CRCST PRACTICE TEST QUESTIONS AND ANSWERS 100% PASS Question - Answer What states that All patient information is highly confidential and should NEVER be discussed with anyone at any time unless it is required for the direct care of the patient? - HIPPA This process is defined by AAMI as the removal of contamination from an item to the extent necessary for further processing or for the intended use. - cleaning What type of stainless steel is used to manufacture scissors, forceps, osteotomes, and chisels? - 400 series What type of material is used the most in the manufacturing of surgical instrumentation? - stainless steel What is the proper order of how work progresses through the CSPD? - Decontam, Prep and pack, sterilizer, sterile storage What is defined as microorganisms on a contaminated item? - Bioburden 2100% Pass Guarantee Olivia West, All Rights Reserved © 2025 What type of stainless steel is used to manufacture basins, bowls, and malleable retractors? - 300 series The two steps in the process of decontamination? - manual cleaning and thermal process As defined by OSHA what is defined as "the use of physical or chemical means to remove, inactivate or destroy blood borne pathogens on a surface or item to the point where they are no longer capable of transmitting infectious particles and the surface of - decontamination A Sales Rep brings in a new Stryker Drill for Dr Bridwell to try during a total hip procedure. What is the first step that should be taken? - Ask for written instructions. The temperature in the decontamination department: - 60°-65° F Sharps in the decontamination department should be confined and contained in what type of leak proof container? - impervious After thoroughly cleaning a contaminated item the most important step in the decontamination process is to _____________ the item. - rinsed Humidity level in a CS department should be kept at what percent? - 30-60% Instruments in the OR that are just opened but not used still have to go through the decontam process, only when? - every time and always considered contaminated 3100% Pass Guarantee Olivia West, All Rights Reserved © 2025 What is the groups or collections of microorganisms that adhere to the surface of any object that comes into contact with nonsterile water? - biofilms What when used in small amounts is extremely corrosive to surgical instruments, and it's use in the decontamination process is prohibited? - bleach A pH level of 7 is considered? - neutral Instruments should never be stored _________________, and all instruments should be sterilized as soon as possible after cleaning. - wet The air pressure in the decontamination department should be wha

Show more Read less
Institution
Sterilization Process
Course
Sterilization Process










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Sterilization Process
Course
Sterilization Process

Document information

Uploaded on
February 16, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

CRCST PRACTICE TEST QUESTIONS
AND ANSWERS 100% PASS


Question - ✔✔Answer


What states that All patient information is highly confidential and should NEVER be

discussed with anyone at any time unless it is required for the direct care of the patient?

- ✔✔HIPPA


This process is defined by AAMI as the removal of contamination from an item to the

extent necessary for further processing or for the intended use. - ✔✔cleaning


What type of stainless steel is used to manufacture scissors, forceps, osteotomes, and

chisels? - ✔✔400 series


What type of material is used the most in the manufacturing of surgical

instrumentation? - ✔✔stainless steel


What is the proper order of how work progresses through the CSPD? - ✔✔Decontam,

Prep and pack, sterilizer, sterile storage


What is defined as microorganisms on a contaminated item? - ✔✔Bioburden




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 1

,What type of stainless steel is used to manufacture basins, bowls, and malleable

retractors? - ✔✔300 series


The two steps in the process of decontamination? - ✔✔manual cleaning and thermal

process


As defined by OSHA what is defined as "the use of physical or chemical means to

remove, inactivate or destroy blood borne pathogens on a surface or item to the point

where they are no longer capable of transmitting infectious particles and the surface of -

✔✔decontamination


A Sales Rep brings in a new Stryker Drill for Dr Bridwell to try during a total hip

procedure. What is the first step that should be taken? - ✔✔Ask for written instructions.


The temperature in the decontamination department: - ✔✔60°-65° F


Sharps in the decontamination department should be confined and contained in what

type of leak proof container? - ✔✔impervious


After thoroughly cleaning a contaminated item the most important step in the

decontamination process is to _____________ the item. - ✔✔rinsed


Humidity level in a CS department should be kept at what percent? - ✔✔30-60%


Instruments in the OR that are just opened but not used still have to go through the

decontam process, only when? - ✔✔every time and always considered contaminated




100% Pass Guarantee Olivia West, All Rights Reserved © 2025 2

, What is the groups or collections of microorganisms that adhere to the surface of any

object that comes into contact with nonsterile water? - ✔✔biofilms


What when used in small amounts is extremely corrosive to surgical instruments, and

it's use in the decontamination process is prohibited? - ✔✔bleach


A pH level of 7 is considered? - ✔✔neutral


Instruments should never be stored _________________, and all instruments should be

sterilized as soon as possible after cleaning. - ✔✔wet


The air pressure in the decontamination department should be what? - ✔✔negative


How many air exchanges per hour is the decontamination department suppose to have?

- ✔✔10


How often is the temperature and humidity levels suppose to be documented? -

✔✔daily


What forms a protective slimy film on top of water and on instruments during the

decontamination process? - ✔✔biofilms


A pH level of below 7 is considered? - ✔✔acidic


Items that have been presoaked or treated must be ____________ thoroughly before

further cleaning, because the presoaking or treatment agent may not be compatible with

the detergents used for cleaning. - ✔✔rinsed



100% Pass Guarantee Olivia West, All Rights Reserved © 2025 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
OliviaWest Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
105
Member since
1 year
Number of followers
17
Documents
8528
Last sold
3 days ago
Pure Orchid Haven.

All Documents,and package deals offered by seller Olivia West.

2.8

22 reviews

5
6
4
2
3
4
2
1
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions