On a flammable liquid fire of a depth that is more than 6mm such as in a large tank, the best results are obtained when the fire extinguisher discharge is directed? A) in front of the fire B) directly on the fire C) against the back wall of the tank D) at the base of the fire correct answersC Fire pumps usually start based on? A) fire department hooking up to the system B) loss of standpipe/sprinkler system pressure C) operator activated at a remote pump station D)operator activated at a local pump station correct answersB Class 3 standpipe systems have? A) 100mm hose connections B) 40mm hose connections C) 40mm & 65mm hose connections D) 50mm & 100mm hose connections correct answersC Deluge sprinkler systems have? (Select 2) A) non heat activated sprinkler heads B) heat activated sprinkler heads C) automatic sprinkler heads D) non automatic sprinkler heads correct answersA, D The purpose of a jockey pump in a fire suppression system is? A) to circulate sprinkler water when the system is not activated B) to keep the system pressurized above the starting pressure of the fire pump C) provide cooling to fire suppression system components D) to provide reliable flow of water for fire hoses and sprinklers correct answersB The best method of dealing with a fire is? A) fire department B) fire detector C) fire extinguishers

Show more Read less
Institution
Bcit Practice Qui34
Course
Bcit practice qui34










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Bcit practice qui34
Course
Bcit practice qui34

Document information

Uploaded on
February 4, 2025
Number of pages
24
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

Bcit practice quizzes

On a flammable liquid fire of a depth that is more than 6mm such as in a
large tank, the best results are obtained when the fire extinguisher
discharge is directed?

A) in front of the fire
B) directly on the fire
C) against the back wall of the tank
D) at the base of the fire correct answersC

Fire pumps usually start based on?

E) fire department hooking up to the system
F) loss of standpipe/sprinkler system pressure
G) operator activated at a remote pump station
H)operator activated at a local pump station correct answersB

Class 3 standpipe systems have?

I) 100mm hose connections
J) 40mm hose connections
K) 40mm & 65mm hose connections
L) 50mm & 100mm hose connections correct answersC

Deluge sprinkler systems have? (Select 2)

M)non heat activated sprinkler heads
N) heat activated sprinkler heads
O) automatic sprinkler heads
P) non automatic sprinkler heads correct answersA, D

The purpose of a jockey pump in a fire suppression system is?

Q) to circulate sprinkler water when the system is not activated
R) to keep the system pressurized above the starting pressure of the fire
pump
S) provide cooling to fire suppression system components
T) to provide reliable flow of water for fire hoses and sprinklers correct
answersB

The best method of dealing with a fire is?

U) fire department
V) fire detector
W)fire extinguishers

,D) preventing the fire from occurring correct answersD

Select from the following method that can be used in the prevention of class
B fires

A) continually monitor the temperature of cooling oil while the cooling
station is in use
B) boiler fuel oil systems near the burner should be kept free of oil
C) store combustible metals away from potential ignition sources
D) do not put flammable material near electrical equipment correct
answersB

Which of the following is an oxidizing agent?

E) phosphorus
F) hydrogen peroxide
G) zirconium
H) hydrogen correct answersB

A carbon dioxide fire extinguisher removes which of the four
components of the fire tetrahedron to extinguish a fire

I) uninhibited chain reaction
J) fuel
K) oxygen
L) ignition source correct answersC

The goal of the global harmonized system of classification and labelling of
chemicals is to adopt and use the same set of rules for classifying hazards
and the same format and content for label and safety data sheets around
the world

M)True
N)False correct answersA

When utilizing hazardous materials in a workplace the worker is
responsible for all of the following except

O) protect themselves and their coworkers
P) ensure that labels are in good condition
Q) classify products by labelling
R) participate in training and education correct answersC

Designated evacuation routes and muster areas can be found in

S) occupational health and safety
T) emergency response plan
U) hazard assessment
V) confined space entry procedure correct answersB

, A hot work permit is issued when (select 2)

A) work produces an indirect ignition source
B)the area is not designed or intended for human occupancy except for
the purpose of performing work
C) for general maintenance work that does not produce an ignition source
D) work that produces a direct ignition source correct answersA,D

An occupational health and safety program can be defined as an
organized plan to (select 3)

E) prevent workplace related accidents and occupational diseases
F) proactively identify and control hazards
G) respond to emergencies
H) increase production efficiency correct answersA,B,C

A safe work permit attempts to identify any risk associated with a job
and specifies

I) safety officers
J) personal protective equipment required at the plant
K) time needed to complete the work
L) control measures needed to mitigate the hazards correct answersD

Hazard controls are developed by using information collected from

M)workplace surveys
N) hazard assessment process
O) joint workplace health and safety committee
P) Canadian occupational health and safety legislation correct answersB

Class 3 electrical locations

Q)are concerned with the presence of combustible solid material that
can exist in an explosive amount
R)are concerned with the presence of combustible dusts that can exist
in explosive concentrations
S)must be designed to be fire safe in any area where there may be the
presence of flammable gases or vapours
T)involve the presence of airborne material fibres that are easily
ignited correct answersD

During a fire additional precautions must be taken when entering an
enclosed fire area because (select 2)

U) fire can resume rapidly if air is introduced when the door is opened
V) fresh oxygen feeds the hot combustible gases and can result in an
explosion

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HopeJewels Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
70
Member since
1 year
Number of followers
10
Documents
8653
Last sold
2 days ago
macellen education agencies

On this page, you find all documents,testsbank ,solution manuals, package deals, On this page, you find all documents, package deals, and flashcards offered by seller Hopejewels

3.2

5 reviews

5
2
4
0
3
1
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions