WITH 100% ACCURATE SOUTIONS
What is the minimum space between ground rods? - Precise Answer ✔✔Six feet
What color triangle marking will be on a noise cancelling outlet? - Precise Answer ✔✔Orange
Fraud, deceit, or willful violation of the electrical administrative act may incur of a fine of.... - Precise
Answer ✔✔Not more than $10,000
An electrical contractor doesn't need a permit for.... - Precise Answer ✔✔Minor work $100 or less
A master must be _ to qualify for the electrical examination - Precise Answer ✔✔22 years of age and
12,000 hours
A journeyman must be _ of experience - Precise Answer ✔✔20 years of age and 8,000 hours
Bonding to a pool grid has to have what type of devices - Precise Answer ✔✔Pressure devices
Convenience outlets must be GFCI and located between _ and _ of the inside of the wall of a pool -
Precise Answer ✔✔6ft and 20ft
Type RTRC shall be permitted to be unsupported where the raceway is not more than __ long and
remains in unbroken lengths and terminated in an outlet box - Precise Answer ✔✔3 feet
Receptacle outlets shall be installed so that no point along the wall line of a kitchen countertop is more
than _ inches measured horizontally from a receptacle outlet in that space - Precise Answer ✔✔24
inches
, What is the minimum size THW conductor that can be used to supply a 200A single phase commercial
building - Precise Answer ✔✔3/0 copper
What is the minimum rating for a laundry circuit in a single family dwelling - Precise Answer ✔✔20 AMP
1500 watts
What is the expansion rate of 250 feet of pvc that goes from a temperature change of -20°F to 80°F -
Precise Answer ✔✔10.15
For photovoltaic systems, what cannot be connected to the supply side - Precise Answer ✔✔A non-
overcurrent light/device
Pool pump receptacles must be at least _ feet from the inside of a pool - Precise Answer ✔✔10 feet
A boat hoist receptacle shall be mounted not less than ________ above the deck surface of the pier and
not below the electrical datum plane on a fixed pier - Precise Answer ✔✔12 inches
When a metal enclosure is required to protect the grounding electrode conductor, the enclosure has to
be bonded to what at both ends? - Precise Answer ✔✔Grounding electrode conductor
Where a portable optional standby source is used as a ________ it shall be grounded to a grounding
electrode - Precise Answer ✔✔Separately derived system
In general care areas, patient bed locations shall be provided with a minimum of _ receptacles - Precise
Answer ✔✔8 for general
14 for critical
What type of cable can't be used as a ground for critical and EM branch circuits of a hospital - Precise
Answer ✔✔Isolated ground
Master or journeyman electrical license issued in Michigan expires _ of each year and must be renewed
within _. Not renewing in time may result in loss of license and additional fees - Precise Answer
✔✔December 31st, 60 days