FLS Director's Quiz (Fire and Non-Fire Questions) Questions and Answers 100% Pass 1) Who is responsible to report to the Fire Command Station in the absence of a FLSD or a Deputy FLSD in an office building after normal business hours? a) floor warden b) Chief Engineer c) Building Evacuation Supervisor d) Fire Brigade member - C 2) If a building is equipped with a stand pipe only, what color would the buildings fire department connection be? a) red b) green c) yellow d) silver - A 3) How many floor wardens are required in a 30 story Class B building? a) one b) 30 c) 60 d) depends on the square footage of each floor - B 4) Which of the following initiating devices must be replaced after it has activated? a) rate of rise heat detector b) single action pull station c) carbon monoxide detector d) fixed temperature heat detector - D 2Katelyn Whitman, All Rights Reserved © 2025 5) A technician enters your building to work on your buildings multi zone standpipe system, as FLSD you should ensure the technician possesses what certification? (Reference Material) a) S-97 b) w-96 c) S-11 d) S-14 - D 6) Water dripping from an automatic ball drip, after the FDNY has disconnected from the FDNY connection, is an indication of___________? a) a defect in the FDNY Connection b) some leakage from this valve is expected c) indicates a faulty lower check valve d) indicates the system was overcharged - B 7) All of the following are signals received at the Fire Alarm Control Panel except? a) alarm signal b) trouble signal c) surge signal d) supervisory signal - C 8) Which of the following will not cause a recall of a buildings elevators? a) smoke detector in the elevator lobby b) sprinkler activation c) smoke detector in elevator machinery room d) manual pull station - D 9) Under the 2014 building code, buildings that are used primarily for transacting business and rendering professional services would be classified as____? a) class J b) class R-1 c) Class A d) Class B - D 10) Which of the following is not an action to be taken during a fire or non fire emergency? 3Katelyn Whitman, All Rights Reserved © 2025 a) shelter in place b) in building relocation c) partial evacuation d) Roof relocation - D 11) If a building has 200 sprinkler heads in it's sprinkler system, how many spare heads must be kept on the premises? (Reference Material) a) 6 b) 12 c) 24 d) 10 - A 12) All of the following are members of the Fire and Life Safety Staff except? a) Critical operations staff b) Deputy Fire and Life Safety Director c) Deputy Floor Warden d) owners representative - D 13) If a buildings auxiliary radio communication system is out of service, a tag identifying the system as out if service must be placed at? a) the entrance to the building b) at all warden phone locations c) at the Fire command center d) at the buildings communications center - C 4Katelyn Whitman, All Rights Reserved © 2025 14) Which of the following pumps is designed to operate when there is a slight drop in pressure due to leakage or a pressure surge? a) Fire Pump b) booster pump c) special service pump d) Jockey Pump - D 15) The vertical portion of the system piping that delivers the water supply for hose connections and sprinklers on standalone as well as combined systems is known as: a) cross main b) branch line c) riser d) feed main - C 16) The Fire Department recommends that the FLS staff participate in training designed to familiarize them with their duties. The initial training in both fire and non-fire training the training duration for FLS brigade members should be (Both Parts):(Reference Material) a) two hours b) three hours c) one hour d) thirty minutes - B 17) Which of the following would result in the shutting down of a buildings HVAC system? a) manual pull station b) rate of rise heat detector c) duct smoke detector d) area smoke detector - C

Show more Read less
Institution
FLS
Course
FLS











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FLS
Course
FLS

Document information

Uploaded on
January 19, 2025
Number of pages
46
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

FLS Director's Quiz (Fire and Non-Fire
Questions) Questions and Answers
100% Pass

1) Who is responsible to report to the Fire Command Station in the absence of a FLSD

or a Deputy FLSD in an office building after normal business hours?


a) floor warden b) Chief Engineer c) Building Evacuation Supervisor d) Fire Brigade

member - ✔✔C


2) If a building is equipped with a stand pipe only, what color would the buildings fire

department connection be?


a) red b) green c) yellow d) silver - ✔✔A


3) How many floor wardens are required in a 30 story Class B building?


a) one b) 30 c) 60 d) depends on the square footage of each floor - ✔✔B


4) Which of the following initiating devices must be replaced after it has activated?


a) rate of rise heat detector b) single action pull station c) carbon monoxide detector d)

fixed temperature heat detector - ✔✔D




Katelyn Whitman, All Rights Reserved © 2025 1

,5) A technician enters your building to work on your buildings multi zone standpipe

system, as FLSD you should ensure the technician possesses what certification?

(Reference Material)


a) S-97 b) w-96 c) S-11 d) S-14 - ✔✔D


6) Water dripping from an automatic ball drip, after the FDNY has disconnected from

the FDNY connection, is an indication of___________?


a) a defect in the FDNY Connection b) some leakage from this valve is expected c)

indicates a faulty lower check valve d) indicates the system was overcharged - ✔✔B


7) All of the following are signals received at the Fire Alarm Control Panel except?


a) alarm signal b) trouble signal c) surge signal d) supervisory signal - ✔✔C


8) Which of the following will not cause a recall of a buildings elevators?


a) smoke detector in the elevator lobby b) sprinkler activation c) smoke detector in

elevator machinery room d) manual pull station - ✔✔D


9) Under the 2014 building code, buildings that are used primarily for transacting

business and rendering professional services would be classified as____?


a) class J b) class R-1 c) Class A d) Class B - ✔✔D


10) Which of the following is not an action to be taken during a fire or non fire

emergency?



Katelyn Whitman, All Rights Reserved © 2025 2

,a) shelter in place b) in building relocation c) partial evacuation d) Roof relocation -

✔✔D


11) If a building has 200 sprinkler heads in it's sprinkler system, how many spare heads

must be kept on the premises? (Reference Material)


a) 6 b) 12 c) 24 d) 10 - ✔✔A


12) All of the following are members of the Fire and Life Safety Staff except?


a) Critical operations staff


b) Deputy Fire and Life Safety Director


c) Deputy Floor Warden


d) owners representative - ✔✔D


13) If a buildings auxiliary radio communication system is out of service, a tag

identifying the system as out if service must be placed at?


a) the entrance to the building


b) at all warden phone locations


c) at the Fire command center


d) at the buildings communications center - ✔✔C




Katelyn Whitman, All Rights Reserved © 2025 3

, 14) Which of the following pumps is designed to operate when there is a slight drop in

pressure due to leakage or a pressure surge?


a) Fire Pump b) booster pump c) special service pump d) Jockey Pump - ✔✔D


15) The vertical portion of the system piping that delivers the water supply for hose

connections and sprinklers on standalone as well as combined systems is known as:


a) cross main b) branch line c) riser d) feed main - ✔✔C


16) The Fire Department recommends that the FLS staff participate in training designed

to familiarize them with their duties. The initial training in both fire and non-fire

training the training duration for FLS brigade members should be (Both

Parts):(Reference Material)


a) two hours b) three hours c) one hour d) thirty minutes - ✔✔B


17) Which of the following would result in the shutting down of a buildings HVAC

system?


a) manual pull station b) rate of rise heat detector c) duct smoke detector d) area smoke

detector - ✔✔C


18) If the stem on an os&y valve is raised, this indicates a stanpipe system is?


a) on b) out of service c) off d) defective - ✔✔A


19) The Temperature in the fire pump room should be kept at a minimum of:



Katelyn Whitman, All Rights Reserved © 2025 4

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1093
Member since
2 year
Number of followers
482
Documents
33021
Last sold
1 day ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions