Actual Exam Questions and CORRECT
Answers
Type of sealant you should you use on a Phil-Tite Ball Float nipple: - CORRECT
ANSWER✔✔- Pipe dope
Number of open valves on the clean air separator: - CORRECT ANSWER✔✔- One
You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? -
CORRECT ANSWER✔✔- False
The type of pressure gauge is recommended to test Healy Vac - CORRECT ANSWER✔✔-
SYSA gauge measuring 0-100 WC
On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? -
CORRECT ANSWER✔✔- YES-When Piping is monitored and with VAC
According to Executive Order 201 - Healy P/V Valve should be torqued at - CORRECT
ANSWER✔✔- 20-50 ft-lbs
For a fire to burn, these (3) three primary elements must exist: - CORRECT ANSWER✔✔-
Fuel, Oxygen, Ignition Source
When working with Electrical - Lock Out Tag Out procedures are under these guidelines. -
CORRECT ANSWER✔✔- CAL-OSHA
Organization that certifies vapor recovery systems. - CORRECT ANSWER✔✔- CARB or
ARB
According to RP 500, a level II technician may NOT inspect this part. - CORRECT
ANSWER✔✔- Replace VP 1000 Healy Pump
, where hanging hardware repairs must be tracked. - CORRECT ANSWER✔✔- GDF
maintenance log
approved sealant when assembling a Phil-Tite Drop Tube. - CORRECT ANSWER✔✔- JB-
Kwik
Material direct bury OPW container sleeve shall be made of. - CORRECT ANSWER✔✔-
Stainless steel
What P/V vent cap shall be tightened to. - CORRECT ANSWER✔✔- 20-50 ft lbs
From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank -
3" diameter vapor piping (3" ID) - CORRECT ANSWER✔✔- Vapor piping
What is the maximum run for vapor piping? - CORRECT ANSWER✔✔- No maximum run
How you know a nozzle spout is bad. - CORRECT ANSWER✔✔- 'BAD O-rinqs
According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors
typically flow in what direction of the coaxial hose? - CORRECT ANSWER✔✔- The outside
pathway
What is the maximum allowable number of P/V caps allowed on a UST fuel system? -
CORRECT ANSWER✔✔- One
On a Healy Air Separator, there are four Ball Valves, the following shall be observed? -
CORRECT ANSWER✔✔- One valve shall remain open on top
The Pressure settings for the UST Vent Cap is. - CORRECT ANSWER✔✔- .0+- 0.5inches
H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure