Virginia hic Questions & correct Answers The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs is - ANSWER1 1/8 inches What type of latex coating will not chalk when applied to exterior wall? - ANSWERAcrylic What is the MINIMUM breaking strength required of safety belt lanyards - ANSWER5,400 pounds What is the MINIMUM clearance that combustible insulation MUST other heat-producing devices - ANSWER1 inch What is the MAXIMUM flame spread index for insulation materials - ANSWER25 The amount of water per sack of cement is what controls all EXCEPT - ANSWERset up speed The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of - ANSWER25 feet of the worker What is the correct sequence for installing a bi-fold door - ANSWERTop track, lower track, insert bottom pivot, insert upper pivot What is the MINIMUM height for a stairway handrail - ANSWER34 inches How MUST rafters be framed to each other - ANSWERWith a gusset plate The nailing holes in aluminum and vinyl siding are elongated to allow for - ANSWERExpansion and contraction What are batter boards - ANSWERstakes and ledger boards marking building lines The first step that needs to be taken prior to starting any excavation work is - ANSWERcontracting the local utility companies What is the MAXIMUM distance horizontal reinforcement can be placed from the top of a masonry partition wall - ANSWER16 inches What is the MINIMUM vertical reinforcement spacing for a reinforced concrete foundation wall that is 7 feet high and 10 inches thick on type SP soil - ANSWER56 inches on center A third stairway stringer should be used when the stair width exceeds - ANSWER30 inches Unless otherwise specified, the standard guideline for spacing contraction joints is to space them in feet - ANSWER2 times the stab depth in inches What is the MINIMUM lap of riveted horizontal lap siding - ANSWER1/2inches For multiple-width masonry (mampostería de ancho múltiple) what is the MINIMUM thickness of grout between masonry units and reinforcements? - ANSWER1/4 inch What is the MAXIMUM dimension of the ventilation coverings for under-floor space - ANSWER1/4 inch The MOST specific information about the size and location of windows would be found in a - ANSWERwindow schedule What is the MINIMUM illumination for general constructions area lighting - ANSWER5 foot candles in drywall 3 trim is used to - ANSWERprovide a finish edge What is the MINIMUM number of anchor bolts REQUIRED for anchoring a 12 foot section of wood still plate to a foundation - ANSWERthree bolts What is the MINIMUM square footage of net clear opening area for an egress window in a second floor sleeping area - ANSWER5.70 square feet Which window type consists of an upper and a lower sash that slide vertically in the side jambs - ANSWERDouble hung windows Damp proofing on below-grade masonry foundation walls shall extend from the top of the footing to - ANSWER6 inches above the finished grade Scaffolds MUST remain a MINIMUM of how many feet from a 50-kV power line - ANSWER10 feet

Show more Read less
Institution
Virginia Hic
Course
Virginia hic









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Virginia hic
Course
Virginia hic

Document information

Uploaded on
December 20, 2024
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

Virginia hic Questions & correct Answers
The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs is -
ANSWER1 1/8 inches

What type of latex coating will not chalk when applied to exterior wall? - ANSWERAcrylic

What is the MINIMUM breaking strength required of safety belt lanyards - ANSWER5,400
pounds

What is the MINIMUM clearance that combustible insulation MUST other heat-producing
devices - ANSWER1 inch

What is the MAXIMUM flame spread index for insulation materials - ANSWER25

The amount of water per sack of cement is what controls all EXCEPT - ANSWERset up speed

The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of -
ANSWER25 feet of the worker

What is the correct sequence for installing a bi-fold door - ANSWERTop track, lower track,
insert bottom pivot, insert upper pivot

What is the MINIMUM height for a stairway handrail - ANSWER34 inches

How MUST rafters be framed to each other - ANSWERWith a gusset plate

The nailing holes in aluminum and vinyl siding are elongated to allow for -
ANSWERExpansion and contraction

What are batter boards - ANSWERstakes and ledger boards marking building lines

The first step that needs to be taken prior to starting any excavation work is -
ANSWERcontracting the local utility companies

What is the MAXIMUM distance horizontal reinforcement can be placed from the top of a
masonry partition wall - ANSWER16 inches

What is the MINIMUM vertical reinforcement spacing for a reinforced concrete foundation wall
that is 7 feet high and 10 inches thick on type SP soil - ANSWER56 inches on center

, A third stairway stringer should be used when the stair width exceeds - ANSWER30 inches

Unless otherwise specified, the standard guideline for spacing contraction joints is to space them
in feet - ANSWER2 times the stab depth in inches

What is the MINIMUM lap of riveted horizontal lap siding - ANSWER1/2inches

For multiple-width masonry (mampostería de ancho múltiple) what is the MINIMUM thickness
of grout between masonry units and reinforcements? - ANSWER1/4 inch

What is the MAXIMUM dimension of the ventilation coverings for under-floor space -
ANSWER1/4 inch

The MOST specific information about the size and location of windows would be found in a -
ANSWERwindow schedule

What is the MINIMUM illumination for general constructions area lighting - ANSWER5 foot
candles

in drywall 3 trim is used to - ANSWERprovide a finish edge

What is the MINIMUM number of anchor bolts REQUIRED for anchoring a 12 foot section of
wood still plate to a foundation - ANSWERthree bolts

What is the MINIMUM square footage of net clear opening area for an egress window in a
second floor sleeping area - ANSWER5.70 square feet

Which window type consists of an upper and a lower sash that slide vertically in the side jambs -
ANSWERDouble hung windows

Damp proofing on below-grade masonry foundation walls shall extend from the top of the
footing to - ANSWER6 inches above the finished grade

Scaffolds MUST remain a MINIMUM of how many feet from a 50-kV power line -
ANSWER10 feet

The maximum REQUIREMENT for the thickness of masonry unit bed joints for the second
course shall be - ANSWER3/8 inches

What is not REQUIRED in exterior non bearing walls - ANSWERlow bearing headers

What is the typical exposure of 3-tab asphalt shingles - ANSWER5 inches
$13.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
kielow01

Get to know the seller

Seller avatar
kielow01 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
1 year
Number of followers
0
Documents
3
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions