100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

HVAC NATE Heat Pump Exam Questions & Answers Latest Update.

Rating
-
Sold
-
Pages
20
Grade
A+
Uploaded on
03-01-2025
Written in
2024/2025

HVAC NATE Heat Pump Exam Questions & Answers Latest Update.

Institution
HVAC NATE Heat Pump
Course
HVAC NATE Heat Pump










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
HVAC NATE Heat Pump
Course
HVAC NATE Heat Pump

Document information

Uploaded on
January 3, 2025
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

HVAC NATE Heat Pump Exam Questions & Answers Latest Update



HVAC NATE Heat Pump Exam Questions
& Answers Latest Update.
On an R-22 system, line diameters and lengths are typically specified for a vapor pressure drop that
does not exceed what? - ✔✔✔ - 6-7PSI or 6F



What is the primary purpose of using flux when soldering copper or brass parts? - ✔✔✔ - Prevent
Oxidation



The water that results from a defrost cycle of an air to air heat pump(runoff) must? - ✔✔✔ - Drain off
and away from the outdoor coil.



Why must the runoff be drained off and away from the outdoor coil? - ✔✔✔ - Excessive ice can build
up on the bottom of the coil and can reduce capacity.



What is the component that reduces sound transmission and prevents water leaks of a package heat
pump installed on a roof? - ✔✔✔ - Curb Gasket



Why do you need to add a control for a heat pump indoor coil that is installed on a fossil fuel furnace? -
✔✔✔ - So the heat pump and furnace do not operate at the same time in normal heating.



What happens when you energize a hermetic refrigeration compressor and the system is in a deep
vacuum? - ✔✔✔ - Motor windings could become damaged.



What needs to happen in order to consider an evacuation to be complete? - ✔✔✔ - System should be
evacuated to a vacuum of 500 Microns or below.



A system is supplied from the factory with charge for a 15 foot line set. The data plate shows the
required system charge to be 5 pounds 10 ounces. The line set uses a 3/8 inch liquid line and is 25 feet
long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigerant to be added for each

©®™ Page 1

,HVAC NATE Heat Pump Exam Questions & Answers Latest Update


added foot of refrigerant line length. How much refrigerant is needed to completely charge the
system? - ✔✔✔ - 6lbs



Where are drive slips typically installed? - ✔✔✔ - On the shorter sides of rectangular duct.



What is a necessary check to properly set a heat anticipator? - ✔✔✔ - Heating control circuit amperage

draw.



A heat pump operating in normal ice free conditions maintains a certain temperature difference
between the outdoor coil temperature and the surrounding outdoor ambient. What is this
temperature referred to as? - ✔✔✔ - Coil TD.



What is the smallest refrigerant leak that an electronic leak detector should be capable of sensing? -
✔✔✔ - .o5oz per year.



When checking the pressures in an operating system with a manifold gauge set, will refrigerant oil in a
hose will have an effect on the gauge? - ✔✔✔ - No



What is the absolute pressure at sea level if a gauge pressure is 35 psig? - ✔✔✔ - 49.7psia



100,000 BTUH output furnace.

Return air temp is 65F.

Supply air is 135F.

What is the CFM? - ✔✔✔ - 1323CFM



What is the best method of repair when a residential supply diffuser is noisy because of a loose vane? -
✔✔✔ - Replace the diffuser.



©®™ Page 2

, HVAC NATE Heat Pump Exam Questions & Answers Latest Update


When performing preventive maintenance on a heat pump what should the technician check and why?
- ✔✔✔ - Outdoor fan. To be certain it runs freely with no binding.



What is the effect of 170 volts supplied to a 208/230 volt compressor? - ✔✔✔ - Would cause the
current to increase and the motor may trip on overload.



On a service call for a cooling problem with a heat pump, your inspections find a liquid line that has
condensation on it. What is most likely to cause this? - ✔✔✔ - Restriction in the liquid line.



What is a reason for cool air complaints when a heat pump is operating in the heating cycle? - ✔✔✔ -
Excessive supply air velocities.



The following measurements are recorded on an operating heat pump system. The heat pump is
operating with the compressor only with no auxiliary heat:



• Heat pump only supply air temperature 92°F



• Heat pump only return air temperature 70°F



• Outdoor temperature 54°F



• Supply air temp. /auxiliary heat ON 115°F



• Return air temp. /auxiliary heat ON 70°F



• CFM 1228




©®™ Page 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Boffin Harvard University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1762
Member since
4 year
Number of followers
1469
Documents
7146
Last sold
1 day ago
Pilot Study

Prevent resits and get higher grades.

3.8

433 reviews

5
209
4
74
3
70
2
16
1
64

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions