100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Backflow Prevention Assembly Tester Training COMPLETE SOLUTION PACKAGE Latest Update 2024/2025

Rating
-
Sold
-
Pages
94
Grade
A+
Uploaded on
18-08-2024
Written in
2024/2025

Backflow Prevention Assembly Tester Training COMPLETE SOLUTION PACKAGE Latest Update 2024/2025

Institution
Backflow Prevention Troubleshooting
Course
Backflow prevention troubleshooting











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Backflow prevention troubleshooting
Course
Backflow prevention troubleshooting

Document information

Uploaded on
August 18, 2024
Number of pages
94
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • backflow

Content preview

Backflow Prevention
Assembly Tester
Training
COMPLETE SOLUTION
PACKAGE
Latest Update
2024/2025

,BACKFLOW PREVENTION ASSEMBLY TESTER PRACTICE EXAM

In responding to a backflow incident the water purveyor should

(A) Call the mayor

(B) Implement the emergency response plan

(C) Install a vacuum breaker

(D) Develop a good excuse - answer-Implement the emergency response plan



A mixture of air and gas is considered hazardous when the mixture exceeds what percentage of gthe
lower explosive limit

(A) 0%

(B) 3%

(C) 7%

(D) 10% - answer-10%



To exert a pressure of 1.0 psi at base of a water column the column would have to be

(A) 4.34 high

(B) 14.7 high

(C) 27.75 high

(D) 33.89 high - answer-27.75 high



A DC must be tested

(A) Upon installation

(B) Every 6 month

(C) Annually on a health hazard

(D) none of the above - answer-Upon installation



An absolute perssure of 25 psiaa (at sea level) is equal to approximately

(A) 5 psi

,(B) 10 psi

(C) 20 psi

(D) 25 psi - answer-10 psi



Dueing a field test the air inlet on PVB must open at

(A) Above 2.0 psid

(B) Below 1.0 psid

(C) Above 1.0 psid

(D) Below 2.0 psid - answer-Above 1.0 psid



A differential pressuer gauge is used to field test

(A) PVB's

(B) Dual Checks

(C) AVB's

(D) All the above - answer-PVB's



Backflow in a water supply can be caused by

(A) Backpressure only

(B) A Barometric Loop

(C) Backsiphonage only

(D) Backpressure and Backsiphonage - answer-Backpressure and Backsiphonage



A BPAT tester is required to report test information on the proper forms to the

(A) Administrative authority

(B) Manufacturer's Rep

(C) EPA

(D) None of the above - answer-Administrative authority



The relief valve opens when closing #2 shut off valve on a RP What is the most probable cause

, (A) #1 Shut off valve is open

(B) #2 Shut off valve is open

(C) #1 check is fouled open

(D) Shut off is leaking - answer-#1 check is fouled open



When field testing the #1 Check of a RP the differential pressurw shouid be

(A) Greter than or equal to 5.0 psid

(B) 3.0 psid greater than the relief valve opening point

(C) 1.0 psid in the directiom of flow

(D) Less than 5.0 psid - answer-Greter than or equal to 5.0 psid



When testing a SVB what is the firsrt test being performed

(A) The air inlet opening point

(B) The static pressure across the check valve

(C) To verify the #2shut off hold tight

(D) To check if the SVB hold water - answer-The static pressure across the check valve



When testing a PVB the air inlet opens upon closing the #1 shut off valve What is the most probable
cause

(A) Leaking #2 shut off valve

(B) Leaking #1 shut off valve

(C) Fouied air inlert

(D) Fouied check valve - answer-Leaking #2 shut off valve



A 2" AVB when used on irrigation systemsterm-15 shall be instilled

(A) 6" above all downstream piping

(B) 18" above all downstream piping

(C) 24" above all downstream piping

(D) 27 3/4" above all downstream piping - answer-6" above all downstream piping

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PatrickHaller Walden University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1381
Member since
3 year
Number of followers
1164
Documents
1832
Last sold
3 days ago
ONLINE STUDY HELP FOR NURSING STUDENTS

ACE YOUR EXAMS WITH OUR A+ GRADED STUDY HELPS

4.1

228 reviews

5
133
4
39
3
25
2
6
1
25

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions