100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Journeyman electrician exam prep With complete solution | Latest 2024/25 Rated A+

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
15-08-2024
Written in
2024/2025

Journeyman electrician exam prep With complete solution | Latest 2024/25 Rated A+

Institution
Journeyman Electrician
Course
Journeyman electrician









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman electrician
Course
Journeyman electrician

Document information

Uploaded on
August 15, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Journeyman electrician exam prep With
complete solution | Latest 2024/25 Rated
A+
What table sizes bonding jumpers for for AC systems? - 250.102(C)(1)

The NEC defines continuous load to be a load where max current on the circuit
continues for at least how many hours? - Three

To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than
how many current carrying conductors in a raceway? - Greater than three

Where in the NEC codebook would you find EMT sizes for a given size and number of
conductors? - Annex C, Table C.1

Section 210.20(A) states that the over current protection for branch circuits including
continuous loads must be greater than 100% of the noncontinuous plus ____ of the
continuous load. - 125%

Liquidtight Flexible Metal Conduit shall be fastened within of each box or other conduit
termination - Twelve inches

314.28(A)(1) states that straight pulls in pull boxes with conductors size 4 AWG or
larger, box length should be greater than or equal to times the trade diameter of the
largest conduit entering box. - Eight

Chapter 9 note 4 states conduit nipples less than 24 inches can fill to a max of their
cross sectional area - 60 percent

Table 348.22 gives the max number of insulated conductors in size _______ FMC? -
3/8 (trade size)

Guest rooms of hotels, motels, & sleeping rooms in dorms need a MIN or _____
general purpose receptacles installed that are readily accessible? - Two

When branch-circuit conductors are contained inside a ballast compartment and they
are within 3 inches of the ballast, the conductors shall have a temperature rating of at
LEAST _____.

a) 105 degrees C
b) 90 degrees C
c) 75 degrees C
d) 60 degrees C - B: 90 degrees C

, Ref: 410.68

Class _____ locations are those that are hazardous because of the presence of easily
ignitible fibers or materials producing combustible flyings.

a) I
b) II
c) III
d) IV - C: III
Ref: 500.5(D)

Class _____ locations are those in which flammable gases, flammable liquid produced
vapors, or combustible liquid produced vapors are present that are explodable. - Class
1

Class ____ locations are those that are hazardous because of combustible dust -
Class II

Conductors with _______ Insulation have a greater ampacity when used in a dry
location compared to when used in a wet location - THHW

When calculating total load for buildings and finding minimum branch circuit load, what
must be factored into the volt amps for an exterior electric sign? - Demand load (1.25)

Table C.11 and C.11(A) show conductor numbers for size for schedule 40 PVC, what is
the difference in charts? - Compact vs stranded conductors

332.30 states that type MI cable shall be supported at intervals of at least how many
feet? - Six feet

What table sizes equipment grounding conductors for specific over current devices? -
250.122

Wye is another term for what kind of systems? - Three phase

What is the equation for voltage drop? - VD=2KID/CM

In the voltage drop equation, what is the value CM, and where is it found in the NEC
codebook? - Circular mile, chapter 9, table 8

Conductors installed under at least _______ inches of concrete are considered by NEC
Section 230.6 to be outside the building. - 2 inches

Conductors installed in electrically heated floors in bathrooms, kitchens, and in hydro
massage bathtub locations shall be provided with what kind of protection? - GFCI
424.44(E)

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVEX NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
729
Member since
2 year
Number of followers
313
Documents
15137
Last sold
1 day ago
STUVATE - STUVIA USA

Our store is a comprehensive destination for buying and selling a variety of documents. we offer a vast range of documents that cater to different needs and requirements, our documents are well-researched, accurate, and of high quality, ensuring customer satisfaction. whether you are looking for legal documents, academic papers, business reports or miscellaneous documents we`ve got you covered.

3.8

112 reviews

5
43
4
29
3
23
2
7
1
10

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions