100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ASE A6 Test Prep (Electrical & Electronic Systems) Questions and Answers 100% Correct

Rating
-
Sold
-
Pages
75
Grade
A+
Uploaded on
13-02-2025
Written in
2024/2025

ASE A6 Test Prep (Electrical & Electronic Systems)

Institution
ASE
Course
ASE











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ASE
Course
ASE

Document information

Uploaded on
February 13, 2025
Number of pages
75
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ASE A6 Test Prep (Electrical &
Electronic Systems)

Technician A only - answerA technician connects one lead of a DMM (digital multimeter)
to the positive (+) terminal of a battery and the other meter lead to the "B" terminal of
the starter solenoid and then cranks the engine. During cranking, the voltmeter displays
a reading of 878 mV.

Technician A says this reading indicates the positive battery cable has very high
resistance.

Technician B says this reading indicates that the starter armature is defective.

Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Replace the battery - answerWhen performing a load test on a battery, a technician
finds that the battery voltage drops below specifications. Which of the following is the
MOST likely repair?

a. Recharge the battery and return it to service
b. Recharge the battery and retest it
c. Replace the battery
d. Replace the voltage regulator

Technician A only - answerTwo technicians are describing battery charging.

Technician A says to remove the surface charge from a recently charged battery and
apply a 300-ampere load across the adapters for 15 seconds.

Technician B says to remove the surface charge from batteries, which have been in
storage.

Who is right?

Technician A only
Technician B only

,Both Technicians A and B
Neither Technician A nor B

Technician A only - answerA technician connects one lead of a DMM (digital multimeter)
to the positive (+) terminal of a battery and the other meter lead to the "B" terminal of
the starter solenoid and then cranks the engine. During cranking, the voltmeter displays
a reading of 878 mV.

Technician A only - answerA technician connects one lead of a DMM (digital multimeter)
to the positive (+) terminal of a battery and the other meter lead to the "B" terminal of
the starter solenoid and then cranks the engine. During cranking, the voltmeter displays
a reading of 878 mV.

Technician A says this reading indicates the positive battery cable has very high
resistance.

Technician B says this reading indicates that the starter armature is defective.

Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Replace the battery - answerWhen performing a load test on a battery, a technician
finds that the battery voltage drops below specifications. Which of the following is the
MOST likely repair?

a. Recharge the battery and return it to service
b. Recharge the battery and retest it
c. Replace the battery
d. Replace the voltage regulator

Technician A only - answerTwo technicians are describing battery charging.

Technician A says to remove the surface charge from a recently charged battery and
apply a 300-ampere load across the adapters for 15 seconds.

Technician B says to remove the surface charge from batteries, which have been in
storage.

Who is right?

Technician A only
Technician B only

,Both Technicians A and B
Neither Technician A nor B

Technician A only - answerA technician connects one lead of a DMM (digital multimeter)
to the positive (+) terminal of a battery and the other meter lead to the "B" terminal of
the starter solenoid and then cranks the engine. During cranking, the voltmeter displays
a reading of 878 mV.

Technician A says this reading indicates the positive battery cable has very high
resistance.

Technician B says this reading indicates that the starter armature is defective.

Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Technician B only - answerTechnician A says proper starter operation depends on the
battery being at a 95% charge and battery cables being of the correct size (gauge) and
having no more than 0.8-volt drop.

Technician B says voltage-drop testing includes cranking the engine, measuring the
drop in voltage from the battery to the starter, and measuring the drop in voltage from
the negative terminal of the battery to the engine block.

Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Defective starter drive - answerWhich of the following could cause the starter to make a
whining noise when engaged?

a. Defective starter drive
b. Defective solenoid
c. Open pull-in winding
d. Worn armature commutator

Neither Technician A nor B - answerTwo bulbs are connected in parallel to a 12 volt
battery. Another bulb is added in parallel.

, Technician A says that the third bulb will be dimmer than the other two bulbs due to
reduced current flow through the filament of the bulb.
Technician B says that the amount of current flowing from the battery will decrease due
to the extra load.
Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Technician B only - answerTwo bulbs are connected in parallel to a 12 volt battery. One
bulb has a resistance of 6 ohms and the other has a resistance of 2 ohms.
Technician A says that only the 2 ohm bulb will light because all the current will flow
through the 6 ohms bulb.
Technician B says that the 6 ohm bulb will be dimmer than the 2 ohm bulb.
Who is right?

Technician A only
Technician B only
Both Technicians A and B
Neither Technician A nor B

Both B & C - answerWhat causes a fuse to blow ?

a. A sudden decrease in current through the circuit
b. An increase in current through the circuit
c. A decrease in circuit resistance
d. Both B & C

Both B & C - answerMany ground straps are uninsulated and braided because
__________ ?

a. They are less expensive than conventional wire
b. They are more flexible to allow movement of the engine without breaking the wire
c. They dampen Radio-Frequency Interference (RFI)
d. Both B & C

Both Technicians A and B - answerTechnician A says that a test light should light on
both test points of the fuse if it is ok.
Technician B says that the fuse is defective if a test light only lights on one side of the
fuse.
Who is right?

Technician A only
Technician B only

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Dreamer252 NBursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
478
Member since
2 year
Number of followers
293
Documents
21305
Last sold
2 days ago

4.0

115 reviews

5
60
4
22
3
18
2
2
1
13

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions