The ESMC node board requires which of the following input voltages? - Answers 24VDC and 48VDC
The Watchdog board is part of which subsystem? - Answers Safety Chain
Repeater board is most commonly found in which module? - Answers Chassis
The CMC node board requires which of voltage? - Answers 24VDC
The Repeater board is part of which circuit? - Answers Safety Chain
Which motors are controlled via an ESMC board - Answers NEMA 17 and NEMA 23
The ESMC and CMC node boards contain how many physical nodes - Answers 4
What voltage does a repeater board require? - Answers 24VDC
How many inputs do ESMC and CMC boards support? - Answers 11
How many outputs do ESMC and CMC boards support? - Answers 8
How many E-stop and interlocks do ESMC and CMC boards support - Answers 2 E-stop 3 Interlocks
Which motors are controlled with a CMC board? - Answers Emerson and Baldor
Which nodes are supported on ESMC and CMC boards? - Answers 2 servo, 1 analog, 1 I/O
What are the correct servo motor connections on an ESMC board? - Answers 2 Hall, 2 Encoder, and 2
Power/Phase
What are the correct servo motor connections on a CMC board? - Answers J2 Amp control and J4 Amp
control
How many Grounding planes are there on ESMC and CMC boards? - Answers 4
Which of the following diagnostic tools provides real-time histogram of events? - Answers Health
Monitor
What is the best diagnostic tool for troubleshooting intermittent photocell flicker? - Answers Logic
analyzer
In order to acquire additional information regarding the 4-digit code that is displayed in a DC error
message, which tool would you use? - Answers Faults dialog
Which icon/tool would you use in DC to select the Servo Diagnostic tool? - Answers Node List
True or False: The Rocket Port connects to the Chassis RTP - Answers False
, What is the purpose for the Health Check button located at the bottom of the Node Card I/O dialog box?
- Answers To test photocells
True or False: The inserter uses time-base for tracking and mail pieces - Answers False
The Health Monitor and the Shutdown script uses which type of communications? - Answers Ethernet
Can you use a White LED to replace a Grey LED? - Answers No
What can you use to determine if a photocell is operating properly? - Answers Flashlight
What can you use to determine if the LED is operating properly? - Answers Phone camera
What do you use to troubleshoot a photocell on a Bingo Board? - Answers Voltmeter and a piece of
paper
Ture or False: You can use the Serial Diagnostics to troubleshoot scanning - Answers True
What diagnostics tools acan be used to troubleshoot "Over Run" errors? - Answers Health Monitor,
Logic Analyzer
In the Logic Analyzer, what do the Vertical Green and Red Lines mean? - Answers Green is "Machine
Start" and Red is "Error"
What will the Keyboard Up, Down, Left, and Right arrows do in the Logic Analyzer? - Answers Zoom in
and out and scroll left/right
What are the correct voltages of a photocell? - Answers Greater than 4v Blocked and less than 0.5v
unblocked
Where can you go in DC to view Photocell voltages - Answers Node I/O
What is the correct voltage range for a proximity sensor? - Answers Less than 0.5v on target and greater
than 6v off target
Where would you go to activate an output in DC? - Answers Node I/O
True or False: The Node I/O screen in DC can be used to help troubleshoot an interlock issue - Answers
True
What does the Toggle Box in the Node I/O do? - Answers Cycles output On/Off until the box is
unchecked AND verifies that the output device functions
What do the outputs M-1 thru M-8 represent? - Answers Mexxanine Board Outputs (QMM)
Can Auto Toggle be used to troubleshoot motors? - Answers No
What is the voltage on an interlock's brown wire pair? - Answers 24vdc