An off-grid installation has 68KWh
a 1HP pump that is on 10% 1HP = 746W
of the time and a 20W 746W 0.1 24hours * 30days = 53712Wh
light that is on 100% of the 20W 24hrs 30days = 14400Wh
time. What is the monthly 14400 + 53712 = 68112Wh
energy use? 68kWh
DC
Inverters detect dc ground faults. AC ground faults
are detected on the AC side of the inverter at the
What kind of ground faults distribution paned (MSP, load center). Most inverters
do most inverters detect? are not connected to high or medium voltage.
Medium voltage is thousands of volts, large utility
scale inverters are connected to medium voltage via a
transformer
Current carrying ability of Ampacity
a conductor (wire) is
called
https://quizlet.com/999692288/nabcep-pv-associate-retake-exam-guide-already-graded-a-all-questions-and-correct-answers-latest-version-2025-flas… 1/14
, 1/31/25, 12:46 PM NABCEP PV ASSOCIATE RETAKE EXAM GUIDE | ALREADY GRADED A+ | ALL QUESTIONS AND CORRECT ANSWERS | LA…
According to ohms law Proportional. Ohms law: V = I*R
and voltage drop, the More current makes more voltage drop. This is a
relationship between reason why we need a larger wire with more current,
voltage drop and current so the wire resistance is less with a larger wire and
is there will be less voltage drop.
An array in a hot and dry C) String size too short. When it is hot, voltage can be
place is not producing as low. Too long of a string would be a problem when it
expected in summer time. is too cold not too hot.
Which of the following is
NOT a likely problem:
a) Decreased ac wire size
and voltage loss
b) String size too short
C) String size too long
D) Soiling
When using a digital Inspect the meter. Always inspect first, look before
multimeter, what is the first you touch
thing you should do?
is the worst design error? D) Different tilt or azimuth operation within a source
A) BIPV on a commercial circuit is bad. Series connections should not have
job different orientations
B) A fast-growing tree to
the north of an array in
Idaho
C) PV at 5-degree tilt at 40
degrees latitude
D) Different tilt angles in a
PV source circuit
MPPT is maximum power point tracking and will
optimize the energy harnessed from PV. Some
MPPT is for
inverters have multiple MPPTs. Charge controllers
often, but don't always, have MPPTs