100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NEC 2017 JOURNEYMAN STUDY GUIDE EXAM QUESTION WITH ANSWERS 2025/2026 GRADED A+

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
23-02-2025
Written in
2024/2025

NEC 2017 JOURNEYMAN STUDY GUIDE EXAM QUESTION WITH ANSWERS 2025/2026 GRADED A+ Service drop conductors shall maintain _____ clearance from the sides and bottoms of operable windows. - 3', 225.19(D)(1),230.9(A) Overhead service drop conductors shall not be smaller than _____ away copper wire. - 8, 230.23(B) According to the NEC, service drop conductors (600v or less) must be _____ above finish grade. - 10',230.24(B)(1) What is the overhead clearance for service conductors 600 volts and less going over a residential property? - 12', 230.24(B)(2) Service entrance cables shall be supported by approached means within ____ ft of every service head and at intervals not exceeding _____ ft. - 12", 30", 230.51(A) Cable limiters are not permitted to be connected to the supply side of the service disconnecting means. T/F - False, 230.82(1) What is the maximum size fuse that can be installed for a #18 fixture wire and be considered protected? - 20, 240.5(B)(2)

Show more Read less
Institution
NEC
Course
NEC









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NEC
Course
NEC

Document information

Uploaded on
February 23, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NEC 2017 JOURNEYMAN STUDY GUIDE EXAM QUESTION
WITH ANSWERS 2025/2026 GRADED A+
Service drop conductors shall maintain _____ clearance from the sides and bottoms of
operable windows. - 3', 225.19(D)(1),230.9(A)

Overhead service drop conductors shall not be smaller than _____ away copper wire. -
8, 230.23(B)

According to the NEC, service drop conductors (600v or less) must be _____ above
finish grade. - 10',230.24(B)(1)

What is the overhead clearance for service conductors 600 volts and less going over a
residential property? - 12', 230.24(B)(2)

Service entrance cables shall be supported by approached means within ____ ft of
every service head and at intervals not exceeding _____ ft. - 12", 30", 230.51(A)

Cable limiters are not permitted to be connected to the supply side of the service
disconnecting means. T/F - False, 230.82(1)

What is the maximum size fuse that can be installed for a #18 fixture wire and be
considered protected? - 20, 240.5(B)(2)

Type S adapters shall be designed so that once inserted in a fuse holder, they ____. -
Cannot be removed, 240.54(C)

What is the minimum spacing between grounding electrodes? - 6', 250.53(B)

In a building where a metal underground water line is available, the maximum size of
the grounding electrode conductor for an ungrounded system with 3/0 copper service
conductors shall be? - #4 AWG copper, 250.66

Interior metal water piping located not more than ____ from the point of entrance to a
building shall be permitted to be used as a conductor to interconnect electrodes that are
part of the grounding system. - 5', 250.68(C)

What is the minimum size grounded conductor permitted to be installed when the
ungrounded conductors are size 1/0 copper? - #6 AWG copper, Table 250.102(C)(1)

A conductor intended solely for the purposes of grounding shall be either bare or color
coded ______ or _______. - Green, Green with a yellow stripe, 250.119

Where metal fences are located within ____ft of the electrical conductors or equipment,
the fence shall be bonded. - 16', 250.194(A)

, Underground service conductors not encased in concrete shall be identified by a
warning ribbon _____ inches above the underground installation. - 12", 300.4(D)(3)

Where raceways contain ____ AWG or larger insulated conductors that enter a box the
conductors shall be protected by a bushing. - 4AWG, 300.4(G)

Residential direct burial branch circuits rated 120V or less with GFCI protection and a
maximum over current protection of 20A shall have a minimum cover requirement of __
inches. - 12, Table 300.5

Direct buried service conductors, 1000V and less, shall have a minimum cover of ___
inches of dirt. - 24", Table 300.5

The free length of conductors at each outlet and switch point for connecting to devices
is ___ inches. - 6", 300.14

Four #10 THHN, copper, current carrying conductors are installed in the same EMT in a
e being temperature of 30*C. the allowable ampacity of each of the conductors is ___
amps. - 32, Table 310.15(B)(3)(a), Table 310.15(B)(16)

For a 150a dwelling unit service what is the demand factor? - 83% 310.15(B)(7)

The capacity of a #10 TW not more than 3 wires when installed on a conduit or cable is
___ amps. - 30, Table 310.15(B)(16)

What is the amperage rating of a #2 FEPB cable? - 293A, 310.15(B)(19)

What is the wire size range for type XHH cable with 45 mil insulation? - 8-2AWG, Table
310.104(A)

Conductors ____ and larger must be stranded. - 8AWG, 310.106(C)

Size approved drainage openings shall be permitted to be installed in conduit bodies
used in wet locations. - Not larger than 1/4", 314.15

What trade size round/octagonal box has a minimum of 21.5in^2? - 4 x 2 1/8" round ,
octagonal, Table 314.16(A)

What is the minimum volume of a box trade size (4x 2 1/8 x 1 1/2) - 10.3"^3, Table
314.16(A)

What is the volume allowance for #18AWG conductor? - 1.5 in^3, Table 314.16(B)

When determining the numbers of wires in a box for box fill, a conductor passing
through the box without a splice or tap with a conductor loop less than 12" is counted as
___. - One volume allowance, 314.16(B)(1)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
181
Member since
1 year
Number of followers
6
Documents
24136
Last sold
16 hours ago
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3.7

33 reviews

5
14
4
6
3
7
2
0
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions