RHODE ISLAND Journeyman/Master Plumber
Exam| Questions Solved 100% Correct | Verified
Answers
Plumbing Code Regulation SBC-3 - ANSWER State of Rhode Island Plumbing Code is
known as:
4' 6" Below Grade - ANSWER Water Services Shall Be Installed Not Less Than:
Insulated/Heated or Both - ANSWER Piping installed in exterior walls or areas subject to
freezing must:
36" Below Grade - ANSWER Building Sewers connected to a public sewer shall have a
minimum coverage of:
Under a water heater 6 gallons or greater that is elevated - ANSWER A safe waste pan
shall be installed
2" deep with 2" clearance around heater - ANSWER A safe waste pan shall be at least
10' undisturbed compacted earth - ANSWER Water service piping and building
drain/sewer shall be separated by:
Water line is installed minimum 12" above sewer line at highest point - ANSWER Water
service separation distance is not required if:
50' - ANSWER Distance for a septic tank/sewer to a private water supply(well) is:
, 6"below the roof with an approved fitting - ANSWER Where frost closure is common an
increase in vent size shall take place:
"V" zone (subject to wave heights in excess of 3') - ANSWER High Hazard flood zone is:
8.0% Lead - ANSWER Lead free pipe and fittings contain less than:
110 degrees - ANSWER Hot water is water at temperature greater than or equal to:
0.2% Lead - ANSWER Lead free solder and flux contain no more than
0.5 inches - ANSWER Strainer plates on drain lines for rodent proofing must have
openings:
Two pipe size greater than the pipe passing through it - ANSWER Sleeves for pipes
passing through foundation walls or under footings shall be:
500' - ANSWER Travel distance to toilet facilities in merchantile/occupancies are:
300' - ANSWER Travel distance to toilet facilities in covered malls are:
15" - ANSWER Water closets, bidets or lavatories shall have a clearance from center of
fixture to wall of:
21" - ANSWER The required clearance from front of fixture to a wall, door or other
fixture is:
Exam| Questions Solved 100% Correct | Verified
Answers
Plumbing Code Regulation SBC-3 - ANSWER State of Rhode Island Plumbing Code is
known as:
4' 6" Below Grade - ANSWER Water Services Shall Be Installed Not Less Than:
Insulated/Heated or Both - ANSWER Piping installed in exterior walls or areas subject to
freezing must:
36" Below Grade - ANSWER Building Sewers connected to a public sewer shall have a
minimum coverage of:
Under a water heater 6 gallons or greater that is elevated - ANSWER A safe waste pan
shall be installed
2" deep with 2" clearance around heater - ANSWER A safe waste pan shall be at least
10' undisturbed compacted earth - ANSWER Water service piping and building
drain/sewer shall be separated by:
Water line is installed minimum 12" above sewer line at highest point - ANSWER Water
service separation distance is not required if:
50' - ANSWER Distance for a septic tank/sewer to a private water supply(well) is:
, 6"below the roof with an approved fitting - ANSWER Where frost closure is common an
increase in vent size shall take place:
"V" zone (subject to wave heights in excess of 3') - ANSWER High Hazard flood zone is:
8.0% Lead - ANSWER Lead free pipe and fittings contain less than:
110 degrees - ANSWER Hot water is water at temperature greater than or equal to:
0.2% Lead - ANSWER Lead free solder and flux contain no more than
0.5 inches - ANSWER Strainer plates on drain lines for rodent proofing must have
openings:
Two pipe size greater than the pipe passing through it - ANSWER Sleeves for pipes
passing through foundation walls or under footings shall be:
500' - ANSWER Travel distance to toilet facilities in merchantile/occupancies are:
300' - ANSWER Travel distance to toilet facilities in covered malls are:
15" - ANSWER Water closets, bidets or lavatories shall have a clearance from center of
fixture to wall of:
21" - ANSWER The required clearance from front of fixture to a wall, door or other
fixture is: