100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

CT REGISTRY SAFETY QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
18-08-2024
Written in
2024/2025

CT REGISTRY SAFETY QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

Institution
CT REGISTRY
Course
CT REGISTRY









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
CT REGISTRY
Course
CT REGISTRY

Document information

Uploaded on
August 18, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

CT REGISTRY SAFETY QUESTIONS AND
ANSWERS WITH SOLUTIONS 2024
The quantity of radiation dose received by the patient from a series of CT scans is referred to as the: -
ANSWER The multiple-scan average dose (MSAD) is used to quantify the amount of exposure a patient
receives from a series of CT scans. It is calculated from the computed tomography dose index (CTDI)
through a series of equations. The quantity of radiation per scan is measured with an ionization
chamber.



Which of the following technical characteristics of a CT system does NOT directly affect patient dose? -
ANSWER Although they are beyond the control of the operator, the source-to-detector distance,
filtration, and detector efficiency of a CT system all directly affect patient dose. The selected FILAMENT
SIZE does have geometric ramifications with regard to spatial resolution. A smaller filament results in
improved spatial resolution. Patient dose is not affected by filament selection, provided that the mAs
value remains constant.



Which of the following statements most accurately describes the relationship between slice sensitivity
profile (SSP) and dose profile? - ANSWER The term slice sensitivity profile (SSP) may be used to describe
the reconstructed CT section. However, the section of tissue exposed to ionizing radiation, or dose
profile, is greater in width than the SSP.



The approximate radiation dose measured during a scan of a 100-mm-long pencil ionization chamber is
termed the: - ANSWER CTDI100 is a fixed measurement taken with a 100-mm-long pencil ionization
chamber inserted into an acrylic phantom. The CTDI100 standardizes the dose measurement from a
single axial scan and can be used to compare doses from different scan techniques.



The calculation of the average cumulative dose to each section within an acquisition of multiple sections
is termed the: - ANSWER The multiple-scan average dose (MSAD) is a calculation of the average
cumulative dose to each section within the center of a scan consisting of multiple sections. Because of
the contribution of scatter along the z-axis length of an acquisition, the MSAD for each section is higher
than the dose from an acquisition of a single section.



Automatic tube current modulation (ATCM) software is utilized by the CT system in an effort to: -
ANSWER Automatic tube current modulation (ATCM) is a form of automatic exposure control (AEC) for
CT systems. This type of software automatically DECREASES applied DOSE on the basis of the size,
density, and overall attenuation of the part being examined.

, The multiple-scan average dose (MSAD) is used to describe the: - ANSWER The multiple-scan average
dose (MSAD) is used to quantify the average cumulative dose to each section within the center of a scan
consisting of multiple sections.



Which of the following units is used to quantify absorbed dose? - ANSWER Absorbed dose describes the
amount of x-ray energy absorbed in a unit of mass. It is measured in gray (Gy).



Which of the following units is used to quantify effective dose? - ANSWER Effective dose approximates
the relative risk from exposure to ionizing radiation and is based on the radiosensitivity of a given tissue
type. It is measured in sievert (Sv).



The interaction between x-radiation and tissue that results in the complete loss of all x-ray photon
energy is called: - ANSWER Photoelectric absorption occurs when the energy of an incoming (incident) x-
ray photon is completely absorbed through the ionization of an inner-shell electron of the target atom.



Which of the following design characteristics of a CT system would result in an increased radiation dose
to the patient? 1. Decreased focus-to-isocenter distance 2. Decreased focus-to-detector distance 3.
Decreased filtration - ANSWER 1, 2, and 3



The acronym DLP is used to describe which of the following? - ANSWER Dose length product (DLP) is an
internationally accepted measure of CT patient dose defined as: DLP = MSAD × slice width (cm) × No. of
slices in scan volume.



A best practice for the use of in-plane bismuth shielding requires the: - ANSWER While in-plane bismuth
shielding is designed to be used within the acquisition range, it should be placed on the patient after the
localizer (scout) image(s) has/have been acquired.



Which of the following is the unit of radiation exposure? - ANSWER Exposure is the term used to
describe the ability of x-rays to ionize a volume of air. It is most commonly measured by the traditional
unit of roentgen (R). The International System of Units or SI unit for exposure is the coulomb per
kilogram (C/kg).



The interaction between x-radiation and tissue that results in a reduction in x-ray photon energy with a
subsequent change in photon direction is called: - ANSWER An incident x-ray photon may interact with a
target atom's outer-shell electron, transferring some energy that results in the ejection of the outer-shell

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Performance Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
314
Member since
1 year
Number of followers
36
Documents
15222
Last sold
3 days ago

Welcome To my Store My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides, Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!

Read more Read less
4.4

216 reviews

5
128
4
60
3
19
2
3
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions