MA 2ND FIREMAN EXAM/NEWEST 2025 WITH COMPLETE QUESTIONS AND CORRECT VERIFIED ANSWERS/ WELL GRADED A+// LATEST VERSION What is steam bound in relation to pumps? And what is air bound? And how do you correct these situations? - CORRECT ANSWERS-Steam bound is when the water flashes to steam at the inlet of the pump causing cavitation cool the water coming into the pump to correct the situation Air bound is when air is trapped in the pump causing pump malfunctioning to correct the situation fill the pump with water and let the air out through the vent How do you blow soot on the boiler? List all precautionary steps taken. - CORRECT ANSWERS-Using soot blowers, check connectivity and operation, make sure path is clear of obstruction or leakage, soot blowing should be done with the air on manual at maximum level and the boiler load over 50% According to Chapter 146 of the Massachusetts General Law, what can you do with a second class fireman license? - CORRECT ANSWERS-Operate any boiler or boilers under the engineer or fireman in direct charge there of. How do you take over a shift? - CORRECT ANSWERS-Talk to the operator you are relieving, read the log, make a round and do safety checks check water level How often do boilers require inspection? - CORRECT ANSWERS-Internal and external inspection of the boiler is required by Law once a year Who will inspect your boiler? - CORRECT ANSWERS-an insurance company approved by the state or a state inspector. first inspection is done by the state inspector. How often do air tanks need to be inspected? What size tanks? - CORRECT ANSWERS-air tanks holding one cubic foot of air and have a diameter greater than 6" operating over pressure of 50 psi require inspection every other year. Where do you keep your license? - CORRECT ANSWERS-Posted in view/boiler room In relation to boiler attendance, define continuous, non-continuous and periodic attendance. - CORRECT ANSWERS-Periodic inspection: between 9-250 HP must be in the same building, check on the boiler on a periodic basis. Non-continuous between 251 and 500 hp check on the boiler 4 to 6 times per shift, remote monitoring required. Continuous attendance over 500 hp manned all the times

Show more Read less
Institution
MA 2ND FIREMAN EX
Course
MA 2ND FIREMAN EX










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
MA 2ND FIREMAN EX
Course
MA 2ND FIREMAN EX

Document information

Uploaded on
January 12, 2025
Number of pages
27
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

MA 2ND FIREMAN EXAM/NEWEST 2025 WITH
COMPLETE QUESTIONS AND CORRECT VERIFIED
ANSWERS/ WELL GRADED A+// LATEST VERSION

What is steam bound in relation to pumps? And what is air bound? And how do you
correct these situations? - CORRECT ANSWERS-Steam bound is when the water
flashes to steam at the inlet of the pump causing cavitation cool the water coming into
the pump to correct the situation
Air bound is when air is trapped in the pump causing pump malfunctioning
to correct the situation fill the pump with water and let the air out through the vent

How do you blow soot on the boiler? List all precautionary steps taken. - CORRECT
ANSWERS-Using soot blowers, check connectivity and operation, make sure path is
clear of obstruction or leakage, soot blowing should be done with the air on manual at
maximum level and the boiler load over 50%

According to Chapter 146 of the Massachusetts General Law, what can you do with a
second class fireman license? - CORRECT ANSWERS-Operate any boiler or boilers
under the engineer or fireman in direct charge there of.

How do you take over a shift? - CORRECT ANSWERS-Talk to the operator you are
relieving, read the log, make a round and do safety
checks check water level

How often do boilers require inspection? - CORRECT ANSWERS-Internal and external
inspection of the boiler is required by Law once a year

Who will inspect your boiler? - CORRECT ANSWERS-an insurance company approved
by the state or a state inspector. first inspection is
done by the state inspector.

How often do air tanks need to be inspected? What size
tanks? - CORRECT ANSWERS-air tanks holding one cubic foot of air and have a
diameter greater than 6"
operating over pressure of 50 psi require inspection every other year.

Where do you keep your license? - CORRECT ANSWERS-Posted in view/boiler room

In relation to boiler attendance, define continuous, non-continuous and periodic
attendance. - CORRECT ANSWERS-Periodic inspection: between 9-250 HP must be in
the same building,
check on the boiler on a periodic basis. Non-continuous between 251 and 500 hp
check on the boiler 4 to 6 times per shift, remote monitoring required. Continuous
attendance over 500 hp manned all the times

,How many low water cut outs are required by the state code? - CORRECT ANSWERS-
two, the one set
lower requires a manual reset.

How many pressure limit switches are required by the State code? - CORRECT
ANSWERS-two the one
set higher require a manual reset.

British Thermal Unit (BTU) is - CORRECT ANSWERS-The amount of heat required to
raise one pound of water one degree Fahrenheit

Safety valve should be tested by hand at which pressure - CORRECT ANSWERS-75%
of working load

A siphon protects the steam gauge from - CORRECT ANSWERS-High temperature of
steam

Who is authorized to repair and adjust safety valves - CORRECT ANSWERS-
manufacturer's representative

A drum vent should be closed when the boiler pressure increases to - CORRECT
ANSWERS-25 PSI

Periodic attendance covers boiler horsepower from - CORRECT ANSWERS-9-250 BHP

The Ringleman scale is associated with - CORRECT ANSWERS-Smoke density

Steam traps are used to - CORRECT ANSWERS-Remove air and water from
steamlines

Excess air is - CORRECT ANSWERS-Air supplied to the combustion process that is
more than the theoretical amount required

What is viscosity - CORRECT ANSWERS-Internal resistance to fuel oil flow

Lowest temperature that oil will flow is it's - CORRECT ANSWERS-Pour point

Oxygen in boiler water will cause - CORRECT ANSWERS-Pitting

Frequency of boiler blowdown is best determined by - CORRECT ANSWERS-Daily
testing of boiler water

Burning pulverized coal requires how much excess air - CORRECT ANSWERS-30%

, What is the difference between a rotary pump and centrifugal pump - CORRECT
ANSWERS-Rotary is positive displacement, centrifugal is not

In reference to a duplex pump, what do 3x2x6 represent - CORRECT ANSWERS-
Diameter of steam piston, diameter of fluid piston and length of stroke

A centrifugal pump should be started with the discharge valve - CORRECT ANSWERS-
Closed

Which steam trap has no moving parts? - CORRECT ANSWERS-None of the above

Two types of air pre heaters are - CORRECT ANSWERS-Tubular and regenerative

Two blowdown valves are required in boilers operating - CORRECT ANSWERS-At 100
PSI and over

How many BTU's are required to raise 25 lbs of water 15 degrees Fahrenheit -
CORRECT ANSWERS-375 BTU's

How much notice is required for an internal boiler inspection - CORRECT ANSWERS-
14 days

Two types of soot blowers are - CORRECT ANSWERS-Stationary and retractable

A non return valve allows steam to flow - CORRECT ANSWERS-Out of the boiler only

Baffles are used to - CORRECT ANSWERS-Direct flue gas through the boiler

10" of HG is equivalent to_____PSIA - CORRECT ANSWERS-4.91

One BTU is equivalent to______ft/lbs of work - CORRECT ANSWERS-778

The circumference of a fire tube 4" in diameter is - CORRECT ANSWERS-12.56 inches

If the safety valve is removed for a hydrostatic test a_____should be installed -
CORRECT ANSWERS-Blank/blind flange

Specific volume is expressed as - CORRECT ANSWERS-Ft³ per pound

Latent heat is - CORRECT ANSWERS-Heat added to a substance that causes a
change of state

A check valve is required between the - CORRECT ANSWERS-Feed pump and boiler

Boiler heating surface is defined as the parts of the boiler with - CORRECT ANSWERS-
Water on one side and products of combustion in the other
$17.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
gideonngari

Get to know the seller

Seller avatar
gideonngari Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
6
Member since
1 year
Number of followers
0
Documents
794
Last sold
1 week ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions