100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed

Rating
-
Sold
-
Pages
4
Grade
A+
Uploaded on
01-02-2025
Written in
2024/2025

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed Type 3 - Answers Technicians maintaining, servicing, repairing or disposing of low-pressure appliances must be certified as a universal technician or a _______ ___. enter - Answers Because a low-pressure system operates below atmospheric pressure (in a vacuum), leaks in the gaskets or fittings will cause air and moisture to ______ the system. heater - Answers The most efficient method of leak checking a charged, low-pressure refrigeration unit is to pressurize the system by the use of controlled hot water or ______ blankets. nitrogen - Answers When unable to heat a low-pressure system for leak-checking, use ______ to increase pressure. 10 - Answers When pressurizing a low-pressure system with nitrogen, do not exceed _____ psig. rupture - Answers Exceeding 10 psig when pressurizing a low-pressure system, can cause the _____ disc to fail. removed - Answers When leak testing a water box, be certain the water has been ______ before placing the leak detector probe through the drain valve. hydrostatic - Answers When leak-testing a tube, use a _______ tube test kit. seal - Answers Systems with open drive compressors are prone to leaks at the shaft _____. hot - Answers For the purpose of opening the system for a non-major repair, controlled ______ water can be used to pressurize a system. high pressure - Answers A recovery unit's _____ _____ cut-out is set for 10 psig when evacuating the refrigerant from a low-pressure chiller. 15 - Answers A low-pressure chiller and a rupture disc on a low-pressure recovery vessel relieves at _____ psig. liquid vapor - Answers Refrigerant recovery from a system using R-11 or R-123 starts with ______ removal and is followed by _____ recovery. vapor - Answers A substantial amount of _____ will remain in the appliance after all liquid is removed. 100 - Answers An average 350 ton R-11 chiller at 0 psig still contains _____ lbs. of vapor after all the liquid has been removed. circulated - Answers Water must be ______ through the tubes when evacuating refrigerant in order to prevent freezing the water. condenser - Answers Most low-pressure recovery machines utilize a water-cooled ______ that is connected to the municipal water supply. on - Answers When recovering refrigerant, the system water pumps, the recovery compressor, and the recovery condenser water should all be ______. drained - Answers If a chiller is suspected of tube leaks, the water sides of the evaporator and condenser should be ______ prior to recovering the refrigerant. 2.5 - Answers The ASHRAE Guideline 3-1996 states that if the pressure in a system rises from 1 mm Hg to a level above ____ mm Hg during vacuum testing, the system should be leak checked. 130 - Answers A temperature of _____ F should be attained when removing oil from a low-pressure system. oil - Answers Less refrigerant is contained in the _____ at the higher temperature of 130 degrees

Show more Read less
Institution
EPA 608 Type 3
Course
EPA 608 Type 3








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 Type 3
Course
EPA 608 Type 3

Document information

Uploaded on
February 1, 2025
Number of pages
4
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EPA 608 Type 3 Exam Questions Fully Solved Latest Update 2025 Already Passed

Type 3 - Answers Technicians maintaining, servicing, repairing or disposing of low-pressure appliances
must be certified as a universal technician or a _______ ___.

enter - Answers Because a low-pressure system operates below atmospheric pressure (in a vacuum),
leaks in the gaskets or fittings will cause air and moisture to ______ the system.

heater - Answers The most efficient method of leak checking a charged, low-pressure refrigeration unit
is to pressurize the system by the use of controlled hot water or ______ blankets.

nitrogen - Answers When unable to heat a low-pressure system for leak-checking, use ______ to
increase pressure.

10 - Answers When pressurizing a low-pressure system with nitrogen, do not exceed _____ psig.

rupture - Answers Exceeding 10 psig when pressurizing a low-pressure system, can cause the _____ disc
to fail.

removed - Answers When leak testing a water box, be certain the water has been ______ before placing
the leak detector probe through the drain valve.

hydrostatic - Answers When leak-testing a tube, use a _______ tube test kit.

seal - Answers Systems with open drive compressors are prone to leaks at the shaft _____.

hot - Answers For the purpose of opening the system for a non-major repair, controlled ______ water
can be used to pressurize a system.

high pressure - Answers A recovery unit's _____ _____ cut-out is set for 10 psig when evacuating the
refrigerant from a low-pressure chiller.

15 - Answers A low-pressure chiller and a rupture disc on a low-pressure recovery vessel relieves at
_____ psig.

liquid vapor - Answers Refrigerant recovery from a system using R-11 or R-123 starts with ______
removal and is followed by _____ recovery.

vapor - Answers A substantial amount of _____ will remain in the appliance after all liquid is removed.

100 - Answers An average 350 ton R-11 chiller at 0 psig still contains _____ lbs. of vapor after all the
liquid has been removed.

circulated - Answers Water must be ______ through the tubes when evacuating refrigerant in order to
prevent freezing the water.

condenser - Answers Most low-pressure recovery machines utilize a water-cooled ______ that is
connected to the municipal water supply.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
328
Member since
1 year
Number of followers
16
Documents
28195
Last sold
3 hours ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

52 reviews

5
18
4
14
3
11
2
0
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions