Fire pump Exam
preparation/Questions with Answers
1. The purpose of inspection shall be to verify that the pump assembly - -
Appears to be condition and is free from physical damage

- 2.The 5 pertinent visual observations specified in the NFPA 25 checklist
that shall be performed weekly are - -1 Pump house condition 2 pump
system conditions 3 electrical system conditions Diesel engine system
conditions 5 steam system conditions

- 3.Part of the check of the pump house conditions is that : - -ventilating
louvers are free to operate

- 4. During the weekly inspection the pump suction discharge and bypass
valves should be observed to be : - -OB fully open

- 05. During the weekly inspection , the suction reservoir should be observed
to be : - -A full

- 6. As observed during the weekly inspections wet pit suction screens
should be - -Unobstructed and in place

- 7. During the weekly inspection of the pump assembly the controller pilot
light should be - -Illuminated (power on)

- 8. During the weekly inspection of the pump assembly the transfer switch
normal pilot light should be - -Illuminated (power on)

- 9 During the weekly inspection of the pump assembly the isolating switch
should be observed to be - -Closed

- 10 During the weekly inspection of the pump assembly the reverse phase
alarm pilot light should be observed to be - -Off

- 11. During the weekly inspection of the pump assembly the normal phase
rotation pilot light should be observed to be - -On

- 12, during the weekly inspection of the pump assembly the oil level in the
vertical motor sight glass should be observed to be - -Normal

- 13.During the weekly inspection of the pump assembly the fuel tank
should be observed to be - -Two-thirds full

, - 14.during the weekly inspection of the pump assembly the controller
selector switch should be in ___________ position - -Auto

- 15. During the weekly inspection of the pump assembly all alarm pilot
lights should be - -Off

- 16.During the weekly inspection of the pump assembly the engine
running________ meter is reading - -Time

- 17. During the weekly inspection of the pump assembly the oil level in the
______gear drive should be normal - -Right angle

- 18. During the weekly inspection of the pump assembly the electrolyte
level in batteries should read - -Normal

- 19. A weekly test of the fire pump assemblies shall be conducted - -
Without flowing water

- 20. The pump test shall be conducted by starting the pump automatically -
-True

- 21. A weekly test of the fire pump assembly shall be conducted by starting
the pump without flowing water. The electric pump shall be run a minimum
of. - -10 minutes

- 22. A weekly test of the fire pumps assembly shall be conducted by
starting the pump without flowing water. The diesel pump shall run a
minimum of. - -30 minutes

- 23. During the weekly test of the fire pump assemblies, an installed safety
relief valve shall. - -Permit water to flow

- 24. What can be substituted for the normal starting procedure of the
weekly test of the fire pump assemblies - -An automatic weekly test timer

- 25.During the weekly fire pump, test what pressure gauge readings should
be recorded. - -Suction and discharge pressures

- 26. Pump packing plants should have ____ - -Slight discharge of water

- 27. During the weekly test of the fire pump, assemblies, one must observe
the time it takes for the motor to accelerate to. - -Full speed

- 28. During the weekly check of the electrical system what is recorded after
starting the pump to check the automatic stop controller. - -The time pump
runs after starting

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AccurateScores Not yet listed
View profile
Follow You need to be logged in order to follow users or courses
Sold
552
Member since
3 year
Number of followers
336
Documents
15259
Last sold
6 days ago

3.7

113 reviews

5
51
4
18
3
18
2
11
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions