Maine Gas Exam Practice Questions and Answers Minimum vertical height for a Type B-W gas vent above the bottom of a wall furnace? - Answer️️ -12 Feet NFPA 54 12.7.2(3) Minimum thickness of a steel striker barrier for gas tubing protection? - Answer️️ -0.0508" NFPA 54 7.3.4 What is the maximum temp that a clay flue liner must be able to withstand without cracking? - Answer️️ -1,800 degrees F NFPA 54 12.6.1.3 Combustion air obtained from indoors on the same story shall have a minimum of... - Answer️️ -Two openings. Each opening 1in squared/1000 btu/hr of all appliances in space NFPA 54 9.3.2.3 ©SOPHIABENNET@ Thursday, August 22, 2024 10:21 AM 2 When gas is being supplied by a manifold located in a remote area, what is the maximum distance the shutoff valve at the manifold can be located from the appliance? - Answer️️ -50 feet NFPA 54 9.6.4.3 What reference standard covers the storage of liquid propane gas? - Answer️️ -NFPA 58 A service station is being built with one boiler 28 feet away from the meter that uses natural gas; all other equipment is electric. What size K or L semi- rigid copper tubing should be installed to supply 205 cu. ft. of gas per hour with an inlet pressure less than 2 psi, pressure drop of 0.3 in. W.C. and a specific gravity of 0.60? - Answer️️ -1 " Maximum distance a gas shut-off valve can be installed from the equipment it serves? - Answer️️ -6 feet NFPA 54 9.6.4.1 Maximum distance off the ceiling of the room shall an indoor combustion air opening be installed? - Answer️️ -12" NFPA 54 9.3.2.3 ©SOPHIABENNET@ Thursday, August 22, 2024 10:21 AM 3 What is the minimum required clearance for an unlisted pool heater on all sides and rear? - Answer️️ -12" NFPA 54 10.21.2(3) Flanges used for gas piping shall have gaskets made of an approved material designed to withstand temperatures, pressure and chemical constituents of the gas. Which of the following gasket materials is not acceptable? - Answer️️ -Rubber NFPA 54 5.6.11 When corrosive or flammable fumes or gases are present near appliances, a safe disposal method shall be provided. All of the following are considered flammable or corrosive EXCEPT?! - Answer️️ -Anhydrous Citric Acid When a mechanical appliance is installed in an excavation deeper than 12", what shall the excavation be lined with? - Answer️️ -Copper pan, concrete pit, or other suitable material NFPA 54 10.11.9 Which type of regulator is used in series with an another pressure regulator for the purpose of automatically taking over in an emergency the ©SOPHIABENNET@ Thursday, August 22, 2024 10:21 AM 4 control of the pressure down stream in case the pressure tends to exceed a set maximum? - Answer️️ -Monitoring NFPA 54 3.3.88.4 When more than 2 90° elbow's are required in a vent connector, the maximum capacity of the connector shall be reduced for ea

Show more Read less
Institution
Course










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Course

Document information

Uploaded on
August 29, 2024
Number of pages
28
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©SOPHIABENNET@2024-2025 Thursday, August 22, 2024 10:21 AM




Maine Gas Exam Practice Questions and Answers

Minimum vertical height for a Type B-W gas vent above the bottom of a
wall furnace? - Answer✔️✔️-12 Feet



NFPA 54 12.7.2(3)

Minimum thickness of a steel striker barrier for gas tubing protection? -
Answer✔️✔️-0.0508"



NFPA 54 7.3.4

What is the maximum temp that a clay flue liner must be able to withstand
without cracking? - Answer✔️✔️-1,800 degrees F



NFPA 54 12.6.1.3

Combustion air obtained from indoors on the same story shall have a
minimum of... - Answer✔️✔️-Two openings. Each opening 1in
squared/1000 btu/hr of all appliances in space



NFPA 54 9.3.2.3




1

, ©SOPHIABENNET@2024-2025 Thursday, August 22, 2024 10:21 AM




When gas is being supplied by a manifold located in a remote area, what is
the maximum distance the shutoff valve at the manifold can be located
from the appliance? - Answer✔️✔️-50 feet



NFPA 54 9.6.4.3

What reference standard covers the storage of liquid propane gas? -
Answer✔️✔️-NFPA 58

A service station is being built with one boiler 28 feet away from the meter
that uses natural gas; all other equipment is electric. What size K or L semi-
rigid copper tubing should be installed to supply 205 cu. ft. of gas per hour
with an inlet pressure less than 2 psi, pressure drop of 0.3 in. W.C. and a
specific gravity of 0.60? - Answer✔️✔️-1 "

Maximum distance a gas shut-off valve can be installed from the
equipment it serves? - Answer✔️✔️-6 feet



NFPA 54 9.6.4.1

Maximum distance off the ceiling of the room shall an indoor combustion
air opening be installed? - Answer✔️✔️-12"



NFPA 54 9.3.2.3



2

, ©SOPHIABENNET@2024-2025 Thursday, August 22, 2024 10:21 AM




What is the minimum required clearance for an unlisted pool heater on all
sides and rear? - Answer✔️✔️-12"



NFPA 54 10.21.2(3)

Flanges used for gas piping shall have gaskets made of an approved
material designed to withstand temperatures, pressure and chemical
constituents of the gas. Which of the following gasket materials is not
acceptable? - Answer✔️✔️-Rubber



NFPA 54 5.6.11

When corrosive or flammable fumes or gases are present near appliances, a
safe disposal method shall be provided. All of the following are considered
flammable or corrosive EXCEPT?! - Answer✔️✔️-Anhydrous Citric Acid

When a mechanical appliance is installed in an excavation deeper than 12",
what shall the excavation be lined with? - Answer✔️✔️-Copper pan,
concrete pit, or other suitable material



NFPA 54 10.11.9

Which type of regulator is used in series with an another pressure
regulator for the purpose of automatically taking over in an emergency the



3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SophiaBennett Howard Community College
Follow You need to be logged in order to follow users or courses
Sold
130
Member since
1 year
Number of followers
5
Documents
8034
Last sold
2 days ago
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 reviews

5
10
4
5
3
7
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions