100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Test Bank for MWS Latest Update 2025 Questions fully Solved

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
26-01-2025
Written in
2024/2025

Test Bank for MWS Latest Update 2025 Questions fully Solved Identify TWO correct statements about conducting a daily inspection of an MWS apparatus equipped with a fire pump? - Answers Confirm that the foam tank level is full. Operate the pump drive control When conducting a service test using a static water source, you must have____feet of hard suction hose for drafting. - Answers 20 Testing the discharge pressure gauge begins by: - Answers Disconnecting all preconnected hoselines and screwing all caps onto their discharges. It is recommended that fuel, oil and mileage records be updated? - Answers as determined by the jurisdiction When entering an intersection, you should? - Answers Make eye contact with the other drivers at or entering the intersection. When driving through intersections requiring a stop, you must perform all of the following steps EXCEPT: - Answers turn on the flashers to indicate you are crossing Identify the FOUR steps for passing through a straight section of a road or highway? - Answers Maintain apparatus speed Check the side streets or roads Check for oncoming traffic Check the side and rear view mirrors All of the following statements about driving an MWS apparatus through areas of restricted horizontal and vertical clearances are true EXCEPT? - Answers use the appropriate turn signal Identify THREE things you should do when turning an MWS apparatus 180? - Answers Be aware of any obstructions in your line of travel. Use the side view mirrors equipped on the MWS apparatus. Make sure you can see your spotter. Identify TWO correct statements about looping mains in a distribution grid? - Answers They ensure that the water flows from two directions into hydrants They create constant flow and less sediment forms in the pipes. Traditional strainer - Answers Must have at least 24 inches of water above this type of strainer or the water above the strainer or the water above the strainer will whirlpool. Floating strainer - Answers May get around the 24 inch minimum depth with this type of strainer but the filter can only draw water from the bottom. low-level strainer - Answers Can rest on the bottom of a pool or tank with a minimum of two inches of water above to prevent whirlpool. If water is flowing through 200 of 5 inch hose at 300 gpm then the theoretical friction loss is approximately: - Answers 1.44 If the total pressure loss is 15 psi, what is the required pump discharge pressure for resupplying an ARFF vehicle? - Answers 35 PSI All of the following factors must be included when determining the total pressure loss TPL EXCEPT: - Answers Pump pressure loss Using the hand method, the estimated friction loss for 300 feet of 2 1/2 inch hose flowing 200 gpm is approximately? - Answers 24 PSI large diameter hoses are generally defined as hoses with a diameter between? - Answers 4 and 6 inches One characteristic of discharge pressure relief valves is they? - Answers are slow to close after being opened According to NFPA 1901, a discharge pressure relief valve must operate within: - Answers 10 seconds after discharge pressure rises 30 psi above set level. When a centrifugal pump operates? - Answers As flow increases, discharge pressure decreases; as impeller speed increases, discharge pressure increases. Place steps for pumping from an MWS apparatus internal tank to an attack apparatus or a nurse tanker once the MWS apparatus has been positioned in correct order. - Answers 1. Deploy and connect a supply line 2. Make pump operational. 3. Open tank to pump valve. 4. Prime pump if necessary 5. Open the discharge valve slowly. 6. Set the throttle to the required engine pressure. 7. Set the pressure relief valve or governor. 8. Monitor gauges associated with pump operation and make decisions based on your departments SOPs and experience. NFPA 1901 requires that an MWS apparatus that uses medium diameter hose supply lines for filling should have at least__________ external fill connections piped directly to the tank. - Answers One When a fire scene is located down a narrow lane it is best to locate the dump site? - Answers at the intersection where the lane meets a thoroughfare Identify FOUR true statements about gravity dump systems? - Answers a. Gravity dumps usually employ 8 inch or larger round or square piping with a val

Show more Read less
Institution
MWS
Course
MWS









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
MWS
Course
MWS

Document information

Uploaded on
January 26, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Test Bank for MWS Latest Update 2025 Questions fully Solved

Identify TWO correct statements about conducting a daily inspection of an MWS apparatus equipped
with a fire pump? - Answers Confirm that the foam tank level is full.



Operate the pump drive control

When conducting a service test using a static water source, you must have____feet of hard suction hose
for drafting. - Answers 20

Testing the discharge pressure gauge begins by: - Answers Disconnecting all preconnected hoselines and
screwing all caps onto their discharges.

It is recommended that fuel, oil and mileage records be updated? - Answers as determined by the
jurisdiction

When entering an intersection, you should? - Answers Make eye contact with the other drivers at or
entering the intersection.

When driving through intersections requiring a stop, you must perform all of the following steps
EXCEPT: - Answers turn on the flashers to indicate you are crossing

Identify the FOUR steps for passing through a straight section of a road or highway? - Answers Maintain
apparatus speed

Check the side streets or roads

Check for oncoming traffic

Check the side and rear view mirrors

All of the following statements about driving an MWS apparatus through areas of restricted horizontal
and vertical clearances are true EXCEPT? - Answers use the appropriate turn signal

Identify THREE things you should do when turning an MWS apparatus 180? - Answers Be aware of any
obstructions in your line of travel.



Use the side view mirrors equipped on the MWS apparatus.



Make sure you can see your spotter.

, Identify TWO correct statements about looping mains in a distribution grid? - Answers They ensure that
the water flows from two directions into hydrants



They create constant flow and less sediment forms in the pipes.

Traditional strainer - Answers Must have at least 24 inches of water above this type of strainer or the
water above the strainer or the water above the strainer will whirlpool.

Floating strainer - Answers May get around the 24 inch minimum depth with this type of strainer but the
filter can only draw water from the bottom.

low-level strainer - Answers Can rest on the bottom of a pool or tank with a minimum of two inches of
water above to prevent whirlpool.

If water is flowing through 200 of 5 inch hose at 300 gpm then the theoretical friction loss is
approximately: - Answers 1.44

If the total pressure loss is 15 psi, what is the required pump discharge pressure for resupplying an ARFF
vehicle? - Answers 35 PSI

All of the following factors must be included when determining the total pressure loss TPL EXCEPT: -
Answers Pump pressure loss

Using the hand method, the estimated friction loss for 300 feet of 2 1/2 inch hose flowing 200 gpm is
approximately? - Answers 24 PSI

large diameter hoses are generally defined as hoses with a diameter between? - Answers 4 and 6 inches

One characteristic of discharge pressure relief valves is they? - Answers are slow to close after being
opened

According to NFPA 1901, a discharge pressure relief valve must operate within: - Answers 10 seconds
after discharge pressure rises 30 psi above set level.

When a centrifugal pump operates? - Answers As flow increases, discharge pressure decreases; as
impeller speed increases, discharge pressure increases.

Place steps for pumping from an MWS apparatus internal tank to an attack apparatus or a nurse tanker
once the MWS apparatus has been positioned in correct order. - Answers 1. Deploy and connect a
supply line

2. Make pump operational.

3. Open tank to pump valve.

4. Prime pump if necessary

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
361
Member since
1 year
Number of followers
16
Documents
29367
Last sold
1 day ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.5

57 reviews

5
19
4
15
3
12
2
0
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions