FIRST PUBLISH SEPTEMBER 2024
2024 VA HIC License Exam Prep
Questions and Answers |100% Pass
Protruding objects may not protrude more than ___ inches into the path of travel. - Answer✔✔-4"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 15
In new buildings, thresholds at doorways should be no higher than ______. - Answer✔✔-1/2"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 30
In a Type A unit, if measuring to the highest part of the rim or highest part of the counter, what is the
maximum height of the sink front above the floor? - Answer✔✔-34"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 149
The height of handrails shall be ____ minimum and ____ maximum vertically above stair nosings, ramp
and walking surfaces. - Answer✔✔-34" minimum, 38" maximum
Page 1/65
,EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 62
A hallway more than 24 inches long must have a clear width of ____. - Answer✔✔-36"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19
Enter and proceed" is presented as a _____ on the raised touchable surface on a function key." -
Answer✔✔-Circle
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 107
Operable parts shall be operable with one hand and shall not require: - Answer✔✔-Tight grasping,
pinching, or twisting of the wrist.
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 18
Page 2/65
,EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024
In existing buildings and facilities, the clear width of a walking surface shall be permitted to be reduced
to ____ minimum for a length of 24 inches maximum. - Answer✔✔-32 inches
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19
The clear width of an exterior accessible route located within seating areas shall be ___ minimum. -
Answer✔✔-36 inches
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19
The running slope of walking surfaces shall not be steeper than: - Answer✔✔-1:20
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19
What components shall not be part of an accessible route? - Answer✔✔-Revolving doors & Turnstiles
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19
Page 3/65
, EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024
The maximum height of existing elevator call buttons shall be permitted to be located ___ above the
floor. - Answer✔✔-54"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 40
The maximum knee clearance shall be permitted to extend ____ under an element that is 9" above the
floor. - Answer✔✔-25"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 13
The brightness of the elevator car landing sill, threshold, platform and controls are to be no less than
_____ foot candles. - Answer✔✔-5
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 51
What is the least diameter of grab bars with circular cross sections? - Answer✔✔-1-1/4"
ANSI Accessible and Usable Buildings and Facilities, 2017
Page 4/65