proper combustion - Answer-Fuel, Ignition, Oxygen

Line Burners can produce over _____ BTU/Hr per foot of length - Answer-1,000,000

During complete combustion which of the following is produced - Answer-CO2, H2O,
O2

The percentage of carbon dioxide in the flue gases for natural gas should be about
______ - Answer-7 to 9%

Fuel heating value of Natural gas will be in the range of ______ Btu/ft^3 - Answer-900 -
1200

Install the pilot valve on the ______ side of the main manual gas shutoff valve - Answer-
Inlet

The _______ air is drawn into the burner by natural draft - Answer-Secondary

What are the primary constituents of Liquid Petroleum Gas (LPG) - Answer-Butane,
Propane

Most atmospheric injection burners operate efficiently on _______ of the theoretical
value - Answer-40 to 60%

soldered or sweated connections are also not recommended in ________ - Answer-Gas
piping, oil piping

Which of the following gas is lighter than air - Answer-Natural Gas

All electrical connection to heating appliances shall comply with - Answer-NEC

Which of the following gas is not a constituent of Natural gas - Answer-Acetane

A customer tells a technician that his six month old furnace stops heating before the
residence is warm. This happens only on very cold nights. The technician lights the
furnace, and tries to adjust the gas valve, but the flames do not change. He suspects: -
Answer-a defective gas valve regulator.

A technician connects the electrical circuit to an 80,000 BTU gas furnace with a 3-ton
cooling system. The fan motor is rated 1/3 HP @ 120 VAC. What size conductor would
normally be used? (copper conductors) - Answer-12-14 AWG

A customer complains that a 2-year-old gas furnace will not light. The technician
determines that the furnace locks out while attempting to light. He reads 19 VAC at the
input of the electroinc board and the gas valve. The technician concludes: - Answer-the
transformer could be faulty.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
biggdreamer Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
247
Member since
2 year
Number of followers
68
Documents
17956
Last sold
9 hours ago

4.0

38 reviews

5
22
4
4
3
6
2
2
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions