100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Journeyman Oil Maine Fuel Board Rules

Rating
-
Sold
-
Pages
34
Grade
A
Uploaded on
15-10-2024
Written in
2024/2025

Journeyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesJourneyman Oil Maine Fuel Board RulesWhat must you do if you notice code violations in a homeowners house? - ANSWER-Notify them and recommend ways to address them What must be done when performing an annual tune-up on a heating system? - ANSWER-A combustion efficiency test and a copy must be posted on site Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation must be brought into compliance with what requirements BEFORE appliance can be fired? - ANSWER-NFPA 31

Show more Read less
Institution
Journeyman Oil Maine Fuel Board Rules
Course
Journeyman Oil Maine Fuel Board Rules











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman Oil Maine Fuel Board Rules
Course
Journeyman Oil Maine Fuel Board Rules

Document information

Uploaded on
October 15, 2024
Number of pages
34
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Journeyman Oil Maine Fuel Board

Rules


What must you do if you notice code violations in a homeowners house? -

ANSWER-Notify them and recommend ways to address them




What must be done when performing an annual tune-up on a heating

system? - ANSWER-A combustion efficiency test and a copy must be posted

on site




Whenever a furnace, direct fired hot water heater, or boiler is installed the

total installation must be brought into compliance with what requirements

BEFORE appliance can be fired? - ANSWER-NFPA 31




When an emergency arises that does not allow adequate time to get a

chimney lined/and or repaired before installing the new heating appliance

the licensee may defer the required repairs for how long? - ANSWER-90 days

,What must be performed before a new installation? - ANSWER-A heat loss

system design and load calculation. A copy must be retained to be presented

upon request of board inspector




What may be installed in the supply line but not a return line? - ANSWER-A

check valve




If the low water cut off is not installed directly in the boiler where may it be

installed? - ANSWER-Main supply line (vertical riser) as close to boiler as

possible, or in a water column of continuous piping attached directly to the

boiler




A listed lever or wheel thermally operated oil shut off valve must be installed

where? - ANSWER-At the burner and the oil supply tank




When outside tanks are used a thermally operated shut off valve must be

installed where? - ANSWER-The supply line enters the inside of the building

and where the oil line enters the room where the appliance is located

,When inside tanks are used and the oil supply tank is installed in a separate

room, a thermally shutoff valve must be installed where? - ANSWER-Where

the line enters the room where the appliance is located




All copper oil supply and return lines must be encased in a continuous piece

of no metallic liquid tight conduit such as PVC, ENT, coated copper tubing.

The end of the conduit shall not exceed how far from any connection except

the connection at fuel tank? - ANSWER-2 inches




All oil fired BOILERS must be provided with a properly installed and operating

what? - ANSWER-Low Water cut off




Where shall a low water cutoff be installed? - ANSWER-At the level

recommended by the manufacture, but in no case below the crown sheet




Whenever the oil supply is taken from the top of an oil tank a thermally

operated wheel or lever type shut-off valve must be installed where? -

ANSWER-At the tank and at the burner

, In order to avoid undetected oil leaks under floors, the conduit must be how

much bigger than the supply and return lines? - ANSWER-One pipe size

larger




An oil supply line that penetrates a foundation wall must be what? -

ANSWER-Sealed




What must coated copper tubing have installed at the tank when used

underground? - ANSWER-Oils Safety Valve or PRV




When an oil filter or other accessory equipment is connected to a copper

piping smaller than 3/4 "and is not directly connected to the oil tank or

burner the filter or other device must be what? - ANSWER-Rigidly supported

by wall or floor mounted brackets




What must supply and return lines be connected with? - ANSWER-Flare

fittings




What fittings shall not be used unless for introduction of lines at top of the

tank with a single or double tap bushing? - ANSWER-Compression fittings

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
NursingTutor1 West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1618
Member since
2 year
Number of followers
1073
Documents
18045
Last sold
14 hours ago
Nursing Tutor

Paper Due? Worry not. Hello. Welcome to NursingTutor. Here you\'ll find verified study materials for your assignments, exams and general school work. All papers here are graded A to help you get the best grade. Also, I am a friendly person so, do not hesitate to send a message in case you have a query. I wish you Luck.

3.9

442 reviews

5
210
4
76
3
87
2
21
1
48

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions