100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

AWWA practice test study guide Questions and Answers Scored A+

Rating
-
Sold
-
Pages
19
Grade
A+
Uploaded on
13-09-2024
Written in
2024/2025

AWWA practice test study guide Questions and Answers Scored A+ A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT SHALL INCLUDE ALL OF THE FOLLOWING INFORMATION EXCEPT THE: A) ADDRESS OF THE INSTALLATIONB) SERIAL NUMBER OF THE ASSEMBLY C) TEST RESULTS OF CHECK VALVE NUMBER ONE (1) D) TEST RESULTS OF CHECK VALVE NUMBER TWO (2) E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING THE BY-PASS LINE OF AN APPROVED BACKFLOW PREVENTION ASSEMBLY MUST CONTAIN AN APPROVED ASSEMBLY OF EQUAL: A) CORROSION RESISTANCE B) FLOW CAPACITY C) PROTECTION D) SIZE E) TEMPERATURE RATING C) PROTECTION AN ATMOSPHERIC TYPE VACUUM BREAKER SHALL NOT BE SUBJECTED TO WATER PRESSURE FOR PERIODS THAN ______ HOURS. A) SIX (6) B) EIGHT (8) C) TWELVE (12) D) TWENTY-FOUR (24) E) NONE OF THE ABOVE C) TWELVE (12) IT IS POSSIBLE FOR A PERFECT VACUUM AT SEA LEVEL TO RAISE WATER IN A PIPE APPROXIMATELY _________ FEET. A) TWENTY-FIVE (25) B) THIRTY (30) C) THIRTY-TWO (32) D) THIRTY-FOUR (34) E) THIRTY-SIX (36) D) THIRTY-FOUR (34) WHAT IS THE MOST DESIRABLE PLACE TO INSTALL A BACKFLOW PREVENTION DEVICE AND/OR ASSEMBLY? A) IN A REINFORCED CONCRETE PIT B) IN AN ACCESSIBLE LOCATION ABOVE GROUND C) UNDERGROUND, WITH A MINIMUM OF TWELVE (12) INCHES OF COVER D) AT OR ABOVE CEILING HEIGHT, TO PROTECT IT FROM VANDALISM E) BEHIND THE BOILER OR EQUIPMENT SERVED, SO IT CAN BE WORKED ON WHEN THE EQUIPMENT IS REMOVED B) IN AN ACCESSIBLE LOCATION ABOVE GROUND WHICH OF THE FOLLOWING CONDITIONS COULD RESULT IN WATER CONTAMINATION THROUGH A CROSS-CONNECTION? A) A VACUUM CREATED BY THE IMPROPER USE OF WATER HAMMER ARRESTERS B) THE USE OF SELF CLOSING LAVATORY FAUCETS C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE WATER SUPPLY TO DRAIN D) A VACUUM CREATED BY THE USE OF QUICK CLOSING VALVES ON THE LOWER FLOORS OF A BUILDING EXCEEDING TEN (10) FLOORS IN HEIGHT E) THE INSTALLATION OF WATER CONSERVING FIXTURES, INTO A BUILDING DESIGNED PRIOR TO THEIR REQUIRED US C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE WATER SUPPLY TO DRAIN WHAT IS ANOTHER TERM THAT DESCRIBES WATER QUALITY AS A HEALTH HAZARD RESULTING FROM BACKFLOW? A) ISOLATION B) CONTAMINATION C) CROSS-CONNECTION D) POLLUTION E) CONTAINED B) CONTAMINATION THE VENTURI EFFECT STATES THAT WHEN THE WATER VELOCITY WITHIN THE PIPE INCREASES, THE PRESSURE: A) WILL INCREASE PROPORTIONATELY B) WILL REMAIN CONSTANT C) COMPRESSES EXCESS VOLUMES OF WATER D) DECREASES E) CREATES BACKPRESSURE D) DECREASES THE DEGREE OF HAZARD IS: A) THE ACCEPTABLE TEMPERATURE RANGE OF A NON-POTABLE WATER SOURCE B) THE ANGLE OF THE BACKFLOW PREVENTER C) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE D) DISTANCE BETWEEN THE CROSS-CONNECTION AND THE BACKFLOW PREVENTER E) THE ENGINEER’S SPECIFIED ELEVATION OF NON-POTABLE PIPING C) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE BACKFLOW MAY BE DESCRIBED AS EITHER: A) BACKPRESSURE OR BACKSIPHONAGE B) CONTAMINATION OR POLLUTION C) CONTAINMENT AND ISOLATION D) DIRECT AND/OR INDIRECT E) HIGH TEMPERATURE OR LOW TEMPERATURE A) BACKPRESSURE OR BACKSIPHONAGE THE FEDERAL LAW PLACING RESPONSIBILITY FOR THE PROTECTION OF THE PUBLIC WATER SUPPLY ON THE PURVEYOR OF WATER IS THE: A) ENVIRONMENTAL PROTECTION AGENCY’S PRIMARY DRINKING WATER REGULATIONS B) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS C) SAFE DRINKING WATER ACT D) FOOD AND DRUG ADMINISTRATION’S UNIFORM PLUMBING CODE E) CLEAN WATER ACT C) SAFE DRINKING WATER ACT HOW MANY INCHES MUST A PRESSURE TYPE VACUUM BREAKER ASSEMBLY BE INSTALLED ABOVE ALL DOWNSTREAM PIPING? A) SIX (6) B) TWELVE (12) C) EIGHTEEN (18) D) TWENTY-FOUR (24) E) ONE (1) B) TWELVE (12) A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY WILL PROTECT THE POTABLE WATER SUPPLY FROM: A) NON-HEALTH HAZARD – BACKSIPHONAGE B) NON-HEALTH HAZARD – BACKPRESSURE C) NON-HEALTH HAZARD – BACKPRESSURE AND BACKSIPHONAGE D) HEALTH HAZARD – BACKSIPHONAGE E) HEALTH HAZARD – BACKPRESSURE C) NON-HEALTH HAZARD – BACKPRESSURE AND BACKSIPHONAGE HOW MANY INCHES MUST AN ATMOSPHERIC VACUUM BREAKER BE INSTALLED ABOVE ALL DOWNSTREAM PIPING AND HIGHEST OPENING? A) SIX (6) B) NINE (9) C) TWELVE (12) D) EIGHTEEN (18) E) ONE (1) A) SIX (6) AN ATMOSPHERIC VACUUM BREAKER IS INSTALLED TO PROTECT AGAINST: A) BACKPRESSURE – NON-HEALTH HAZARD CONDITIONS ONLY B) BACKPRESSURE – HEALTH HAZARD CONDITIONS ONLY C) BACKSIPHONAGE – NON-HEALTH HAZARD CONDITIONS ONLY D) BACKSIPHONAGE – HEALTH HAZARD CONDITIONS ONLY E) BACKSIPHONAGE – HEALTH HAZARD OR NON-HEALTH HAZARD CONDITIONS E) BACKSIPHONAGE – HEALTH HAZARD OR NON-HEALTH HAZARD CONDITIONS THE TERM “APPROVED REDUCED PRESSURE PRINCIPLE ASSEMBLY”, APPLIES TO AN ASSEMBLY WITH TWO SHUT-OFF VALVES, FOUR TEST COCKS AND: A) TWO CHECK VALVES AND AN AIR INLET VALVE B) TWO APPROVED CHECK VALVES AND AN AIR INLET VALVE C) TWO APPROVED CHECK VALVES AND A PRESSURE RELIEF VALVE D) TWO APPROVED CHECK VALVES AND A DIFFERENTIAL PRESSURE RELIEF Valve E) TWO APPROVED CHECK VALVES AND A PRESSURE REGULATING VALVE D) TWO APPROVED CHECK VALVES AND A DIFFERENTIAL PRESSURE RELIEF Valve IT IS REQUIRED THAT THE TEST GAUGE BE TESTED FOR ACCURACY AT LEAST: A) MONTHLY B) QUARTERLY C) SEMI-ANNUALLY D) ANNUALLY E) AT THE TIME OF PURCHASE AND PRIOR TO EACH USE FOR TESTING D) ANNUALLY UNDERSIZED WATER PIPING CARRYING WATER AT HIGH VELOCITY CAN CAUSE BACKSIPHONAGE DUE TO: A) THE VACUUM EFFECT B) THE PIVOT EFFECT C) THE MARGINAL EFFECT D) THE ASPIRATOR EFFECT E) THE VELOCITY EFFECT D) THE ASPIRATOR EFFECT AN AIR GAP SEPARATION IS MEASURED FROM THE OUTLET OF THE DISCHARGE PIPE, TO THE: A) FIXTURE DRAIN PLUG B) INLET OF THE SUPPLY C) LEVEL OF THE LIQUID D) FLOOD LEVEL RIM E) NONE OF THE ABOVE D) FLOOD LEVEL RIM THE MINIMUM TYPE OF CONTAINMENT PROTECTION FOR A NON-HEALTH HAZARD, NON-CHEMICAL FIRE SPRINKLER SYSTEM IS A(N): A) ATMOSPHERIC VACUUM BREAKER B) DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER C) PRESSURE VACUUM BREAKER ASSEMBLY D) REDUCED PRESSURE DETECTOR ASSEMBLY E) ALL OF THE ABOVE B) DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER THE TYPE OF PROTECTION REQUIRED FOR A CLOSED LOOP HEATING SYSTEM CONTAINING CHEMICALS IS: A) REDUCED PRESSURE PRINCIPLE ASSEMBLY B) DOUBLE CHECK VALVE ASSEMBLY C) PRESSURE VACUUM BREAKER ASSEMBLY D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER E) ALL OF THE ABOVE A) REDUCED PRESSURE PRINCIPLE ASSEMBLY FOR CONTAINMENT PROTECTION IN A NON-HEALTH HAZARD SITUATION, THE MINIMUM PROTECTION REQUIRED SHALL BE: A) REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER B) TWO (2) SINGLE CHECK VALVES IN SERIES C) DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY D) ATMOSPHERIC VACUUM BREAKER E) NONE OF THE ABOVE C) DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY WATER CONTINUOUSLY LEAKING FROM TEST COCK #2 DURING A TEST PROCEDURE OF A PRESSURE VACUUM BREAKER ASSEMBLY IS PROBABLY CAUSED BY A LEAKING: A) AIR INLET VALVE B) TEST COCK #1 C) INLET SHUT-OFF VALVE #1 D) OUTLET SHUT-OFF VALVE #2 E) TEST COCK #2 C) INLET SHUT-OFF VALVE #1 THE REQUIRED BACKFLOW PREVENTION ASSEMBLY FOR A FIRE SUPPRESSION SYSTEM CONTAINING CHEMICALS IS: A) REDUCED PRESSURE DETECTOR ASSEMBLY OR REDUCED PRESSURE PRINCIPLE ASSEMBLY B) DOUBLE CHECK DETECTOR ASSEMBLY OR DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY C) PRESSURE VACUUM BREAKER ASSEMBLY D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER E) NONE OF THE ABOVE A) REDUCED PRESSURE DETECTOR ASSEMBLY OR REDUCED PRESSURE PRINCIPLE ASSEMBLY THE REQUIRED TYPE OF BACKFLOW PROTECTION FOR A CLOSED LOOP PIPING SYSTEM CONTAINING GLYCOL IS: A) DOUBLE CHECK VALVE ASSEMBLY B) REDUCED PRESSURE PRINCIPLE ASSEMBLY C) ATMOSPHERIC VACUUM BREAKER D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER E) NONE OF THE ABOVE B) REDUCED PRESSURE PRINCIPLE ASSEMBLY

Show more Read less
Institution
AWWA
Course
AWWA










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
AWWA
Course
AWWA

Document information

Uploaded on
September 13, 2024
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

AWWA practice test study guide
Questions and Answers Scored A+

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND
MAINTENANCE REPORT SHALL INCLUDE ALL OF THE FOLLOWING
INFORMATION EXCEPT THE:
A) ADDRESS OF THE INSTALLATIONB) SERIAL NUMBER OF THE ASSEMBLY
C) TEST RESULTS OF CHECK VALVE NUMBER ONE (1)
D) TEST RESULTS OF CHECK VALVE NUMBER TWO (2)
E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING – answer E)
DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING

THE BY-PASS LINE OF AN APPROVED BACKFLOW PREVENTION ASSEMBLY
MUST CONTAIN AN APPROVED ASSEMBLY OF EQUAL:
A) CORROSION RESISTANCE
B) FLOW CAPACITY
C) PROTECTION
D) SIZE
E) TEMPERATURE RATING – answer C) PROTECTION

AN ATMOSPHERIC TYPE VACUUM BREAKER SHALL NOT BE SUBJECTED TO
WATER PRESSURE FOR PERIODS THAN ______ HOURS.
A) SIX (6)
B) EIGHT (8)
C) TWELVE (12)
D) TWENTY-FOUR (24)
E) NONE OF THE ABOVE - answerC) TWELVE (12)

IT IS POSSIBLE FOR A PERFECT VACUUM AT SEA LEVEL TO RAISE WATER IN A
PIPE APPROXIMATELY _________ FEET.
A) TWENTY-FIVE (25)
B) THIRTY (30)
C) THIRTY-TWO (32)
D) THIRTY-FOUR (34)
E) THIRTY-SIX (36) - answerD) THIRTY-FOUR (34)

WHAT IS THE MOST DESIRABLE PLACE TO INSTALL A BACKFLOW PREVENTION
DEVICE AND/OR ASSEMBLY?
A) IN A REINFORCED CONCRETE PIT
B) IN AN ACCESSIBLE LOCATION ABOVE GROUND
C) UNDERGROUND, WITH A MINIMUM OF TWELVE (12) INCHES OF COVER

,D) AT OR ABOVE CEILING HEIGHT, TO PROTECT IT FROM VANDALISM
E) BEHIND THE BOILER OR EQUIPMENT SERVED, SO IT CAN BE WORKED ON
WHEN THE EQUIPMENT IS REMOVED - answerB) IN AN ACCESSIBLE LOCATION
ABOVE GROUND

WHICH OF THE FOLLOWING CONDITIONS COULD RESULT IN WATER
CONTAMINATION THROUGH A CROSS-CONNECTION?
A) A VACUUM CREATED BY THE IMPROPER USE OF WATER HAMMER
ARRESTERS
B) THE USE OF SELF CLOSING LAVATORY FAUCETS
C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND ALLOWING THE
WATER SUPPLY TO DRAIN
D) A VACUUM CREATED BY THE USE OF QUICK CLOSING VALVES ON THE
LOWER FLOORS OF A BUILDING EXCEEDING TEN (10) FLOORS IN HEIGHT
E) THE INSTALLATION OF WATER CONSERVING FIXTURES, INTO A BUILDING
DESIGNED PRIOR TO THEIR REQUIRED US - answerC) TURNING OFF SERVICE
TO A MULTI-STORY BUILDING AND ALLOWING THE WATER SUPPLY TO DRAIN

WHAT IS ANOTHER TERM THAT DESCRIBES WATER QUALITY AS A HEALTH
HAZARD RESULTING FROM BACKFLOW?
A) ISOLATION
B) CONTAMINATION
C) CROSS-CONNECTION
D) POLLUTION
E) CONTAINED - answerB) CONTAMINATION

THE VENTURI EFFECT STATES THAT WHEN THE WATER VELOCITY WITHIN THE
PIPE INCREASES, THE PRESSURE:\
A) WILL INCREASE PROPORTIONATELY
B) WILL REMAIN CONSTANT
C) COMPRESSES EXCESS VOLUMES OF WATER
D) DECREASES
E) CREATES BACKPRESSURE - answerD) DECREASES

THE DEGREE OF HAZARD IS:
A) THE ACCEPTABLE TEMPERATURE RANGE OF A NON-POTABLE WATER
SOURCE
B) THE ANGLE OF THE BACKFLOW PREVENTER
C) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE
D) DISTANCE BETWEEN THE CROSS-CONNECTION AND THE BACKFLOW
PREVENTER
E) THE ENGINEER'S SPECIFIED ELEVATION OF NON-POTABLE PIPING -
answerC) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE

BACKFLOW MAY BE DESCRIBED AS EITHER:
A) BACKPRESSURE OR BACKSIPHONAGE

, B) CONTAMINATION OR POLLUTION
C) CONTAINMENT AND ISOLATION
D) DIRECT AND/OR INDIRECT
E) HIGH TEMPERATURE OR LOW TEMPERATURE - answerA) BACKPRESSURE
OR BACKSIPHONAGE

THE FEDERAL LAW PLACING RESPONSIBILITY FOR THE PROTECTION OF THE
PUBLIC WATER SUPPLY ON THE PURVEYOR OF WATER IS THE:
A) ENVIRONMENTAL PROTECTION AGENCY'S PRIMARY DRINKING WATER
REGULATIONS
B) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS
C) SAFE DRINKING WATER ACT
D) FOOD AND DRUG ADMINISTRATION'S UNIFORM PLUMBING CODE
E) CLEAN WATER ACT - answerC) SAFE DRINKING WATER ACT

HOW MANY INCHES MUST A PRESSURE TYPE VACUUM BREAKER ASSEMBLY
BE INSTALLED ABOVE ALL DOWNSTREAM PIPING?
A) SIX (6)
B) TWELVE (12)
C) EIGHTEEN (18)
D) TWENTY-FOUR (24)
E) ONE (1) - answerB) TWELVE (12)

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY WILL PROTECT THE
POTABLE WATER SUPPLY FROM:
A) NON-HEALTH HAZARD - BACKSIPHONAGE
B) NON-HEALTH HAZARD - BACKPRESSURE
C) NON-HEALTH HAZARD - BACKPRESSURE AND BACKSIPHONAGE
D) HEALTH HAZARD - BACKSIPHONAGE
E) HEALTH HAZARD - BACKPRESSURE - answerC) NON-HEALTH HAZARD -
BACKPRESSURE AND BACKSIPHONAGE

HOW MANY INCHES MUST AN ATMOSPHERIC VACUUM BREAKER BE
INSTALLED ABOVE ALL DOWNSTREAM PIPING AND HIGHEST OPENING?
A) SIX (6)
B) NINE (9)
C) TWELVE (12)
D) EIGHTEEN (18)
E) ONE (1) - answerA) SIX (6)

AN ATMOSPHERIC VACUUM BREAKER IS INSTALLED TO PROTECT AGAINST:
A) BACKPRESSURE - NON-HEALTH HAZARD CONDITIONS ONLY
B) BACKPRESSURE - HEALTH HAZARD CONDITIONS ONLY
C) BACKSIPHONAGE - NON-HEALTH HAZARD CONDITIONS ONLY
D) BACKSIPHONAGE - HEALTH HAZARD CONDITIONS ONLY

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
julianah420 Phoenix University
View profile
Follow You need to be logged in order to follow users or courses
Sold
658
Member since
3 year
Number of followers
324
Documents
34114
Last sold
6 days ago
NURSING,TESTBANKS,ASSIGNMENT,AQA AND ALL REVISION MATERIALS

On this page, you find all documents, package deals, and flashcards offered by seller julianah420

4.3

149 reviews

5
101
4
20
3
8
2
5
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions