API 653 Recertification Quiz with 100% Correct Answers | Latest Version | Expert Verified | Ace the Test  When installing a new nozzle in a tank of unknow material, what stress value should be used to calculate the required shell thickness and reinforcement? - ANSWER -20,000 lbf/in2 In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a wet environment. - ANSWER -may double with every 18 °F increase in temperature above 77 °F. Grade 350W/50W is acceptable for tank plate to a maximum thickness of: - ANSWER -45mm (1.75in) if fully killed and made to a fine grain practice. If an RBI assessment has been conducted and the tank has a release prevention barrier, the maximum initial inspection interval is: - ANSWER -25 years As an alternative to the procedures in API 653 for the evaluation of any thinning of the tank shell below minimum required wall thickness may be evaluated for continued service using which code? - ANSWER -API RP 579, section 4, 5 or 6. When welding on a tank shell constructed of Group I steel that is greater than 1.5 inches thick below what minimum metal temperature ?preheat? - ANSWER - 200°F When evaluated an existing temperature services tank, which has a successful service history of operation but was not originally designed and constructed to the requirement of API 650, appendix M, which condition temperature has to be used? - ANSWER -The max Operating Temperature shall not exceed the temperature at which the tank has successfully operated in the pass. Flange material used for tank repair and alteration shall meet the minimum requirements for the material specifications according to: - ANSWER -The as built standard which is an advantage of thick film UN-REINFORCED linings ? - ANSWER - Fast curing and can be put back in service after 24 hours at normal ambient temperature. The perimeter welds on a welded-on patch plate in the critical zone should be ? - ANSWER -Two-pass and examined visually and by either MP or PT. Existent welds on a tank shell are found to e closer than allowed by API 650 (7th Edition). Under what conditions can these welds be considered to be acceptable for continued service? - ANSWER -Examined by MP inspection with no rejectable indications. The requirements of which standard shall be considered in the evaluation and alteration to the tank roof and roof-to-shell junction ? - ANSWER -Current applicable standard Welding procedure for ladder and platform assemblies, but not their attachment to the tank? - ANSWER -Shall comply with either AWS D1.1, AWS D1.6 or ASME Code Section IX.

Show more Read less
Institution
API 653 Recertification
Course
API 653 Recertification









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
API 653 Recertification
Course
API 653 Recertification

Document information

Uploaded on
February 7, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

API 653 Recertification Quiz with 100% Correct
Answers | Latest Version | Expert Verified | Ace the
Test





When installing a new nozzle in a tank of unknow material, what stress value
should be used to calculate the required shell thickness and reinforcement? -
ANSWER -20,000 lbf/in2


In regards to underside corrosion on tank bottoms, the corrosion rate of steel in a
wet environment. - ANSWER -may double with every 18 °F increase in
temperature above 77 °F.


Grade 350W/50W is acceptable for tank plate to a maximum thickness of: -
ANSWER -45mm (1.75in) if fully killed and made to a fine grain practice.


If an RBI assessment has been conducted and the tank has a release prevention
barrier, the maximum initial inspection interval is: - ANSWER -25 years


As an alternative to the procedures in API 653 for the evaluation of any thinning
of the tank shell below minimum required wall thickness may be evaluated for
continued service using which code? - ANSWER -API RP 579, section 4, 5 or 6.


When welding on a tank shell constructed of Group I steel that is greater than 1.5
inches thick below what minimum metal temperature ?preheat? - ANSWER -
200°F

, When evaluated an existing temperature services tank, which has a successful
service history of operation but was not originally designed and constructed to the
requirement of API 650, appendix M, which condition temperature has to be used?
- ANSWER -The max Operating Temperature shall not exceed the temperature at
which the tank has successfully operated in the pass.


Flange material used for tank repair and alteration shall meet the minimum
requirements for the material specifications according to: - ANSWER -The as built
standard


which is an advantage of thick film UN-REINFORCED linings ? - ANSWER -
Fast curing and can be put back in service after 24 hours at normal ambient
temperature.


The perimeter welds on a welded-on patch plate in the critical zone should be ? -
ANSWER -Two-pass and examined visually and by either MP or PT.


Existent welds on a tank shell are found to e closer than allowed by API 650 (7th
Edition). Under what conditions can these welds be considered to be acceptable for
continued service? - ANSWER -Examined by MP inspection with no rejectable
indications.


The requirements of which standard shall be considered in the evaluation and
alteration to the tank roof and roof-to-shell junction ? - ANSWER -Current
applicable standard

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
125
Member since
1 year
Number of followers
5
Documents
3201
Last sold
1 day ago
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.5

16 reviews

5
8
4
2
3
1
2
0
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions