ICC FIRE PLANS EXAMINER QUESTIONS
1 hour wall for brick(rated fire resistance periods for various walls and partitions -
Answers- 2.7 inches, IBC Table 721.1(2)

Arrive on a construction site and sprinkler contractor asks if sprinkler can pass through
steel beams - Answers- Ask building official IBC 104.10

Protection around LPG tanks - Answers- IFC 312.2 and NFPA 58, 6.27.3.13

Spaces with one exit or exit access doorway. 2 story building with occupant load of 30
on each floor, how many people can door handle? - Answers- 49 occupant load, IFC
and IBC Table 1006.2.1

How many exit doors in a boiler room? - Answers- Two exits access doorways are
required in rooms over 500 square feet and exceeds 400,000 BTU. IFC and IBC
1006.2.2.1

What is the minimum width of Fire access road? - Answers- 20 ft IFC 503.2.1

Minimum feet for hydrant at new facility - Answers- 400 ft IFC 507.5.1


What code provides emergency power generator for high-rise buildings? - Answers-
NFPA 110 Standard for Emergency and Standby Power, Ch 80 Referenced Standards

Can you utilize alternate extinguishing system on a two story building? - Answers- Up
to AHJ, IFC and IBC 904.2

What is the minimum standpipe riser protection? - Answers- Risers and laterals of
Class I standpipe systems not located within an exterior exit shall be protected by a
degree of fire resistance equal to that required for vertical enclosures in the building in
which they are located, IFC and IBC 905.4.1

What is the proper clearance for marine motor fuel dispensing location? - Answers- 50
feet, IFC 2310.5.5

The area surrounding an outdoor storage area or tank shall be kept clear of combustible
materials and vegetation for a minimum distance of? - Answers- 25 ft, IFC 5004.11

What is the minimum piping systems and testing for flammable and combustible liquids?
- Answers- Unless tested in accordance with ASME B31.9, piping before being covered
enclosed or placed in use shall be hydrostatically tested to 150%........ IFC 5703.6.3

When are plans required for LP-gas? - Answers- Single container 2,000 gallon.
Aggregate 4,000 gallons IFC 6101.3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
2003
Member since
3 year
Number of followers
1445
Documents
47760
Last sold
12 hours ago

3.8

342 reviews

5
170
4
61
3
44
2
16
1
51

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions