fresenius medical care PCT test-69
Questions Solved 100% Correct
The number one cause of chronic renal failure is? - Answer Diabetes
When going from a dirty area to retrieve supplies in a clear area, staff is required
to complete hand hygiene? T or F - Answer True
Hazardous Materials Identification System (HMIS) Label are required on all
hazardous materials including individual bicarbonate containers? - Answer True
What soultion should be used t disinfect a large blood spill area (Greater that 10mL)? -
Answer 1 to 10 bleach solution
The main rout of transmission of Hepatitis B in Hemodialyis Facilities is by exposure to
Infected _________ and _______? - Answer Infected blood and Body Fluids
When Caring for a patient who is Hepatitis B positive, After disconnecting the
bloodlines, the tech MUST perform which 3 actions before documenting? -
Answer Remove Gloves, Sanitize Hands, put on a fresh pair of gloves
, Patients who are hepatitis B surface B antigen Positive should be dialyzed in a
_______________ area of the dialysis center on a ______________ machine? - Answer
Separate, Dedicated
What PPE should you wear when documenting in the isolation room? - Answer
Clean Gloves
The tech has performed a rinseback on a patient and failed to gather supplies needed to
disconnect the patient. What 2 things MUST the tech do prior to getting clean supplies?
- Answer Remove Gloves, Wash/Sanitize Hands
Dialysate used for in center hemodialysis is? - Answer Non-Sterile
Who ultimately determins the dialysate bath used for a patients treatment? - Answer
Physicians ONLY!!!
Individual Acid containers must be __________ with chemical content - Answer Labeled
Three soultes that may be present in a prescribed dialysate solution? - Answer
Sodium Bicarbonate, potassium and Calcium
A major complication that occurs when the patient is dialyzed on a hypo tonic
dilysate is? - Answer Hemolysis
The __________area of the dialysate hs the most impact on dialyzser clearance -
Answer surface
Which of the following would ADVERSELY affect clearance? - Answer Air in the Dialyzer
Questions Solved 100% Correct
The number one cause of chronic renal failure is? - Answer Diabetes
When going from a dirty area to retrieve supplies in a clear area, staff is required
to complete hand hygiene? T or F - Answer True
Hazardous Materials Identification System (HMIS) Label are required on all
hazardous materials including individual bicarbonate containers? - Answer True
What soultion should be used t disinfect a large blood spill area (Greater that 10mL)? -
Answer 1 to 10 bleach solution
The main rout of transmission of Hepatitis B in Hemodialyis Facilities is by exposure to
Infected _________ and _______? - Answer Infected blood and Body Fluids
When Caring for a patient who is Hepatitis B positive, After disconnecting the
bloodlines, the tech MUST perform which 3 actions before documenting? -
Answer Remove Gloves, Sanitize Hands, put on a fresh pair of gloves
, Patients who are hepatitis B surface B antigen Positive should be dialyzed in a
_______________ area of the dialysis center on a ______________ machine? - Answer
Separate, Dedicated
What PPE should you wear when documenting in the isolation room? - Answer
Clean Gloves
The tech has performed a rinseback on a patient and failed to gather supplies needed to
disconnect the patient. What 2 things MUST the tech do prior to getting clean supplies?
- Answer Remove Gloves, Wash/Sanitize Hands
Dialysate used for in center hemodialysis is? - Answer Non-Sterile
Who ultimately determins the dialysate bath used for a patients treatment? - Answer
Physicians ONLY!!!
Individual Acid containers must be __________ with chemical content - Answer Labeled
Three soultes that may be present in a prescribed dialysate solution? - Answer
Sodium Bicarbonate, potassium and Calcium
A major complication that occurs when the patient is dialyzed on a hypo tonic
dilysate is? - Answer Hemolysis
The __________area of the dialysate hs the most impact on dialyzser clearance -
Answer surface
Which of the following would ADVERSELY affect clearance? - Answer Air in the Dialyzer