100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Surgical Technology Certification Exam Questions & Verified Answers | 100% Pass Rate Guaranteed | Latest Updated Version

Rating
-
Sold
-
Pages
48
Grade
A+
Uploaded on
02-12-2024
Written in
2024/2025

The surgeon asks that multiple suture and hernia mesh that were not on the preference card be opened during the repair of a large umbilical hernia. The surgical technologist should recognize that: a. items on the preference card are only to be changed by the surgeon or the unit clerk b. sterile supply associates who stock the hernia mesh are responsible for adding hernia mesh to the preference card c. preference card changes are unnecessary; both hernia mesh and suture are case dependent. d. suture may be case dependent, but the hernia mesh is integral to the procedure and should be added to the preference card Ans Answer: D Which of the following precautions should be taken by the surgical team when working with polymethyl methacrylate as a bone cement? a. wear latex free gloves, as polymethyl methacrylate interacts negatively with latex b. remove contact lenses as polymethyl methacrylate can melt contact lenses and cause corneal burns c. make sure the patient does not have a latex allergy because polymethyl methacrylate and latex have the same chemical properties d. Limit the # of sponges on the field as polymethyl methacrylate can negatively interact with the cotton fibers in the sponges. Ans Answer: B Which of the following daily tests must be performed on the pre-vacuum sterilizer before using it? a. Gravity b. Biological indicator c. Bowie-Dick d. Chemical indicator Ans Page 2 of 48 | © copyright 2024/2025 | Grade A+ Master01 | Dec, 2024/2025 | Latest update Answer: C What is the minimum exposure time in a flash sterilizer for unwrapped instruments? a. 1 minute b. 3 minutes c. 5 minutes d. 7 minutes Ans Answer: B [pre-vac] no lumen - 3 minutes ; lumen - 4 minutes Which of the following is the correct temperature for the flash sterilizer operation? a. 132*C (270*F) b. 126*C (260*F) c. 135*C (275*F) d. 129*C (265*F) Ans Answer: A Which of the following is the proper temperature and time that the chamber of a steam sterilizer must reach in order to ensure that all spores have been eliminated? a. 270*F for 4 minutes b. 350*F for 4 minutes c. 240*F for 10 minutes d. 350*F for 10 mintues Ans Answer: A [pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi The Sterrad sterilization system most commonly uses which of the following chemical solutions? a. hydrogen peroxide b. gluteraldehyde c. alcohol d. peracetic acid Ans Answer: A [Sterrad] make sure its plugged in - needs electricity Page 3 of 48 | © copyright 2024/2025 | Grade A+ Master01 | Dec, 2024/2025 | Latest update Which of the following is used to achieve high level disinfection with a minimum exposure time of 20-45 minutes? a. chlorine bleach compounds b. gluteraldehyde c. hydrogen peroxide d. iodine and iodophors Ans Answer: B During decontamination of a flexible endoscope, which of the following tests should be given to inspect the proper function of the endoscope and to ensure that it can be properly sterilized? a. leak test b. electrical component test c. bacteria swab test d. fiber optic light test Ans Answer: A Which of the fol

Show more Read less
Institution
Surgical Technology Certification
Course
Surgical Technology Certification











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Surgical Technology Certification
Course
Surgical Technology Certification

Document information

Uploaded on
December 2, 2024
Number of pages
48
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Page 1 of 48 | © copyright 2024/2025 | Grade A+




Surgical Technology Certification Exam
Questions & Verified Answers 2024-2025 |
100% Pass Rate Guaranteed | Latest Updated
Version

The surgeon asks that multiple suture and hernia mesh that were not on the
preference card be opened during the repair of a large umbilical hernia. The
surgical technologist should recognize that:
a. items on the preference card are only to be changed by the surgeon or the
unit clerk
b. sterile supply associates who stock the hernia mesh are responsible for
adding hernia mesh to the preference card
c. preference card changes are unnecessary; both hernia mesh and suture are
case dependent.
d. suture may be case dependent, but the hernia mesh is integral to the
procedure and should be added to the preference card
Ans

Answer: D

Which of the following precautions should be taken by the surgical team when
working with polymethyl methacrylate as a bone cement?
a. wear latex free gloves, as polymethyl methacrylate interacts negatively with
latex
b. remove contact lenses as polymethyl methacrylate can melt contact lenses
and cause corneal burns
c. make sure the patient does not have a latex allergy because polymethyl
methacrylate and latex have the same chemical properties
d. Limit the # of sponges on the field as polymethyl methacrylate can
negatively interact with the cotton fibers in the sponges.
Ans

Answer: B

Which of the following daily tests must be performed on the pre-vacuum
sterilizer before using it?
a. Gravity
b. Biological indicator
c. Bowie-Dick
d. Chemical indicator
Ans


Master01 | Dec, 2024/2025 | Latest update

,Page 2 of 48 | © copyright 2024/2025 | Grade A+

Answer: C

What is the minimum exposure time in a flash sterilizer for unwrapped
instruments?
a. 1 minute
b. 3 minutes
c. 5 minutes
d. 7 minutes
Ans

Answer: B

[pre-vac] no lumen - 3 minutes ; lumen - 4 minutes

Which of the following is the correct temperature for the flash sterilizer
operation?
a. 132*C (270*F)
b. 126*C (260*F)
c. 135*C (275*F)
d. 129*C (265*F)
Ans

Answer: A

Which of the following is the proper temperature and time that the chamber of
a steam sterilizer must reach in order to ensure that all spores have been
eliminated?
a. 270*F for 4 minutes
b. 350*F for 4 minutes
c. 240*F for 10 minutes
d. 350*F for 10 mintues
Ans

Answer: A

[pre-vac] temp: 270*F ; time: 3-4 minutes ; pressure: 27 psi

The Sterrad sterilization system most commonly uses which of the following
chemical solutions?
a. hydrogen peroxide
b. gluteraldehyde
c. alcohol
d. peracetic acid
Ans

Answer: A

[Sterrad] make sure its plugged in - needs electricity



Master01 | Dec, 2024/2025 | Latest update

,Page 3 of 48 | © copyright 2024/2025 | Grade A+


Which of the following is used to achieve high level disinfection with a
minimum exposure time of 20-45 minutes?
a. chlorine bleach compounds
b. gluteraldehyde
c. hydrogen peroxide
d. iodine and iodophors
Ans

Answer: B

During decontamination of a flexible endoscope, which of the following tests
should be given to inspect the proper function of the endoscope and to ensure
that it can be properly sterilized?
a. leak test
b. electrical component test
c. bacteria swab test
d. fiber optic light test
Ans

Answer: A

Which of the following is the fastest method of sterilization?
a. gas
b. steam
c. steris
d. dry heat
Ans

Answer: B

Which of the following is the correct temperature for pre-vacuum sterilization?
a. 212*F
b. 170*F
c. 300*F
d. 270*F
Ans

Answer: D

Which of the following tests is specifically meant to test and monitor the
efficiency of the high - vacuum steam sterilizer?
a. biological indicator test
b. DART test
c. chemical indicator test
d. EtO test
Ans




Master01 | Dec, 2024/2025 | Latest update

, Page 4 of 48 | © copyright 2024/2025 | Grade A+

Answer: B

DART test = Bowie Dick test

The surgical team must verify each package is properly labeled with
a. date of processing and method of sterilization
b. date of processing and indicator
c. method of sterilization and expiration date
d. indicator and expiration date
Ans

Answer: B

How many times a day should a DART test be preformed?
a. with every load
b. every shift change
c. once every 24 hours
d. weekly
Ans

Answer: C

How often must a biological control test be run?
a. every day
b. every cycle
c. once a week
d. once a month
Ans

Answer: A

[pg. 163]

The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments
Ans

Answer: B

lot control numbers should be placed on each package sterilized and on the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart
Ans

Master01 | Dec, 2024/2025 | Latest update

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Graders Chamberlian School of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
496
Member since
2 year
Number of followers
167
Documents
25456
Last sold
2 weeks ago
Study Smart

Your one-stop resource for high-quality, exam-focused study materials. Here, you'll find expertly crafted summaries, past exam papers, notes, and assignments tailored to help you succeed in your courses. Every document is written with clarity, accuracy, and exam performance in mind—saving you hours of studying and helping you boost your grades. ✅ Clear and well-structured content ✅ Covers key exam topics and common questions ✅ Trusted by students for academic success ✅ Instant downloads and affordable prices Whether you're cramming for finals or just staying ahead in class, my materials are designed to make your studying smarter, not harder. Take a look around and get the edge you need!

Read more Read less
3.8

120 reviews

5
53
4
26
3
21
2
4
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions