100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Home Inspection State Exam Questions With Correct Answers 100% Verified.

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
10-02-2025
Written in
2024/2025

©THESTAR 2024/2025 ALL RIGHTS RESERVED 1:00PM. A+ 1 Home Inspection State Exam Questions With Correct Answers 100% Verified. If water infiltration is suspected behind a finished surface. What tool would be the best choice to verify dampness? - AnswerA non-contact moisture meter Gas fired furnace heat exchangers most often fail from? - AnswerRust and metal fatigue Relative Humditiy (RH) is expressed as? - AnswerPercentage Connections of dissimilar metal in plumbing system, such as galvanized steel pipe and copper pipe, will usually cause? - AnswerElectrolysis Which has the least effect on the deflection of a dimension lumber floor system? - AnswerJoist width The normal MAXIMUM rise of residential stair treads is ? - Answer7 3/4 inches An ungrounded receptacle May be replaced by a ground fault circuit interrupter installed? - AnswerUpstream from the receptacle Circuit breakers protect the wire from? - AnswerAn electrical overload In a forced air heating system containing a split system air conditioner and a humidifier, humidity is reduced by? - AnswerCondensation at the evaporator coil A home inspection MUST include the type of roof material and ? - AnswerThe method of observation Water hammer can occur as a result of ? - AnswerA lack of air chambers If a system designed for use with natural gas is supplied with propane gas? - AnswerThe flame will be too high unless a smaller orifice is installed When looking at the exterior wall of a 60 year old brick masonry house with a gable roof, you notice a horizontal crack in the mortar and onward brick displacement along the gutter edge of ©THESTAR 2024/2025 ALL RIGHTS RESERVED 1:00PM. A+ 2 the roof. The displacement is greater at the center of the top three courses of brick. This condition is most likely caused by ? - AnswerImproper ceiling joist installation You inspect a word framed cantilevered balcony of a second story bedroom. You find significant wood deterioration ( at least one half member depth) of all cantilever joists at the bearing point of the house. You should? - AnswerNotify the occupants of the significant hazard, advise immediate repair to both the occupant and client in the report. When a cooling unit is located in an attic where damage may result from condensate overflow? - AnswerAn auxiliary condensate drain system is required Asphalt shingles are NOT allowed to be installed on roofs with slopes less than? - Answer2in 12. If a poured concrete foundation has an usually large number of vertical cracks, each no wider than 1/32 inch, the cause is likely to be? - AnswerShrinkage of the concrete from excess water at the time of pouring. Where should squash blocks(web blocking) be found in a wood I-joist floor system? - AnswerAt bearing ends and load bearing walls above with support girders below. Columns typically support what? - AnswerGirders In a new construction, the minimum overhead electrical service clearances are? - AnswerWalkway: 10ft roadway: 18ft deck: 10ft During a summertime inspection, what could indicate chronic condensation problems in an attain? - AnswerThere are gray/black stains on the north side roof sheathing. Ice damming at the eaves may be caused by? - AnswerInadequate attic insulation The purpose of flashing on a roof is to? - AnswerShed Water onto roofing materials The house you are inspecting currently has a gas fired furnace or boiler. Each of the following clues may indicate that the house also has an abandoned buried if you were oil storage tank except ? - AnswerThe brick chimney serving the furnace or boiler has deteriorated mortar joints at the bottom. While inspecting a heat pump in the cooling mode, you measure 28°F temperature differential between the interior supply and return air. You should suspect? - AnswerDirty filter What is the minimum electrical service drop clearance from a residential driveway? - Answer12 ft Roof truss uplift can cause cracks to form at? - AnswerInterio

Show more Read less
Institution
Home Inspector
Course
Home inspector









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Home inspector
Course
Home inspector

Document information

Uploaded on
February 10, 2025
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©THESTAR 2024/2025 ALL RIGHTS RESERVED 1:00PM. A+




Home Inspection State Exam Questions With
Correct Answers 100% Verified.




If water infiltration is suspected behind a finished surface. What tool would be the best choice
to verify dampness? - Answer✔A non-contact moisture meter

Gas fired furnace heat exchangers most often fail from? - Answer✔Rust and metal fatigue

Relative Humditiy (RH) is expressed as? - Answer✔Percentage
Connections of dissimilar metal in plumbing system, such as galvanized steel pipe and copper
pipe, will usually cause? - Answer✔Electrolysis
Which has the least effect on the deflection of a dimension lumber floor system? -
Answer✔Joist width

The normal MAXIMUM rise of residential stair treads is ? - Answer✔7 3/4 inches
An ungrounded receptacle May be replaced by a ground fault circuit interrupter installed? -
Answer✔Upstream from the receptacle

Circuit breakers protect the wire from? - Answer✔An electrical overload
In a forced air heating system containing a split system air conditioner and a humidifier,
humidity is reduced by? - Answer✔Condensation at the evaporator coil

A home inspection MUST include the type of roof material and ? - Answer✔The method of
observation

Water hammer can occur as a result of ? - Answer✔A lack of air chambers

If a system designed for use with natural gas is supplied with propane gas? - Answer✔The flame
will be too high unless a smaller orifice is installed
When looking at the exterior wall of a 60 year old brick masonry house with a gable roof, you
notice a horizontal crack in the mortar and onward brick displacement along the gutter edge of

1

, ©THESTAR 2024/2025 ALL RIGHTS RESERVED 1:00PM. A+


the roof. The displacement is greater at the center of the top three courses of brick. This
condition is most likely caused by ? - Answer✔Improper ceiling joist installation
You inspect a word framed cantilevered balcony of a second story bedroom. You find significant
wood deterioration ( at least one half member depth) of all cantilever joists at the bearing point
of the house. You should? - Answer✔Notify the occupants of the significant hazard, advise
immediate repair to both the occupant and client in the report.
When a cooling unit is located in an attic where damage may result from condensate overflow?
- Answer✔An auxiliary condensate drain system is required

Asphalt shingles are NOT allowed to be installed on roofs with slopes less than? - Answer✔2in
12.
If a poured concrete foundation has an usually large number of vertical cracks, each no wider
than 1/32 inch, the cause is likely to be? - Answer✔Shrinkage of the concrete from excess water
at the time of pouring.
Where should squash blocks(web blocking) be found in a wood I-joist floor system? -
Answer✔At bearing ends and load bearing walls above with support girders below.

Columns typically support what? - Answer✔Girders
In a new construction, the minimum overhead electrical service clearances are? -
Answer✔Walkway: 10ft roadway: 18ft deck: 10ft
During a summertime inspection, what could indicate chronic condensation problems in an
attain? - Answer✔There are gray/black stains on the north side roof sheathing.

Ice damming at the eaves may be caused by? - Answer✔Inadequate attic insulation

The purpose of flashing on a roof is to? - Answer✔Shed Water onto roofing materials
The house you are inspecting currently has a gas fired furnace or boiler. Each of the following
clues may indicate that the house also has an abandoned buried if you were oil storage tank
except ? - Answer✔The brick chimney serving the furnace or boiler has deteriorated mortar
joints at the bottom.
While inspecting a heat pump in the cooling mode, you measure 28°F temperature differential
between the interior supply and return air. You should suspect? - Answer✔Dirty filter
What is the minimum electrical service drop clearance from a residential driveway? -
Answer✔12 ft

Roof truss uplift can cause cracks to form at? - Answer✔Interior wall/ceiling intersections


2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar Florida State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
610
Member since
2 year
Number of followers
178
Documents
24049
Last sold
22 hours ago
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

121 reviews

5
58
4
21
3
21
2
4
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions