Which of the following statements are correct regarding the link
between radiation dose and genetic effects?
1. The link has been demonstrated in human studies.
2. The link has been demonstrated in animal studies.
3. increased risk to humans cannot be predicted with respect to an
individual. - ACCURATE ANSWERS✔✔ 2 and 3 only
Which of the following changes in kilovoltage (KVP) will result in the
greatest reduction of patient dose, when milliamperage-seconds (mAs) is
adjusted to compensate for the dosage?
A.) Decrease kVp by 30%
B.) Decrease kVp by 15%
C.) Increase kVp by 15%
D.) Increase kVp by 30% - ACCURATE ANSWERS✔✔ Increase kVp
by 30%
Which of the following image receptor (IR) system speeds will result in
the lowest patient dose?
A.) slower speed IR system
,B.) Faster speed IR system
C.) It does not matter; the IR system speed does not affect the patient
dose. - ACCURATE ANSWERS✔✔ Faster speed IR system
What is the primary purpose of using gonad shields during radiography?
A.) Reduce the likelihood of genetic changes
B.) Reduce likelihood of somatic effects
C.) Protect patient modesty
D.) Demonstrate the location of the gonads in the image - ACCURATE
ANSWERS✔✔ Reduce the likelihood of genetic changes
Which one of the following are types of gonad shields?
1. Aperture
2. Contact
3. Shadow
A.) 1 and 2 only
B.) 1 and 3 only
C.) 2 and 3 only
D.) 1, 2, and 3 - ACCURATE ANSWERS✔✔ 2 and 3 only
When should gonad shielding be used?
A.) for all patients
B.) For all procedures
,C.) when the gonads are within 10 cm of the radiation field
D.) when the gonads are within 5 cm of the radiation field -
ACCURATE ANSWERS✔✔ when the gonads are within 5 cm of the
radiation field
The greatest cause of unnecessary radiation to patients that can be
controlled by the limited operator is:
A.) Patient condition
B.) Patient size
C.) Repeat exposure
D.) equipment malfunction - ACCURATE ANSWERS✔✔ Repeat
exposure
The limited operator can reduce repeat exposures by:
A.) Accepting marginal images
B.) Clearly instructing patients
C.) increasing the source-image receptor distance (SID)
D.) optimizing the kVp - ACCURATE ANSWERS✔✔ Clearly
instructing patients
How does x-ray beam restriction minimize patient exposure?
A.) it limits radiation fog
B.) It limits the radiation field to the area of interest
, C.) It limits the effect of patient motion
D.) It limits repeat exposure - ACCURATE ANSWERS✔✔ It limits the
radiation field to the area of interest
What is the device that allows the limited operator to vary the size of the
radiation field?
A.) Collimator
B.) Detent
C.) Filter
D.) Sheild - ACCURATE ANSWERS✔✔ Collimator
How does filtration reduce patient exposure?
A.) Removes the shorter-wavelength photons
B.) Removes longer wavelength photons
C.) Reduces the size of the radiation field
D.) Reduces the time of exposure - ACCURATE ANSWERS✔✔
Removes longer wavelength photons
What is the National Council on Radiation Protection and Measurements
(NCRP) recommendation for the amount of total filtration?
A.) 0.5mm aluminum equivalent ( AL Equiv)
B.) 1.5mm AL Equiv
C.) 2.5mm Al Equiv