California Fluoroscopy Test UPDATED ACTUAL Questions and CORRECT Answers An image intensifiers photocathode causes ___ to be given off in direct proportion to the intensity of the fluorescent light: a. remnant radiation b. electrons c. x-rays d. light photons - CORRECT ANSWER - electrons

Show more Read less
Institution
Fluoroscopy
Course
Fluoroscopy











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fluoroscopy
Course
Fluoroscopy

Document information

Uploaded on
December 24, 2024
Number of pages
89
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

California Fluoroscopy Test UPDATED
ACTUAL Questions and CORRECT
Answers
An image intensifiers photocathode causes ___ to be given off in direct proportion to the
intensity of the fluorescent light:
a. remnant radiation
b. electrons
c. x-rays

d. light photons - CORRECT ANSWER - electrons


What fluoroscopic television system device decodes the video signal into a visible image?
a. Vidicon camera
b. Camera control unit
c. Television monitor

d. Electron gun - CORRECT ANSWER - Television Monitor


Which of the following materials are used in the construction of a fluoroscopic tabletop?
1. Lead
2. Aluminum
3. Bakelite

4. Carbon fiber - CORRECT ANSWER - 2, 3, and 4


Geometric factors in the shape of the image intensification tube
b. Focal-film-distance (FFD)
c. Object-to-image distance (OID)

d. Minification gain - CORRECT ANSWER - ...

,If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is located:
a. either over or under the table
b. under the table
c. over the table

d. not enough information provided - CORRECT ANSWER - b. Under the table


The mottle level of an image can be adjusted by:
1. changing mA
2. changing kVp
3. changing the exposure factors

4. increasing the number of available x-ray photons - CORRECT ANSWER - All of the
above


During a fluoroscopic exam, the main source of scattered radiation is produced from:
a. the patient
b. x-ray source
c. table top

d. leakage radiation - CORRECT ANSWER - the patient


Excessive lighting in the fluoroscopy room:
a. Helps to perceive a dim image as brighter
b. Helps to properly adjust the overall luminance of the TV image
c. Enhances visualization of a black and white TV image

d. May result in increasing the technical operating factors - CORRECT ANSWER - May
result in increasing the technical operating factors


Suitable gonad shields must be used:
a. Whenever gonads are within the useful x-raybeam

,b. When shielding of gonads does not interfere with the diagnosis
c. On all potentially procreative patients

d. At all times - CORRECT ANSWER - When shielding of gonads does not interfere with
the diagnosis


Which of the following are true concerning cine film?
1. Available film sizes are: 70 mm, 100 mm, and 110 mm
2. The larger the film size the better the image quality
3. Nearly all cine-fluorography exams involve studies of the GI system
4. Delivers approximately the same dose as routine photospot image recording - CORRECT
ANSWER - 2 only


The exposure rate at the tabletop may not exceed five rads per minute except:
1. when using the ABC on large patients
2. during magnification mode

3. where higher exposure rates are allowed - CORRECT ANSWER - b. 1, 2 and 3 only


Images produced with photo spot film cameras ___ spot films taken with conventional cassettes.
1. use a higher mA than
2. require about 1/2 to 1/3 the dose of

3. exhibit superior image quality compared to - CORRECT ANSWER - require about 1/2
to 1/3 the dose


The ability of an imaging system to differentiate small objects that are closely spaced as separate
objects is referred to as:
a. Differentiation
b. Resolution
c. Statistical fluctuation

d. Detector contrast - CORRECT ANSWER - b. Resolution

, The photoconductive target in a television camera pick-up tube:
a. Conducts electrons across to the target
b. Allows a proportional electron charge to be generated at a particular position
c. Creates a video signal
d. Creates an electronic current which is converted into a video image


. - CORRECT ANSWER - Allows a proportional electron charge to be generated at a
particular position


Size distortion is primarily caused by:
a. Focal-film-distance (FFD)
b. Geometric factors in the shape of the image intensification tube
c. Minification gain

d. Object-to-image distance (OID) - CORRECT ANSWER - Object-to-image distance
(OID)


The overall luminescence of the TV image may be properly adjusted by:
1. increasing room lighting
2. adjusting the contrast control button on the TV monitor

3. adjusting the brightness control button on the TV monitor - CORRECT ANSWER -2
and 3 only


Which of the following statements is true concerning fluoroscopic grids?
a. Reduces scattered radiation produced in the image intensifier
b. The typical grid ratio is 12:1
c. High ratio grids are preferred
d. Located between the patient and input layer of the image intensifier - CORRECT
ANSWER - Located between the patient and input layer of the image intensifier

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES Stanford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1101
Member since
1 year
Number of followers
103
Documents
68972
Last sold
15 hours ago
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

176 reviews

5
75
4
31
3
47
2
8
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions