100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NCLE Advanced Certification Exam Questions Answered Correctly.

Rating
-
Sold
-
Pages
155
Grade
A+
Uploaded on
26-09-2024
Written in
2024/2025

The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by changing the anterior optical zone, will not affect the sagittal depth of the lens, nor will changing its edge design. - Answer 1. The sagittal depth of a rigid gas permeable contact lens can be altered without changing the diameter by: A. Changing the power B. Changing the edge design C. Changing the radius of curvature of the anterior optical zone D. Changing the radius of curvature of the posterior optical zone The answer is A. A lens is truncated by removing a segment of the lower edge of a contact lens. This creates a straight edge that interacts with the lower lid and aids in lens positioning. Of the lens designs listed in the question, the only one that requires precise positioning of its optical portions is a translating bifocal lens. - Answer 2. A truncation is used on a rigid gas permeable contact lens to help enhance the performance of which type of design? A. Bifocal B. Aphakic C. Bitoric D. Keratoconus The answer is B.

Show more Read less
Institution
NCLE
Course
NCLE











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NCLE
Course
NCLE

Document information

Uploaded on
September 26, 2024
Number of pages
155
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NCLE Advanced Certification Exam
Questions Answered Correctly.
The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas permeable
lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it is flattened, it will
decrease the sagittal depth. Changing the power, which is accomplished by changing the anterior optical
zone, will not affect the sagittal depth of the lens, nor will changing its edge design. - Answer 1. The
sagittal depth of a rigid gas permeable contact lens can be altered without changing the diameter by:



A. Changing the power

B. Changing the edge design

C. Changing the radius of curvature of the anterior optical zone

D. Changing the radius of curvature of the posterior optical zone



The answer is A.



A lens is truncated by removing a segment of the lower edge of a contact lens. This creates a straight
edge that interacts with the lower lid and aids in lens positioning. Of the lens designs listed in the
question, the only one that requires precise positioning of its optical portions is a translating bifocal lens.
- Answer 2. A truncation is used on a rigid gas permeable contact lens to help enhance the
performance of which type of design?



A. Bifocal

B. Aphakic

C. Bitoric

D. Keratoconus



The answer is B.

,A lenticular or myoflange design will decrease the mass of an aphakic lens as well as increase the edge
profile, which allows it to interact more with the upper lid and aid in positioning of the lens. - Answer
3. The mass of an aphakic rigid gas permeable contact lens can be reduced by making the lens design:



A. Spherical

B. Lenticular

C. Tricurve

D. Aspheric



The answer is B.



Increasing the optical zone diameter and increasing the overall lens diameter will both tighten and
steepen the relationship of the lens to the cornea. Decreasing the optic zone diameter will serve to
flatten and loosen the lens to cornea relationship. Using a prism-ballasted lens design will not affect the
lens to cornea relationship as it relates to sagittal depth. - Answer 4. In order to tighten the fit of a rigid
gas permeable lens you can:

I. Increase the optical zone diameter

2. Decrease the optical zone diameter

3. Increase the overall lens diameter

4. Use a prism ballasted lens design



A. 3 only

B. 1&3

C. 2 only

D. 2&3



The answer is D.



A hyperflange will decrease edge thickness as well as lens awareness . Aspheric peripheral curves change
the posterior design of the lens but do not reduce edge thickness. A higher Dk material will not change
the overall lens edge thickness. A myoflange will actually add thickness to the lens edge and is used for

,high plus lenses not high minus lenses. - Answer 5. A high minus rigid gas permeable lens will be thin
centrally with relatively thick edges. To reduce the edge thickness, and increase overall comfort, use:



A. Aspheric peripheral curves

B. A myoflange

C. A higher Dk material

D. A hyperflange



The answer is C.



One would rarely polish or attempt to manipulate the central posterior surface of a rigid lens. Applying
polishing pressure to the mid-peripheral and the peripheral anterior surface would add plus power.
Applying polishing pressure to the central anterior surface would add minus power. - Answer 6. To add
minus power to a rigid contact lens with a rotating modifying spindle, one would:



A. Polish the posterior surface of the rigid lens

B. Polish the mid peripheral anterior surface

C. Polish the central anterior surface

D. Polish the peripheral anterior surface



The answer is A.



The keratometer readings indicate the need for a spherical back surface, which would rule out the use of
a bitoric lens. A soft spherical lens would not correct the moderate amount of refractive astigmatism that
is present, nor would the spherical rigid gas permeable lens. A front surface toric RGP would best meet
this patient's needs since it has a spherical back surface, but has a toric front surface which would
correct the residual astigmatism. - Answer 7. Which lens design would provide the best visual acuity for
a patient with the following information?

K's 42.00@ 180/ 42.50@90

Rx -6.75 +1.75 cx 90



A. Front surface toric rigid gas permeable

, B. Spherical rigid gas permeable

C. Soft sphere

D. Bitoric rigid gas permeable



The answer is A.



The wetting angle of a rigid gas permeable material describes how a fluid spreads over the surface. It is
important to remember, however, that wetting angle is a description of the material outside of the
patient's natural ocular environment. Within minutes of insertion, a rigid lens is encapsulated in the
natural tear mucin and the wetting angle of the material is no longer important. - Answer 8. Which of
the following describes the angle that the edge of a bead of water makes with the surface of a plastic?



A. Wetting angle

B. Surface angle

C. Bead angle

D. Reflection angle



The answer is B.



The back surface of a rigid lens will usually correct only the astigmatism that is found on the surface of
the cornea. Therefore, when there is significantly more astigmatism in the refraction than on the surface
of the cornea, residual astigmatism is anticipated. - Answer 9. If a patient has 1.50 D of refractive
cylinder and keratometer readings of 44.00@ 180/ 44 .50 @ 90, a spherical rigid gas permeable lens will:



A. Give the patient their best correctable vision

B. Usually result in residual astigmatism

C. Fit poorly

D. Be uncomfortable



The answer is C.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TestSolver9 Webster University
View profile
Follow You need to be logged in order to follow users or courses
Sold
756
Member since
2 year
Number of followers
125
Documents
24917
Last sold
3 days ago
TESTSOLVER9 STORE

TOPNOTCH IN LEARNING MATERIALS,(EXAMS,STUDYGUIDES NOTES ,REVIEWS,FLASHCARDS ,ALL SOLVED AND PACKAGED.OUR STORE MAKE YOUR EDUCATION JOURNEY EFFICIENT AND EASY.WE ARE HERE FOR YOU FEEL FREE TO REACH US OUT .

3.6

133 reviews

5
60
4
19
3
22
2
9
1
23

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions