BIPC 620 Exam Questions And Answers|
Already Graded A+| Latest Update.
Certified IPC Trainter CIT and Certified IPC Specilist certifications exipre after how many years -
Answer✔2 Years
Master IPC Trainers MIT are authorized to ceritfy - Answer✔CIT and CIS only
A CIT is authorized to ceritfy - Answer✔CIS
If permitted by company policy, a CIT may grant an extension of up to how many days -
Answer✔90 days
What module is required as a pre req. for IPC 620 CIS certification - Answer✔Module 1
CIS retesting may be taken only after a minimum of - Answer✔24 hours
What is the correct order of production status - Answer✔Design, PCB Fabrication, Assemly,
Cleaning and Coating
The tolerance for magnification aid is - Answer✔Plus or Minus 15 (Chapter 1) Page 1-7
The Manufacturer shall (_1_2_3) have a documented calibration system - Answer✔N1D2D3 -
PAGE 1-8
What is a Process Indicator - Answer✔A condition that identifies a characteristics that does not
affect the form fit or function of a product- should be monitored
Conditions that are not specified as defective or as a process indicator are considered -
Answer✔Acceptable - Page 1-4
Illumination at the surface of workstation should be minimum of - Answer✔1000 lm/m^2 or 93
foot candles
A condition that is close to perfect defines what type of condition - Answer✔Target
When inspecting a 22 AWG wire the inspection magnification range shall be - Answer✔1.5X-3X
- Table 1-1
1
, ©FYNDLAY 2024/2025 ALL RIGHTS RESERVED 12:27AM. A+
The criteria defined in IPC-620 reflect three product classes , Class 1, 2, 3 - Answer✔Class 1-
General Electronic Products
Class 2- Dedicated Service Electronic Products
Class 3- High Performance/ Harsh Environment Electronic Products
If insulation thickness is reduced by more than 20%, the condition is _1_2_3 - Answer✔Defect
for all classes - Chapter 3 - page 3-9
Damaged wires that do not exceed the limits specified in table 3-1 are considered _1_2_3 -
Answer✔A1P2P3 so process indicators for 2 and 3 -Page 3-2
Wire separation that exceeds one strand diameter but does not extend beyond the wire
insulation outside diameter is _1_2_3 - Answer✔A1P2D3 Chapter 3 page 3-6
The maximum number of damaged strands for Class 2 wires with 28 strands used at a potential
of 6kV or greater is - Answer✔0 - Chapter 3, refer to Table 3-1
Insulation that has been charred, melted into the wire strands and has uneven or ragged pieces
of insulation that is greater than 50% of the outside diameter or 1 mm, is what for all classes -
Answer✔Defect
If a wire has 20 strands, the maximum allowable scraped, nicked, or severed strands for a Class
2 crimp termination is - Answer✔3 - Chapter 3 Table 3-1
When twisting a wires in a cable bundle is required, the length of lay for each twist shall be _ to
_ the other diameter of the bundle - Answer✔8 to 16 times - Chapter 3 page 3-7
If the wire strands are kinked, what is it for all classes? - Answer✔Defect for all, chapter 3 page
3-6
Stranded wires used in what three types shall never be tinned? - Answer✔1. Crimped
termination
2. Mesh Splices
3. Threaded Fasteners
Chapter 4 page 4-12
A wire not discernible in a pierced terminal solder connection is what for all classes? -
Answer✔A1P2P3, Chapter 4 Page 4-37
A part with gold plating thickness that exceeds 2.5 um and has not had the gold removed from
areas to be soldered is what for all classes? - Answer✔N1D2D3 - Chapter 4, page 4-5 / for
Solder cups, gold shall only be removed for Class 3 N1N2D3
2