Journeyman electrician exam prep Questions and Answers 100% Pass What table sizes bonding jumpers for for AC systems? - 250.102(C)(1) The NEC defines continuous load to be a load where max current on the circuit continues for at least how many hours? - Three To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current carrying conductors in a raceway? - Greater than three Where in the NEC codebook would you find EMT sizes for a given size and number of conductors? - Annex C, Table C.1 Section 210.20(A) states that the over current protection for branch circuits including continuous loads must be greater than 100% of the noncontinuous plus ____ of the continuous load. - 125% Liquidtight Flexible Metal Conduit shall be fastened within of each box or other conduit termination - Twelve inches 314.28(A)(1) states that straight pulls in pull boxes with conductors size 4 AWG or larger, box length should be greater than or equal to times the trade diameter of the largest conduit entering box. - Eight Chapter 9 note 4 states conduit nipples less than 24 inches can fill to a max of their cross sectional area - 60 percent Table 348.22 gives the max number of insulated conductors in size _______ FMC? - 3/8 (trade size) 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE Guest rooms of hotels, motels, & sleeping rooms in dorms need a MIN or _____ general purpose receptacles installed that are readily accessible? - Two When branch-circuit conductors are contained inside a ballast compartment and they are within 3 inches of the ballast, the conductors shall have a temperature rating of at LEAST _____. a) 105 degrees C b) 90 degrees C c) 75 degrees C d) 60 degrees C - B: 90 degrees C Ref: 410.68 Class _____ locations are those that are hazardous because of the presence of easily ignitible fibers or materials producing combustible flyings. a) I b) II c) III d) IV - C: III Ref: 500.5(D) Class _____ locations are those in which flammable gases, flammable liquid produced vapors, or combustible liquid produced vapors are present that are explodable. - Class 1 Class ____ locations are those that are hazardous because of combustible dust - Class II 3 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE Conductors with _______ Insulation have a greater ampacity when used in a dry location compared to when used in a wet location - THHW When calculating total load for buildings and finding minimum branch circuit load, what must be factored into the volt amps for an exterior electric sign? - Demand load (1.25) Table C.11 and C.11(A) show conductor numbers for size for schedule 40 PVC, what is the difference in charts? - Compact vs stranded conductors 332.30 states that type MI cable shall be supported at intervals of at least how many feet? - Six feet What table sizes equipment grounding conductors for specific over current device

Show more Read less
Institution
Journeyman Electrician
Course
Journeyman electrician









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman electrician
Course
Journeyman electrician

Document information

Uploaded on
December 23, 2024
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1|Page




Journeyman Electrician Practice Test Questions
and Answers 100% Pass


Conductors with _____ marked on the insulation are NOT approved for use in a wet location. -

✔✔THHN




conductors with THHN insulation are approved for use in dry and damp locations only and conductors

with THWN, THHW, and THW insulation are recognized for use in dry and wet locations.


Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt,

single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum

THW conductors required for use as service-entrance conductors for this residence? - ✔✔4/0 AWG




one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of

not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW

aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling.


Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-

family dwelling, the full-load current rating, in amperes, of the secondary is _____. - ✔✔625 amperes




To find the full-load current rating of the single-phase transformer apply the single-phase current

formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes


Which one of the following listed circuit breakers is NOT a standard ampere rating? - ✔✔75 amperes



Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 2|Page




the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere rating of 75

amperes is not a standard ampere rating.


The MINIMUM length of free conductor to be left at each junction box for the purpose of splicing

conductors, or making connections to illuminares or devices shall be _____ . - ✔✔6 inches




free conductor is to be left at each junction box for splices or the connection of luminaires or devices. The

intent of this rule is to ensure enough conductor slack for the terminal connections or splices to be made

easily.


In general, overhead service-drop conductors shall NOT be smaller than _____. - ✔✔8 AWG copper




overhead service-drop conductors to be not smaller than 8 AWG copper or 6 AWG aluminum or copper-

clad aluminum. Do not get service-drop conductors, the overhead conductors between the utility electric

supply system and the service point, confused with the service-entrance conductors, the conductors from

the service point from the utility company to the service disconnecting means.


When a galvanized eye-bolt is to be used as the point of attachment for an electrical service, the NEC

requires the eye-bolt to be installed NOT less than _____ above finished grade. - ✔✔10 ft.




provide adequate vertical clearance of the conductors and prevent physical damage to the conductors

and prevent persons from making accidental contact with the conductors which may create a shock

hazard or electrocution. In no case shall the point of attachment of the service-drop conductors to be less

than 10 ft. above finished grade.




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1092
Member since
2 year
Number of followers
482
Documents
33021
Last sold
2 days ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions