Which radiation hazard category describes the danger of detonation or device failure resulting
from exposing electrically initiated devices (EIDs) to EMR? - ANSWER--HERO




Which type of LPS is identified in the image below? - ANSWER--Mast




How many down conductors are required for a building with a perimeter length of 425 feet? -
ANSWER--WRONG 3




Which publication provides detailed information on Hazards of Electromagnetic Radiation to
Ordnance (HERO)? - ANSWER--AFI 91-208




Which two publications provide detailed information on lightning protection systems? -
ANSWER--DA PAM 385-64
NFPA 780
Which statements about lightning protection are true?Select all that apply. - ANSWER--
Lightning can detonate munitions and explosives.




Lightning seeks the path of least resistance to ground.




Lightning cannot be stopped or prevented.
Which statement is true about a mast LPS? - ANSWER--Each mast must have two paths to
ground.

,A 30-foot tall building is protected by a catenary system. How far from the building should the
masts be placed? - ANSWER--at least 6 feet


Which LPS uses air terminals and conductors mounted directly to the structure? - ANSWER—
Integral


Why does the wooden mast have an air terminal on top and two down conductors running its
entire length? - ANSWER--The wooden mast is not electrically conductive


Which of the following is NOT a requirement for air terminals? - ANSWER--Air Terminals must
be at least 6 feet tall.]


During the inspection, John's team logged a discrepancy for this air terminal. Why? - ANSWER--
The air terminal is not attached to a conductor.




How many down conductors are required for a building with a perimeter length of 325 feet? -
ANSWER--4
While conducting an LPS inspection, you see mast down conductors routed as shown in the
image below. Do you write it up as a discrepancy? Why or why not?
- ANSWER--Yes, because mast down conductors should be 180 degrees apart.
A steel beam, connected to the main LPS at its upper and lower extremities, is used as a down
conductor. At what intervals should it be connected to the grounding system? - ANSWER--60
feet or less
Which statement about grounding systems is true? - ANSWER--The resistance should be 25
ohms or less.
Which of the following statements regarding bonding are true? Select all that apply. - ANSWER-
-Bonding reduces the threat of sideflash by providing a low impedance path to ground.




Bonding is a way of connecting LPS conductors to grounded metal objects.
When should a grounded metal object be considered for bonding? - ANSWER-- When it's within
6 feet of a conductor
Which bonding method is the most permanent and secure? - ANSWER-- Exothermic weld

, Which factors are used to calculate bonding distance?Select all that apply. - ANSWER--Height of
proposed bond




Flashover medium




Number of down conductors




While conducting the inspection, John's team noticed a new metal light pole installed 3 feet
from the down conductor at the corner of this building. They logged a discrepancy. Why? -
ANSWER--Because grounded metal objects within 6 feet of LPS conductors should be bonded to
it
Which types of information does an LPS record provide? Select all that apply. - ANSWER--Test
locations




Test item descriptions or listing




Type of test




Responsibilities for conducting and administering the test plan
Which section of DA PAM 385-64 provides LPS visual inspection guidance? - ANSWER--Appendix
D
How often is a visual inspection required on an LPS? - ANSWER--Every 12 months While
conducting the LPS inspection, the team saw these surveillance cameras.
Does this building comply with LPS standards? - ANSWER--No, because the surveillance cameras
are outside the zone of protection.
How long must LPS test results be kept on file? - ANSWER--6 inspection cycles

Written for

Institution
ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO28 EXA
Course
ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO28 EXA

Document information

Uploaded on
October 10, 2024
Number of pages
25
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
dennohz2000 Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
222
Member since
2 year
Number of followers
47
Documents
5308
Last sold
22 hours ago

4.1

56 reviews

5
34
4
8
3
6
2
2
1
6

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions