100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

CT Registry Review Questions with 100% Verified Correct Answers

Rating
-
Sold
-
Pages
64
Grade
A+
Uploaded on
19-08-2024
Written in
2024/2025

CT Registry Review Questions with 100% Verified Correct Answers 1. Which of the following statements is false? a. The elimination of superimposed structures is a distinct advantage of CT over plain film imaging. b. CT images possess superior quality. c. Contrast resolution is approximately 10x better with CT compared to plain film imaging. d. Spatial resolution is approximately 10x better with CT compared to plain film imaging. - Correct Answer d 2. Which type of beam coverage will result in the greatest production of scatter radiation? a. Fan beam b. Pencil beam c. Area beam d. Cone beam - Correct Answer d Which type of beam coverage is typical of SDCT systems? a. Fan beam b. Pencil beam c. Area beam d. Cone beam - Correct Answer a Which type of beam coverage is typical of MDCT systems? a. Fan beam b. Pencil beam

Show more Read less
Institution
CT REGISTRY
Course
CT REGISTRY











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CT REGISTRY
Course
CT REGISTRY

Document information

Uploaded on
August 19, 2024
Number of pages
64
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

CT Registry Review Questions with 100%
Verified Correct Answers
1. Which of the following statements is false?



a. The elimination of superimposed structures is a distinct advantage of CT over plain film

imaging.



b. CT images possess superior quality.



c. Contrast resolution is approximately 10x better with CT compared to plain film imaging.



d. Spatial resolution is approximately 10x better with CT compared to plain film imaging. - Correct
Answer d



2. Which type of beam coverage will result in the greatest production of scatter radiation?



a. Fan beam

b. Pencil beam

c. Area beam

d. Cone beam - Correct Answer d



Which type of beam coverage is typical of SDCT systems?



a. Fan beam

b. Pencil beam

c. Area beam

d. Cone beam - Correct Answer a



Which type of beam coverage is typical of MDCT systems?



a. Fan beam

,b. Pencil beam

c. Area beam

d. Cone beam - Correct Answer d



"Translate-Rotate" is in reference to which of the following generations of CT geometries?



i. First

ii. Second

iii. Third

iv. Fourth



a. 1 thru 4

b. 1&2only

c. 3 only

d. 4 only - Correct Answer b



Which of the following structures possesses the ability to attenuate radiation the greatest?



a. Air

b. Muscle

c. Bone

d. Soft tissue - Correct Answer c



Which of the following structures is represented by the highest Hounsfield Unit?



a. Air

b. Muscle

c. Bone

d. Soft tissue - Correct Answer c



Which of the following HU values would be typical of a metallic pacemaker?

,a. 2000

b. 1000

c. -500

d. -2500 - Correct Answer a



The process in CT by which different tissue attenuation values are averaged to produce one less
accurate pixel reading is most likely defined as which of the following?



a. Interpolation

b. Extrapolation

c. Volume averaging

d. Beam hardening - Correct Answer c



Which of the following pieces of CT hardware is principally responsible for determining slice
thickness when the system is SDCT?



a. Pre-detector collimator

b. Pre-patient collimator

c. The cone beam collimator

d. The fan beam collimator - Correct Answer b



From the choices below, please select the best way to minimize the problem associated with Partial
Volume Averaging.



a. Select an alternative algorithm

b. Increase the slice thickness

c. Decrease the slice thickness

d. Increase procedure mA - Correct Answer c



Segmentation and averaging of the data results in what kind of data?



1. scan data

, 2. Image data

3. Raw data

a. 2 only

b. 3 only

c. 1&3only d. 1&2only - Correct Answer a



As associated with which of the following, does raw data become image data?



a. The detector system

b. The ADC

c. The DAS

d. The voxel - Correct Answer b



Which imaging plane divides the body into equal anterior and posterior portions?



a. the MSP

b. the MCP

c. the Axial

d. the Oblique - Correct Answer b



Which of the following is NOT housed in the gantry?



1. X-ray source

2. Cooling system

3. Generator

4. Slip ring system

5. Collimation system

6. Detector system



a. 3&6only

b. 1, 3 & 6 only

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Winfred West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
762
Member since
3 year
Number of followers
473
Documents
7387
Last sold
3 days ago
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

158 reviews

5
78
4
28
3
27
2
8
1
17

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions