100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

CML Test Exam Questions With Correct Answers 100% Verified.

Rating
-
Sold
1
Pages
7
Grade
A+
Uploaded on
10-02-2025
Written in
2024/2025

©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+ 1 CML Test Exam Questions With Correct Answers 100% Verified. Which of the following are typical schedules found on Construction Drawing sets? - AnswerDoor, Light Fixture, Panelboard, Room finish, Window The portion of the construction drawing set that includes less visual and more text based information about a project is the - AnswerSpecifications In the most recent reorganization of construction specifications, the electrical information is found primarily in section - Answer26 TRUE or FALSE: Because there is no room allocated for expansion (or growth through the creation of new sections) new sections can only be added at the subsequent of the Masterformat. specific information and requirements for HVAC piping heat tracing would be located in Master Format section,,, - AnswerFalse 23 05 33 In the 2004 version, there are ? groups that contain all of the subgroups. A request for an interpretation of the contract that may initiate contract modification would be explained in the MasterFormat section ? - Answer2 01 26 13 true or false: in the 2004 version of MasterFormat each section number has four digits instead of the prior versions that had six digits. Specifications for commercial washers and extractors would be found in MasterFormat section ? - Answerfalse 11 23 26 ©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+ 2 The masonry division is a part of the ? subgroup in the 2004 MasterFormat. The Requirements for epoxy coated reinforcing steel are located in MasterFormat section ? - AnswerFacility Construction 03 21 16 In the NIST residence, which window types are awning windows? Select all that apply. - Answerd f g In which of the following areas is DWH-2 located? Enter the grid location where it is located on the plan. - AnswerIn the garage E-103: P12 Which circuit number and electrical panel listed below supply DWH-2? Provide the grid location where the specifications for the disconnecting means are located. - AnswerCircuit 17, Panel RP-G E-103: p11 There is only one door type 12 used in the NIST residence. What type of door is Door 12? Provide the grid location where this information is given on the prints. - Answerpocket E-103: P12 The builder must submit two 12 inch x ? samples for each type of finish coating for the architects review of color and texture only. Provide the location of where this information is found in the specifications. - Answer8" 09 90 00:1.4:b:3 Molded-case circuit breaker shunt trips must have 120-volt coils energized from a separate circuit and set to trip at ? of the rated voltage. Provide the location of where this information is found in the specifications. - Answer55% 26 24 16:2.3:b:4:e fixture support wires for humid spaces must meet the following requirements: ASTM A 580/A 580M, Composition 302 or 304, annealed stainless steel, ?. Provide the location of where this information is found in the specifications. - An

Show more Read less
Institution
CML
Course
CML









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CML
Course
CML

Document information

Uploaded on
February 10, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+




CML Test Exam Questions With Correct
Answers 100% Verified.


Which of the following are typical schedules found on Construction Drawing sets? -
Answer✔Door, Light Fixture, Panelboard, Room finish, Window
The portion of the construction drawing set that includes less visual and more text based
information about a project is the - Answer✔Specifications
In the most recent reorganization of construction specifications, the electrical information is
found primarily in section - Answer✔26
TRUE or FALSE: Because there is no room allocated for expansion (or growth through the
creation of new sections) new sections can only be added at the subsequent of the
Masterformat.


specific information and requirements for HVAC piping heat tracing would be located in Master
Format section,,, - Answer✔False
23 05 33
In the 2004 version, there are ? groups that contain all of the subgroups. A request for an
interpretation of the contract that may initiate contract modification would be explained in the
MasterFormat section ? - Answer✔2
01 26 13
true or false: in the 2004 version of MasterFormat each section number has four digits instead
of the prior versions that had six digits.


Specifications for commercial washers and extractors would be found in MasterFormat section
? - Answer✔false
11 23 26

1

, ©THESTAR 2024/2025 ALL RIGHTS RESERVED 11:42PM. A+


The masonry division is a part of the ? subgroup in the 2004 MasterFormat. The Requirements
for epoxy coated reinforcing steel are located in MasterFormat section ? - Answer✔Facility
Construction


03 21 16
In the NIST residence, which window types are awning windows? Select all that apply. -
Answer✔d
f
g
In which of the following areas is DWH-2 located? Enter the grid location where it is located on
the plan. - Answer✔In the garage
E-103: P12
Which circuit number and electrical panel listed below supply DWH-2? Provide the grid location
where the specifications for the disconnecting means are located. - Answer✔Circuit 17, Panel
RP-G
E-103: p11
There is only one door type 12 used in the NIST residence. What type of door is Door 12?
Provide the grid location where this information is given on the prints. - Answer✔pocket
E-103: P12
The builder must submit two 12 inch x ? samples for each type of finish coating for the
architects review of color and texture only. Provide the location of where this information is
found in the specifications. - Answer✔8"
09 90 00:1.4:b:3
Molded-case circuit breaker shunt trips must have 120-volt coils energized from a separate
circuit and set to trip at ? of the rated voltage. Provide the location of where this information is
found in the specifications. - Answer✔55%
26 24 16:2.3:b:4:e
fixture support wires for humid spaces must meet the following requirements: ASTM A 580/A
580M, Composition 302 or 304, annealed stainless steel, ?. Provide the location of where this
information is found in the specifications. - Answer✔2.68mm
26 51 00:2.6:e

2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar Florida State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
591
Member since
1 year
Number of followers
178
Documents
23587
Last sold
1 day ago
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

119 reviews

5
56
4
21
3
21
2
4
1
17

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions