NICET 1 EXAM PRACTICE TEST QUESTIONS AND ANSWERS 100% VERIFIED A room measures 60'ft long by 60'ft wide and has a smooth flat ceiling 10'ft high. A spot-type heat detector with a listed spacing of 30'ft was selected to be installed. According to NFPA 72, what is the minimum number of detectors required? a. 1 b. 2 c. 4 d. 6 - Answer c. 4 According to NFPA 72, line type heat detectors shall be located on the ceiling or on the sidewalks not more than _________. a. 20 inches from the ceiling b. 20 inches from the sidewall c. 30 inches from the ceiling d. 30 inches from the sidewall - Answer a. 20 inches from the ceiling A parallel circuit has a total circuit current of 2 amperes. What is the applied circuit voltage if the total resistance is 6 Ohms? a. 3 Volts b. 0.33 Volts c. 8 Volts d. 12 Volts - Answer d. 12 Volts

Show more Read less
Institution
NICET 1
Course
NICET 1











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NICET 1
Course
NICET 1

Document information

Uploaded on
November 8, 2024
Number of pages
37
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NICET 1 EXAM PRACTICE
TEST 2024-2025
QUESTIONS AND
ANSWERS 100% VERIFIED
A room measures 60'ft long by 60'ft wide and has a smooth flat ceiling 10'ft high. A spot-
type heat detector with a listed spacing of 30'ft was selected to be installed. According
to NFPA 72, what is the minimum number of detectors required?

a. 1

b. 2

c. 4

d. 6 - Answer ✔ c. 4

According to NFPA 72, line type heat detectors shall be located on the ceiling or on the
sidewalks not more than _________.

a. 20 inches from the ceiling

b. 20 inches from the sidewall

c. 30 inches from the ceiling

d. 30 inches from the sidewall - Answer ✔ a. 20 inches from the ceiling

A parallel circuit has a total circuit current of 2 amperes. What is the applied circuit
voltage if the total resistance is 6 Ohms?

a. 3 Volts

,b. 0.33 Volts

c. 8 Volts

d. 12 Volts - Answer ✔ d. 12 Volts

Stairways having _____ or more risers shall be equipped with at least one handrail.

a. 3

b. 4

c. 5

d. 6 - Answer ✔ b. 4

Battery chargers shall be tested ______.

a. Monthly

b. Quarterly

c. Semiannually

d. Annually - Answer ✔ d. Annually

When the top edge of a stair rail system also serves as a handrail, the height of the top
edge shall be more than ______ nor less than ______ from the upper surface of the
stair rail system to the surface of the tread, in line with the face of the riser at the
forward edge of the tread.

a. 37 inches/36 inches

b. 40 inches/36 inches

c. 37 inches/30 inches

d. 40 inches/ 37 inches - Answer ✔ a. 37 inches/36 inches

What is the maximum amount of 12 AWG THHN conductors that can be installed in .75
inch EMT?

a. 9

b. 16

,c. 26

d. 45 - Answer ✔ b. 16

Branch circuits shall have an allowable ampacity of ______.

a. Not less tan 125% of the non continuous load

b. Not less than 100% of the continuous load

c. Not less than 100% of the continuous load and 125% of the non continuous load

d. Not less than 100% of the non continuous load and 125% of the continuous load -
Answer ✔ d. Not less than 100% of the non continuous load and 125% of the
continuous load

Maintenance of the household fire alarm systems be conducted ________.

a. Annually

b. Semi annually

c. Monthly

d. According to the manufacturer's instructions - Answer ✔ d. According to the
manufacturer's instructions

If guards are used to protect a notification appliance such as a strobe light it shall be
_______.

a. Be listed to be used with the appliance

b. Be of metal only

c. Be used on notification appliances that are mounted no higher than 90 inches above
finished floor

d. Guards are not allowed on notification appliances. - Answer ✔ a. Be listed to be used
with the appliance

The alarm audible signal pattern used to notify building occupants of the need to
evacuate shall be the standard alarm evacuation signal consisting of a ______.

a. Two pulse Temporal Pattern

b. Three pulse Temporal Pattern

, c. Accompanying visible signal

d. Voice evacuation instructions - Answer ✔ b. Three pulse Temporal Pattern

Aerial lifts may be "field modified" for uses other than those intended by the
manufacturer provided the modification has been _______________.

a. Tested by the employer prior to its use

b. Reported to OSHA prior to its use

c. Certified in writing by the manufacturer

d. None of the above. Field modifications of aerial lifts are strictly prohibited by OSHA -
Answer ✔ c. Certified in writing by the manufacturer

In every building or structure exits shall be so arranged and maintained as to provide
free and unobstructed egress from all parts of the building or structure ______.

a. At all times when it is occupied

b. During construction only

c. That is accessible to personnel

d. None of the above - Answer ✔ a. At all times when it is occupied

All fire alarm systems shall test free of ______.

a. Dirt

b. Errors

c. Grounds

d. Power Loss - Answer ✔ c. Grounds

The secondary power supply for in building mass notifciation systems shall be capable
of operating the system for a minimum of _____ and shall be capable of operating the
system during emergency condition for ____ at maximum connected load.

a. 24 Hours/ 15 Minutes

b. 24 Hours/ 5 Minutes

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Scholarsstudyguide nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
777
Member since
3 year
Number of followers
475
Documents
14976
Last sold
11 hours ago
NURSING

Here you will find everything you need in nursing Assignments, EXAMS AND TESTBANKS. For students who want to see results twice as fast. I strive for my content to be of the highest quality. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.9

163 reviews

5
87
4
21
3
25
2
6
1
24

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions