100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Load calculation Feeders and services Level 4 Module 1 exam 2025 with 100% correct answers

Rating
-
Sold
-
Pages
4
Grade
A+
Uploaded on
29-01-2025
Written in
2024/2025

What is the demand factor allowed by the NEC® for calculating the neutral conductor size for electric range load? - correct answer️️70% Using the VA/linear foot method, the total VA that must be used in a service calculation for a 50' show window is - correct answer️️12,500VA Before it is considered a continuous load, a load must operate for at least how many hours without interruption? - correct answer️️3 Which of the following factors does not affect conductor ampacity adjustments? - correct answer️️Number of phase If a continuous connected load totals 120A, what is the minimum current-carrying capacity required for the feeder? - correct answer️️150A What is the load center length for a tapped feeder with loads of 120A at 50', 110A at 60', 75A at 90', and 70A at 150'? - correct answer️️79.60 Which of the following lighting loads would be used in a residence that is 1,650 sq ft? - correct answer️️4,950VA What is the load for 40 non-dwelling unit receptacles? (Assume that the load is not continuous.) - correct answer️️7,200VA The minimum service rating for a residential service is - correct answer️️100A Residential small appliance circuit must be rated at - correct answer️️1,500VA Use of the 100' tap rule is limited to installation in high-bay manufacturing buildings with wall heignt over - correct answer️️35 feet Which part of a residential lighting and small appliance load must be rated at 35% for service calculations? - correct answer️️The next 177,000VA If a store lighting load is 14,000VA (continuous), which of the following must be used for the circuit calculation? - correct answer️️17,500VA In most cases, feeder conductor size is adjusted when - correct answer️️there are more than three current-carrying conductors in the raceway When calculating the service requirement for a particular building, the step is to - correct answer️️determine the floor area of the building What is the feeder ampacity for a three-phase, 120/208V subpanel with a connected load of 84,563VA? - correct answer️️235A Which part of a residential lighting and small appliance load must be rated at 35% for servives - correct answer️️ An optional method for determining feeder to schools is covered in - correct answer️️NEC® Section 220.86 Refer to the figure above. What is the total load of a feeder serving four 230V motors rated 5hp, 15hp, 20hp, and 40hp? - correct answer️️241.2 Refer to the figure above. Calculate the minimum ampacity for a feeder serving the following 460V motor: 10hp, 20hp, and 30hp. - correct answer️️91A Refer to the figure above. What is the total load a feeder serving four 2hp motors, three 5hp motors, one 15hp motor, and one 25 hp motor? All motors are 208V. - correct answer️️219.8 A NEC Section ——————-permits an alternative method for calculating loads in multi-family dwelling. - correct answer️️220.84 The smallest size locking and grounding type receptacle that may be used to provide shore power for boats is - correct answer️️30A

Show more Read less
Institution
Load Calculation Feeders And Services Level 4
Course
Load calculation Feeders and services Level 4








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Load calculation Feeders and services Level 4
Course
Load calculation Feeders and services Level 4

Document information

Uploaded on
January 29, 2025
Number of pages
4
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

STUDYSAGE

Load calculation Feeders and
services Level 4 Module 1 exam
2025 with 100% correct answers
What is the demand factor allowed by the NEC® for calculating the neutral
conductor size for electric range load? - correct answer✔️✔️70%


Using the VA/linear foot method, the total VA that must be used in a service
calculation for a 50' show window is - correct answer✔️✔️12,500VA


Before it is considered a continuous load, a load must operate for at least how
many hours without interruption? - correct answer✔️✔️3


Which of the following factors does not affect conductor ampacity adjustments?
- correct answer✔️✔️Number of phase


If a continuous connected load totals 120A, what is the minimum current-
carrying capacity required for the feeder? - correct answer✔️✔️150A


What is the load center length for a tapped feeder with loads of 120A at 50',
110A at 60', 75A at 90', and 70A at 150'? - correct answer✔️✔️79.60


Which of the following lighting loads would be used in a residence that is 1,650
sq ft? - correct answer✔️✔️4,950VA


What is the load for 40 non-dwelling unit receptacles? (Assume that the load is
not continuous.) - correct answer✔️✔️7,200VA


The minimum service rating for a residential service is - correct
answer✔️✔️100A
1
$11.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
STUDYSAGE

Get to know the seller

Seller avatar
STUDYSAGE Yale University
View profile
Follow You need to be logged in order to follow users or courses
Sold
3
Member since
1 year
Number of followers
0
Documents
1049
Last sold
6 months ago
SELLING NOTES ONLINE,,GET ALL YOUR STUDY MATERIALS,QUALITY DOCUMENTS FOR BETTER RESULTS

Welcome to my online store, where I offer a variety of high-quality study documents designed to help students excel in their studies. Whether you need notes, summaries, or exam preparation materials, you'll find resources tailored to different subjects and learning styles. My goal is to support your academic journey by providing accessible and effective study aids." offer a variety of high-quality study documents designed to help students excel in their studies. Whether you need notes, summaries, or exam preparation materials, you'll find resources tailored to different subjects and learning styles. My goal is to support your academic journey by providing accessible and effective study aids."

Read more Read less
0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions