RCD Testing Assessment Questions And Answers Verified Principle And Issues.

Rating
-
Sold
-
Pages
2
Grade
A+
Uploaded on
29-11-2024
Written in
2024/2025

Under which TWO circumstances are the operating times of RCD's required to be tested? - correct answer Where the RCD is used for: 1. Fault Protection against indirect contact (the 1 x test) OR 2. Additional Protection against direct contact (the 5 x test) For each test, why does the RCD need to be tested on the positive and negative half cycles? - correct answer Because each half cycle may produce a different test result If testing on each half cycle produces a different test result, which test result is recorded? - correct answer The longer operating time Prior to RCD testing which other test MUST have been carried out? - correct answer Earth Fault Loop Impedance Why must EFLI testing have been carried out before RCD testing? - correct answer To prove there is a satisfactory earth path for the test current to flow down If an RCD test was performed on a circuit without a satisfactory earth path, what danger would occur? - correct answer The risk of electric shock to anyone in contact with exposed/extraneous conductive parts during the test. Which test instrument is used for RCD testing? - correct answer An RCD tester Where is the RCD test carried out? - correct answer On the load side of the RCD Between which conductors is the RCD test carried out? - correct answer Line and cpc What should be done with any loads on the circuit prior to carrying out the test. - correct answer They should be disconnected What precaution should be taken with people and livestock during the test? - correct answer They should be prevented from touching exposed and extraneous conductive parts of the installation? Under what circumstances is the risk of electric shock during RCD testing at its greatest? - correct answer When the EFLI of the circuit approaches the maximum allowed When tested with 50% of it's rated current how should the RCD react? - correct answer It should not trip When tested with 100% of it's rated current how should an older RCD built to BS4293 react? - correct answer It should trip within 200mS When tested with 100% of it's rated current how should a newer RCD built to BSEN61008 react? - correct answer It should trip within 300mS When tested with 100% of it's rated current how should a socket outlet with a built-in RCD react? - correct answer It should trip within 200mS What is the maximum rating of an RCD, if it is to be used for Additional Protection against direct contact? - correct answer 30mA When tested at 5 times it rated current, an RCD use for Additional Protection must trip within what time? - correct answer 40mS Which other test follows the electrical tests on an RCD? - correct answer A mechanical check that the built-in test button works Under which circumstances will the built-in test button of an RCD NOT work? - correct answer If the RCD is not energised

Show more Read less
Institution
RCD 3700
Course
RCD 3700








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
RCD 3700
Course
RCD 3700

Document information

Uploaded on
November 29, 2024
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

RCD Testing

Under which TWO circumstances are the operating times of RCD's required to be tested? - correct
answer Where the RCD is used for:

1. Fault Protection against indirect contact (the 1 x test)

OR

2. Additional Protection against direct contact (the 5 x test)



For each test, why does the RCD need to be tested on the positive and negative half cycles? - correct
answer Because each half cycle may produce a different test result



If testing on each half cycle produces a different test result, which test result is recorded? - correct
answer The longer operating time



Prior to RCD testing which other test MUST have been carried out? - correct answer
Earth Fault Loop Impedance



Why must EFLI testing have been carried out before RCD testing? - correct answer
To prove there is a satisfactory earth path for the test current to flow down



If an RCD test was performed on a circuit without a satisfactory earth path, what danger would occur? -
correct answer The risk of electric shock to anyone in contact with
exposed/extraneous conductive parts during the test.



Which test instrument is used for RCD testing? - correct answer An RCD tester



Where is the RCD test carried out? - correct answer On the load side of the RCD



Between which conductors is the RCD test carried out? - correct answer Line and
cpc

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
RealGrades Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
168
Member since
2 year
Number of followers
52
Documents
11546
Last sold
6 days ago

4.0

26 reviews

5
12
4
5
3
7
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions