100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Type 2 Exam Questions Fully Solved Latest Update 2025 Already Passed

Rating
-
Sold
-
Pages
8
Grade
A+
Uploaded on
01-02-2025
Written in
2024/2025

EPA 608 Type 2 Exam Questions Fully Solved Latest Update 2025 Already Passed Technicians maintaining, servicing, repairing or disposing of high pressure or very high-pressure appliances, except small appliances and MVAC, must be certified either as a Universal Technician or a ______ ___. - Answers Type 2 After the installation of any type of system, the unit should be pressurized with _____ and _____ checked. - Answers nitrogen leak Nitrogen is an ______ gas. - Answers inert In order to determine the general area of a leak, technicians should use a _____ or _____ leak detector. - Answers electronic ultrasonic After locating the general area of a leak, ______ ______ are used to pinpoint it. - Answers soap bubbles A refrigeration unit using an open compressor that has not been used in several months is likely to leak from the rotating shaft ______. - Answers seal During a visual inspection of any type of system, _____ of _____ are an indicator of a refrigerant leak. - Answers traces oil Excessive ________, caused by a low refrigerant charge, is an indication of a leak in a high-pressure system. - Answers superheat A low ______ _______ may be the cause of excessive superheat in a high-pressure system. - Answers refrigerant charge Epa regulations require that all comfort cooling appliances containing more than _____ lbs. of refrigerant MUST be repaired when the annual leak rate exceeds _____ %. - Answers 50 15 Epa regulations require that all commercial and industrial process refrigeration systems containing more than _____ lbs. of refrigerant MUST be repaired when the annual leak rate exceeds _____ %. - Answers 50 35 Recovered refrigerants may contain _____, moisture, and oil. - Answers acids Recovered refrigerants may contain acids, ______, and oil. - Answers moisture Recovered refrigerants may contain acids, moisture, and ________. - Answers oil Because of the acids, moisture, and oil that may be in recovered refrigerants, it is necessary to frequently check and change both the _____ and _____ on recycling machines. - Answers oil filter Recycling and Recovery machines using ______ compressors may overheat when pulling a deep vacuum. - Answers hermetic Recycling and Recovery machines using hermetic compressors may overheat when pulling a deep vacuum because the unit relies on the flow of ______ through the compressor for ______. - Answers refrigerant cooling Before using a recovery unit, you should always check the _______ _______ _______, the oil level of the unit, and evacuate and recover any remaining refrigerant in the unit's receiver. - Answers service valve positions Before using a recovery unit, you should always check the service valve positions, the _____ _____ of the unit, and evacuate and recover an remaining refrigerant in the unit's receiver. - Answers oil level Before using a recovery unit, you should always check the service valve positions, the oil level of the unit and evacuate and recover an remaining refrigerant in the unit's ________. - Answers receiver Technicians working with multiple refrigerants, before recovering and/or recycling a different refrigerant, must ______ the recover/recycle equipment by recovering as much of the first refrigerant as possible, change the filter, and evacuate. Exception: technicians working with R - 134 A. - Answers purge Technicians working with multiple refrigerants, before recovering and/or recycling a different refrigerant, must purge the recover/recycle equipment by ______ as much of the first refrigerant as possible, change the filter, and evacuate. Exception: technicians working with R - 134 A. - Answers recovering Technicians working with multiple refrigerants, before recovering and/or recycling a different refrigerant, must purge the recover/recycle equipment by recovering as much of the first refrigerant as possible, change the ______, and evacuate. Exception: technicians working with R -

Show more Read less
Institution
EPA 608 Type 2
Course
EPA 608 Type 2









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 Type 2
Course
EPA 608 Type 2

Document information

Uploaded on
February 1, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EPA 608 Type 2 Exam Questions Fully Solved Latest Update 2025 Already Passed

Technicians maintaining, servicing, repairing or disposing of high pressure or very high-pressure
appliances, except small appliances and MVAC, must be certified either as a Universal Technician or a
______ ___. - Answers Type 2

After the installation of any type of system, the unit should be pressurized with _____ and _____
checked. - Answers nitrogen leak

Nitrogen is an ______ gas. - Answers inert

In order to determine the general area of a leak, technicians should use a _____ or _____ leak detector.
- Answers electronic ultrasonic

After locating the general area of a leak, ______ ______ are used to pinpoint it. - Answers soap bubbles

A refrigeration unit using an open compressor that has not been used in several months is likely to leak
from the rotating shaft ______. - Answers seal

During a visual inspection of any type of system, _____ of _____ are an indicator of a refrigerant leak. -
Answers traces oil

Excessive ________, caused by a low refrigerant charge, is an indication of a leak in a high-pressure
system. - Answers superheat

A low ______ _______ may be the cause of excessive superheat in a high-pressure system. - Answers
refrigerant charge

Epa regulations require that all comfort cooling appliances containing more than _____ lbs. of
refrigerant MUST be repaired when the annual leak rate exceeds _____ %. - Answers 50 15

Epa regulations require that all commercial and industrial process refrigeration systems containing more
than _____ lbs. of refrigerant MUST be repaired when the annual leak rate exceeds _____ %. - Answers
50 35

Recovered refrigerants may contain _____, moisture, and oil. - Answers acids

Recovered refrigerants may contain acids, ______, and oil. - Answers moisture

Recovered refrigerants may contain acids, moisture, and ________. - Answers oil

Because of the acids, moisture, and oil that may be in recovered refrigerants, it is necessary to
frequently check and change both the _____ and _____ on recycling machines. - Answers oil filter

Recycling and Recovery machines using ______ compressors may overheat when pulling a deep vacuum.
- Answers hermetic

, Recycling and Recovery machines using hermetic compressors may overheat when pulling a deep
vacuum because the unit relies on the flow of ______ through the compressor for ______. - Answers
refrigerant cooling

Before using a recovery unit, you should always check the _______ _______ _______, the oil level of the
unit, and evacuate and recover any remaining refrigerant in the unit's receiver. - Answers service valve
positions

Before using a recovery unit, you should always check the service valve positions, the _____ _____ of
the unit, and evacuate and recover an remaining refrigerant in the unit's receiver. - Answers oil level

Before using a recovery unit, you should always check the service valve positions, the oil level of the unit
and evacuate and recover an remaining refrigerant in the unit's ________. - Answers receiver

Technicians working with multiple refrigerants, before recovering and/or recycling a different
refrigerant, must ______ the recover/recycle equipment by recovering as much of the first refrigerant as
possible, change the filter, and evacuate. Exception: technicians working with R - 134 A. - Answers purge

Technicians working with multiple refrigerants, before recovering and/or recycling a different
refrigerant, must purge the recover/recycle equipment by ______ as much of the first refrigerant as
possible, change the filter, and evacuate. Exception: technicians working with R - 134 A. - Answers
recovering

Technicians working with multiple refrigerants, before recovering and/or recycling a different
refrigerant, must purge the recover/recycle equipment by recovering as much of the first refrigerant as
possible, change the ______, and evacuate. Exception: technicians working with R - 134 A. - Answers
filter

Technicians working with multiple refrigerants, before recovering and/or recycling a different
refrigerant, must purge the recover/recycle equipment by recovering as much of the first refrigerant as
possible, change the filter, and ______. Exception: technicians working with R - 134 A. - Answers
evacuate

Recovering refrigerant in the vapor phase will minimize the ______ of oil. - Answers loss

Recovering refrigerant in the ______ phase can ______ recovery time. - Answers liquid reduce

The technician may choose to _____ up the recovery process by packing the recovery cylinder in _____
and/or applying heat to the appliance. - Answers speed ice

The technician may choose to speed up the recovery process by packing the recovery cylinder in ice
and/or applying ______ to the appliance. - Answers heat

After recovering refrigerant in the liquid phase, any remaining ______ is _______ by the recovery
system. - Answers vapor condensed

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
328
Member since
1 year
Number of followers
16
Documents
28195
Last sold
3 hours ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

52 reviews

5
18
4
14
3
11
2
0
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions