AVIXA CTS-D: Structural and Mechanical
Considerations Exam Questions With
Correct Answers
EMP - Energy Management Plan - answer✔✔Identifies Energy Reduction Points
EMM - Energy Management Manager - answer✔✔A role that provides leadership and
management of the system
Wiring Diagram in terms of Energy management - answer✔✔illustrates how power to AV
components is controlled and monitored and how the energy management system is connected to
the AV system
Visual Display in terms of Energy Management - answer✔✔Shows users and management the
continuous power usage of the AV system
Use of Automated Devices and Power-State Changes in terms of energy management -
answer✔✔Ensure the AV system is energy-efficient
Method for Continuous Power Measurement - answer✔✔Collect power consumption data
End-user Operation Training - answer✔✔leads to understanding, participation, and behavior
modification
Tree ideas to the energy management standard - answer✔✔Data collection, automation,
education and training
How many requirements are there in the ANSI/INFOCOMM 4 :2012 Energy management
standard - answer✔✔7
How many design considerations are needed to achieve the ANSI/INFOCOMM 4 :2012 Energy
management standard - answer✔✔21
Wet Systems - answer✔✔fire protection systems that use water that is always under pressur
Dry Systems - answer✔✔do not have water constantly present in the system and are pressurized
by the fire department in the event of a fire.
, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM
Chemical Systems - answer✔✔Replace the room air with fire inhibiting gas, such as halon, CO2,
or halocarbon agents (that contain chlorine, fluorine, or iodine either individually or in some
combination).
Inert Gas Systems - answer✔✔Designed to reduce the ambient oxygen concentration in a
protected space to between 10 -14%, a level that is breathable but will not support flaming
combustion. These systems use inert gases such as argon and nitrogen, either as mixtures or
alone.
What to do when firestop is in your path. - answer✔✔Scrape off as little firestop as necessary,
and make sure you replace it immediately.
HVAC system basic functionality - answer✔✔1. Extract heat to and from the environment.
2. Extract heat to and from the conditioned spaces.
3. Move air throughout the conditioned spaces.
HVAC Background noise sources - answer✔✔Fans
Diffusers
Ducts
Vibration - answer✔✔Another source of noise that can be caused by HVAC systems
Should diffusers be by the presenter area? - answer✔✔Yes, to keep presenter cool
Return Air Plenum - answer✔✔the open cavity above the visible ceiling as a pathway for
breathable air. Air gets recycled via this space to the ventilation system
Styles of AV racks - answer✔✔Wall mounted, Fixed, Built in, Portable, Portable Shock Mount
Standard Equipment Rack space width - answer✔✔19 in (48 cm)
Rack unit height - answer✔✔1.75 in
Equipment Rack typical depth range - answer✔✔12 to 32+ in
Eye Height Standing for AV Rack in RU - answer✔✔35 RU (61")
Maximum patch panel height in Rack - answer✔✔31 RU (54")
Seated eye height in RU - answer✔✔24 RU (42")