QUESTIONS |GUARANTEED
ACCURATE ANSWERS
Which of the following are a type of sprinkler?
A) ESFR
B) EC
C) AF
D) A and B - ACCURATE ANSWERS✔✔ A and B
Foam water system design and installation requirements are regulated by
___________.
A. NFPA 13
B. NFPA 13R
C. NFPA 25
D. NFPA 16 - ACCURATE ANSWERS✔✔ NFPA 16
True or False, NFPA 72 allows only manual pull stations and water flow
detection devices to be used on shunt systems. Fire detection devices are
not permitted. - ACCURATE ANSWERS✔✔ True
The fire alarm control panel (FACP) is essentially the _____ of the
system. - ACCURATE ANSWERS✔✔ Brain
,Heat sensing fire detector color coding has a RED extra high
temperature rating of?
A.) 0-99f
B.)175-249f
C.) 325-399f
D.) 500-575f - ACCURATE ANSWERS✔✔ 325-399f
According to NFPA, travel distances to a manual pull station should not
exceed _____ feet.
A. 100
B. 200
C. 300
D. 400 - ACCURATE ANSWERS✔✔ 200
What color tag is used to indicate that an alarm system is impaired?
A. White
B. Yellow
C. Blue
D. Red - ACCURATE ANSWERS✔✔ Red
About _____ % of fire deaths are attributed to smoke inhalation and not
to burns.
A. 55%
B. 60%
,C. 65%
D. 70% - ACCURATE ANSWERS✔✔ 65%
When performing maintenance inspections of occupancies with alarm
systems, the first step will be to:
A) Check for green light indicating normal operation
B) Confirm monitoring status with alarm company
C) Confirm panel is locked and inaccessible to public
D) Confirm system has been tested by licensed alarm contractor and has
a current inspection tag - ACCURATE ANSWERS✔✔ Confirm system
has been tested by licensed alarm contractor and has a current inspection
tag
Most people are well aware of the dangers of fire but less aware of the
dangers of smoke inhalation. About ___% of of fire deaths are attributed
to smoke inhalation and not to burns.
A) 65
B) 80
C) 92
D) 75 - ACCURATE ANSWERS✔✔ 65
If required, pull stations should be placed within ___ feet of every exit.
a) 4
b) 5
c) 10
, d) does not matter what distance, as long as it is not blocked -
ACCURATE ANSWERS✔✔ 5
T or F: The development of clean-agent fire-extinguishing systems
began in the late 1940s. - ACCURATE ANSWERS✔✔ True
NFPA 10 has assigned a maximum travel distance of __ feet from the
hazard to a Class K extinguisher?
A) 30
B) 50
C) 75
D) 100 - ACCURATE ANSWERS✔✔ 30
If an extinguisher is suitable for use on a particular class of fire, the
picture-symbol background is what color?
A.) Red
B.) Light Blue
C.) Black
D.) Grey - ACCURATE ANSWERS✔✔ Light Blue
Which one of the following is not considered a proper placement of a
fire extinguisher?
A. Visible and marked with legible signage.
B. Near Points of egress or ingress.