fire department connection - Correct Ans-normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. system control valve - Correct Ans-valve controlling flow to water-based fire protection systems. fire command center - Correct Ans-... MFSPC - Correct Ans-... MLP - Correct Ans-... tags - Correct Ans-on closed section valves serving affected areas: area affected, brief description, occupancy classification, c of f number, estimated time until operational Green tag - Correct Ans-no impairment found in entire system- main control valve white tag - Correct Ans-fully out of service- place on all fire department connecitons red tag - Correct Ans-place on main control valve if FULLY OR PARTIALLY out of service... put sprinkler company name, date of removal from service and anticipated time to operational blue disk - Correct Ans-partially out of service- on all fire department connections water storage tank - Correct Ans-... OS & Y valve - Correct Ans-indicating type of control valve used for fire sprinkler system deluge valve - Correct Ans-water supply control valve intended to be operated by actuation of an automatic detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO deluge sprinkler system - Correct Ans-employing open sprinklers that are attached to a piping system that is connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and discharges from all sprinklers attached. Early suppresion fast response sprinklers - Correct Ans-fast response sprinkler that is listed for its capability to provide fire suppression of specific high challenge fire hazards extra large orifice sprinklers - Correct Ans-= or > 1 inch less pressure to achieve a given discharge density extended coverage sprinkler - Correct Ans-400 max square feet discharge fire pump - Correct Ans-a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected to public water source or tank. provides higher pressure to sprinkler system Glass bulb sprinkler - Correct Ans-operated by heat breaking a glass bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for standard response hose valve - Correct Ans-valve to additional hose connection hydraulic placard - Correct Ans-sign attached to a hydraulically calculated sprinkler system indicating the design density, required gallons per minute and pressure for the system to operate properly hydraulically calculated systems - Correct Ans-method of sizing auto sprinkler piping using a prescribed amount of water to be distributed over a specific area. impairment coordinator - Correct Ans-in charge of safety during out of service systems intermediate level sprinkler - Correct Ans-sprinkler equipped with integral shields to protect the operating elemtn form discharge from sprinklers installed at higher elevations large orifice sprinkler - Correct Ans-sprinkler head with orifice size equal or greater than 3/4 and less than 1 inch listed device - Correct Ans-A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common. Master Pressure Reducing Valve - Correct Ans-A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain - Correct Ans-The primary drain connection located on the system riser and also utilized as a flow test connection. Microbiologically Influenced Corrosion (MIC) - Correct Ans-Corrosion caused by the presence of microbes in the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and blockages.

Show more Read less
Institution
S12 Sprinkler
Course
S12 sprinkler









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
S12 sprinkler
Course
S12 sprinkler

Document information

Uploaded on
January 9, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

S12 sprinkler test



S12 sprinkler test study questions and
answers top rated 2025
fire department connection - Correct Ans-normally on exterior of building... FDNY can
pump supplemental water into the sprinkler system, standpipe, or other system
furnishing water for fire extinguishment to supplement existing water supplies.

system control valve - Correct Ans-valve controlling flow to water-based fire protection
systems.

fire command center - Correct Ans-...

MFSPC - Correct Ans-...

MLP - Correct Ans-...

tags - Correct Ans-on closed section valves serving affected areas: area affected, brief
description, occupancy classification, c of f number, estimated time until operational

Green tag - Correct Ans-no impairment found in entire system- main control valve

white tag - Correct Ans-fully out of service- place on all fire department connecitons

red tag - Correct Ans-place on main control valve if FULLY OR PARTIALLY out of
service... put sprinkler company name, date of removal from service and anticipated
time to operational

blue disk - Correct Ans-partially out of service- on all fire department connections

water storage tank - Correct Ans-...

OS & Y valve - Correct Ans-indicating type of control valve used for fire sprinkler system

deluge valve - Correct Ans-water supply control valve intended to be operated by
actuation of an automatic detection system that is installed in the same area as the
discharge devices. INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system - Correct Ans-employing open sprinklers that are attached to a
piping system that is connected to a water supply through a valve that is opened by the
operation of a detection system installed in the same areas as the sprinklers. WHEN IT
OPENS, water flows into the piping system and discharges from all sprinklers attached.

Early suppresion fast response sprinklers - Correct Ans-fast response sprinkler that is
listed for its capability to provide fire suppression of specific high challenge fire hazards



S12 sprinkler test

, S12 sprinkler test



extra large orifice sprinklers - Correct Ans-= or > 1 inch less pressure to achieve a given
discharge density

extended coverage sprinkler - Correct Ans-400 max square feet discharge

fire pump - Correct Ans-a provider of liquid flow and pressure dedicated to fire
protection. A fire pump is a part of a fire sprinklers system water supply and can be
powered by electric, diesel or steam. connected to public water source or tank. provides
higher pressure to sprinkler system

Glass bulb sprinkler - Correct Ans-operated by heat breaking a glass bulb filled with a
non freezing liquid with diameters that vary form 3 mm for quick response to 5 mm for
standard response

hose valve - Correct Ans-valve to additional hose connection

hydraulic placard - Correct Ans-sign attached to a hydraulically calculated sprinkler
system indicating the design density, required gallons per minute and pressure for the
system to operate properly

hydraulically calculated systems - Correct Ans-method of sizing auto sprinkler piping
using a prescribed amount of water to be distributed over a specific area.

impairment coordinator - Correct Ans-in charge of safety during out of service systems

intermediate level sprinkler - Correct Ans-sprinkler equipped with integral shields to
protect the operating elemtn form discharge from sprinklers installed at higher
elevations

large orifice sprinkler - Correct Ans-sprinkler head with orifice size equal or greater than
3/4 and less than 1 inch

listed device - Correct Ans-A fire protection component that has been tested to perform
under parameters specified for its use by a nationally recognized testing agency.
Underwriter's Laboratory (UL) and Factory Mutual (FM) are the two most common.

Master Pressure Reducing Valve - Correct Ans-A pressure reducing valve installed to
regulate pressures in an entire fire protection system and/or standpipe system zone.

Main Drain - Correct Ans-The primary drain connection located on the system riser and
also utilized as a flow test connection.

Microbiologically Influenced Corrosion (MIC) - Correct Ans-Corrosion caused by the
presence of microbes in the water supply that over time attack the interior of metallic
piping and cause leaks, pitting, and blockages.



S12 sprinkler test

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Bestzone Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
181
Member since
4 year
Number of followers
111
Documents
5004
Last sold
1 month ago
STUDY EXAMS AND STUDY GUIDES SUMMARIES ESSAY ALL VERIFIED

WELCOME!!!

3.9

27 reviews

5
13
4
4
3
6
2
2
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions